Retinal nerve fiber layer and macular inner retina measurements by spectral domain optical coherence tomograph in Indian eyes with early glaucoma

被引:84
作者
Rao, H. L. [1 ,2 ]
Babu, J. G. [1 ]
Addepalli, U. K. [1 ]
Senthil, S. [1 ]
Garudadri, C. S. [1 ]
机构
[1] LV Prasad Eye Inst, VST Glaucoma Ctr, Hyderabad 500034, Andhra Pradesh, India
[2] LV Prasad Eye Inst, Ctr Clin Epidemiol & Biostat, Hyderabad 500034, Andhra Pradesh, India
关键词
spectral domain OCT; ganglion cell complex; retinal nerve fiber layer; diagnostic accuracy; DIAGNOSTIC-ACCURACY; DISC SIZE; DISEASE SEVERITY; SCANNING AREAS; THICKNESS; PERFORMANCE; RESOLUTION; DESIGN; HEAD; BIAS;
D O I
10.1038/eye.2011.277
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the diagnostic abilities of peripapillary retinal nerve fiber layer (RNFL) and macular inner retina (MIR) measurements by spectral domain optical coherence tomography (SD-OCT) in Indian eyes early glaucoma. Methods In an observational, cross-sectional study, 125 eyes of 64 normal subjects and 91 eyes of 59 early glaucoma patients underwent RNFL and MIR imaging with SD-OCT. Glaucomatous eyes had characteristic optic nerve and RNFL abnormalities and correlating visual field defects and a mean deviation of better than or equal to -6 dB on standard automated perimetry. Areas under the receiver operating characteristic curves (AUC), sensitivities at a fixed specificity and likelihood ratios (LRs) were estimated for all RNFL and MIR parameters. Results The AUCs for the RNFL parameters ranged from 0.537 for the temporal quadrant thickness to 0.821 for the inferior quadrant RNFL thickness. AUCs for the MIR parameters ranged from 0.603 for the superior minus inferior MIR thickness average to 0.908 for ganglion cell complex focal loss volume (GCC-FLV). AUC for the best MIR parameter (GCC-FLV) was significantly better (P < 0.001) than that of the best RNFL parameter (inferior quadrant thickness). The sensitivities of these parameters at high specificity of 95%, however, were comparable (52.7% vs 58.2%). Evaluation of the LRs showed that outside normal limits results of most of the RNFL and MIR parameters were associated with large effects on the post-test probability of disease. Conclusion MIR parameters with RTVue SD-OCT were as good as the RNFL parameters to detect early glaucoma. Eye (2012) 26, 133-139; doi:10.1038/eye.2011.277; published online 11 November 2011
引用
收藏
页码:133 / 139
页数:7
相关论文
共 31 条
[11]   Empirical evidence of design-related bias in studies of diagnostic tests [J].
Lijmer, JG ;
Mol, BW ;
Heisterkamp, S ;
Bonsel, GJ ;
Prins, MH ;
van der Meulen, JHP ;
Bossuyt, PMM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (11) :1061-1066
[12]   Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Sample, PA ;
Weinreb, RN .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) :1008-1015
[13]   Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Vessani, RM ;
Susanna, R ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) :44-55
[14]   Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Weinreb, RN .
ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (06) :827-837
[15]   The effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy in glaucoma [J].
Medeiros, Felipe A. ;
Ng, Diana ;
Zangwill, Linda M. ;
Sample, Pamela A. ;
Bowd, Christopher ;
Weinreb, Robert N. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) :214-222
[16]   Spectral-domain Optical Coherence Tomography Measurement of Macular Volume for Diagnosing Glaucoma [J].
Mori, Satoshi ;
Hangai, Masanori ;
Sakamoto, Atsushi ;
Yoshimura, Nagahisa .
JOURNAL OF GLAUCOMA, 2010, 19 (08) :528-534
[17]   In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve [J].
Nassif, NA ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Yun, SH ;
Bouma, BE ;
Tearney, GJ ;
Chen, TC ;
de Boer, JF .
OPTICS EXPRESS, 2004, 12 (03) :367-376
[18]   Detection of early glaucoma with optical coherence tomography (StratusOCT) [J].
Nouri-Mahdavi, Kouros ;
Nikkhou, Kiavash ;
Hoffman, Douglas C. ;
Law, Simon K. ;
Caprioli, Joseph .
JOURNAL OF GLAUCOMA, 2008, 17 (03) :183-188
[19]   Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma [J].
Parikh, Raiul S. ;
Parikh, Shefali ;
Sekhar, G. Chandra ;
Kumar, Rajesh S. ;
Prabakaran, S. ;
Babu, J. Ganesh ;
Thomas, Ravi .
OPHTHALMOLOGY, 2007, 114 (12) :2238-2243
[20]  
RADACK KL, 1986, ARCH PATHOL LAB MED, V110, P689