Improved corrosion performance of biodegradable magnesium in simulated inflammatory condition via drug-loaded plasma electrolytic oxidation coatings

被引:66
|
作者
Bordbar-Khiabani, Aidin [1 ,2 ]
Yarmand, Benyamin [1 ]
Sharifi-Asl, Samin [3 ,4 ]
Mozafari, Masoud [2 ]
机构
[1] MERC, Nanotechnol & Adv Mat Dept, Bioengn Res Grp, Tehran, Iran
[2] Iran Univ Med Sci, Fac Adv Technol Med, Dept Tissue Engn & Regenerat Med, Tehran, Iran
[3] Univ Calif Berkeley, Dept Mat Sci & Engn, Berkeley, CA 94720 USA
[4] Chevron ETC, Richmond, CA 94608 USA
关键词
Magnesium; Biodegradable implants; Plasma electrolytic oxidation; Drug-coated implants; Corrosion resistance; IN-VITRO BIOACTIVITY; ALLOY; RESISTANCE; SURFACE; BEHAVIOR; NANOPARTICLES; IMPLANTS; TITANIUM; RELEASE; SODIUM;
D O I
10.1016/j.matchemphys.2019.122003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Magnesium and its alloys are nowadays one of the most common biodegradable materials for orthopedic applications. Following the implantation of an orthopedic device, near the implant hydrogen peroxide and acidic environment are generated by an inflammatory reaction. In this study, a betamethasone sodium phosphate (BSP) layer as an anti-inflammatory drug was prepared on plasma electrolytic oxidation (PEO) coatings by a dipcoating process on magnesium alloys. X-ray diffraction (XRD), Fourier transformation infrared spectroscopy TIR), field emission scanning electron microscopy equipped with energy-dispersive X-ray spectroscopy (FESEM-EDX) and atomic force microscopy (AFM) were utilized for characterization studies. The results showed that the BSP layer successfully sealed the PEO coating. The corrosion resistance of the uncoated and coated samples was evaluated by electrochemical impedance spectroscopy (EIS) and potentioclynamic polarization tests in normal and simulated inflammatory conditions. During the simulated inflammation, the samples indicated an enhanced corrosion rate compared to that of normal condition. The results in the inflammatory environment showed that the corrosion resistance of the PEO/BSP coating was remarkably improved by two or three orders of magnitude, compared with uncoated Mg alloy and the PEO coating. Immersion tests show that the BSP layer significantly improves the bioactivity of PEO-coated Mg alloy in simulated body fluid (SEP). Moreover, the in vitro release behavior of drug loaded PEO coating was evaluated.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Fabrication and corrosion resistance of hybrid coatings on pure magnesium by combining plasma electrolytic boronizing with micro-arc oxidation
    Sun L.
    Ma Y.
    Li Q.-H.
    Wang S.
    Wang Z.-Y.
    Surface Technology, 2021, 50 (06): : 64 - 76
  • [42] Evolution processes of the corrosion behavior and structural characteristics of plasma electrolytic oxidation coatings on AZ31 magnesium alloy
    Chen, Dong
    Wang, Ruiqiang
    Huang, Zhiquan
    Wu, Yekang
    Zhang, Yi
    Wu, Guorui
    Li, Dalong
    Guo, Changhong
    Jiang, Guirong
    Yu, Shengxue
    Shen, Dejiu
    Nash, Philip
    APPLIED SURFACE SCIENCE, 2018, 434 : 326 - 335
  • [43] Improved Corrosion Resistance of Titanium Dioxide-Containing Plasma Electrolytic Oxidation Ceramic Coatings
    Zhao, Y. W.
    Zhang, Y.
    Xiang, N.
    Song, R. G.
    MATERIALS PERFORMANCE, 2016, 55 (11) : 36 - 39
  • [44] Effect of additives on structure and corrosion resistance of plasma electrolytic oxidation coatings on AZ91D magnesium alloy in phosphate based electrolyte
    Lv, Guo-Hua
    Chen, Huan
    Wang, Xing-Quan
    Pang, Hua
    Zhang, Gu-Ling
    Zou, Bin
    Lee, Heon-Ju
    Yang, Si-Ze
    SURFACE & COATINGS TECHNOLOGY, 2010, 205 : S36 - S40
  • [45] An Investigation into the Corrosion Behavior of MgO/ZrO2 Nanocomposite Coatings Prepared by Plasma Electrolytic Oxidation on the AZ91 Magnesium Alloy
    Eslamzadeh, Nasrollah
    Ebrahimi-Kahrizsangi, Reza
    Karbasi, Saeed
    Zarebidaki, Arman
    Gharavi, Farhad
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2017, 26 (09) : 4255 - 4264
  • [46] Improved Electrochemical Performance of Plasma Electrolytic Oxidation Coating on Titanium in Simulated Body Fluid
    S. Ahmadnia
    S. Aliasghari
    M. Ghorbani
    Journal of Materials Engineering and Performance, 2019, 28 : 4120 - 4127
  • [47] Growth Kinetics and Corrosion Protection Properties of Plasma Electrolytic Oxidation Coatings on Biodegradable Mg−2% Sr Alloy
    D. M. Lazarev
    R. G. Farrakhov
    V. R. Mukaeva
    O. B. Kulyasova
    E. V. Parfenov
    A. L. Yerokhin
    Surface Engineering and Applied Electrochemistry, 2020, 56 : 83 - 92
  • [48] Correlations between the Growth Mechanism and Corrosion Resistance of Plasma Electrolytic Oxidation Coatings on AZ31B Magnesium Alloy
    Wang, Yujie
    Zhang, Peng
    Du, Yunhui
    Zhang, Weiyi
    Cao, Haitao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (12): : 11465 - 11479
  • [49] Duty cycle influence on the corrosion behavior of coatings created by plasma electrolytic oxidation on AZ31B magnesium alloy in simulated body fluid
    Hafili, Fatemeh
    Chaharmahali, Razieh
    Babaei, Kazem
    Fattah-alhosseini, Arash
    CORROSION COMMUNICATIONS, 2021, 3 : 62 - 70
  • [50] Self-healing plasma electrolytic oxidation coatings doped with benzotriazole loaded halloysite nanotubes on AM50 magnesium alloy
    Sun, M.
    Yerokhin, A.
    Bychkova, M. Ya.
    Shtansky, D. V.
    Levashov, E. A.
    Matthews, A.
    CORROSION SCIENCE, 2016, 111 : 753 - 769