摘要
Strokes cause severe impairment of hand function because of the spasticity in the affected upper extremities. Proper spasticity evaluation is critical to facilitate neural plasticity for rehabilitation after stroke. However, existing methods for measuring spasticity, e.g. Modified Ashworth Scale (MAS), highly depends on clinicians' experiences, which are subjective and lacks quantitative details. Here, we introduce the first rehabilitation actuator that objectively reflects the condition of post-stroke finger spasticity. The actuator is 3D printed with soft materials. By considering the finger and the actuator together, the spasticity, i.e. stiffness, in finger is obtained from the pressure-angle relationship. The method is validated by simulations using finite element analysis (FEA) and experiments on mannequin fingers. Furthermore, it is examined on four stroke subjects and four healthy subjects. Results show the finger stiffness increases significantly from healthy subjects to stroke subjects, particularly those with high MAS score. For patients with the same MAS score, stiffness variation can be a few times. With this soft actuator, a hand rehabilitation robot that may tell the therapeutic progress during the rehabilitation training is readily available.
引用
收藏
页数:10
相关论文
共 48 条
[31]  
Ogden R. W., 1984, Non-linear elastic deformations, DOI 10.1016/0264-682X(84)90061-3
[32]   A review of the properties and limitations of the Ashworth and modified Ashworth Scales as measures of spasticity [J].
Pandyan, AD ;
Johnson, GR ;
Price, CIM ;
Curless, RH ;
Barnes, MP ;
Rodgers, H .
CLINICAL REHABILITATION, 1999, 13 (05) :373-383
[33]   Quantitative Assessment of Hand Spasticity After Stroke: Imaging Correlates and Impact on Motor Recovery [J].
Plantin, Jeanette ;
Pennati, Gaia, V ;
Roca, Pauline ;
Baron, Jean-Claude ;
Laurencikas, Evaldas ;
Weber, Karin ;
Godbolt, Alison K. ;
Borg, Jorgen ;
Lindberg, Pavel G. .
FRONTIERS IN NEUROLOGY, 2019, 10
[34]   Modeling of Soft Fiber-Reinforced Bending Actuators [J].
Polygerinos, Panagiotis ;
Wang, Zheng ;
Overvelde, Johannes T. B. ;
Galloway, Kevin C. ;
Wood, Robert J. ;
Bertoldi, Katia ;
Walsh, Conor J. .
IEEE TRANSACTIONS ON ROBOTICS, 2015, 31 (03) :778-789
[35]  
Polygerinos P, 2013, IEEE INT C INT ROBOT, P1512, DOI 10.1109/IROS.2013.6696549
[36]  
Prosser R, 1996, J Hand Ther, V9, P378
[37]   Force myography for monitoring grasping in individuals with stroke with mild to moderate upper-extremity impairments: A preliminary investigation in a controlled environment [J].
Sadarangani G.P. ;
Jiang X. ;
Simpson L.A. ;
Eng J.J. ;
Menon C. .
Frontiers in Bioengineering and Biotechnology, 2017, 5 (AUG)
[38]   Efficacy of robot-assisted fingers training in chronic stroke survivors: a pilot randomized-controlled trial [J].
Susanto, Evan A. ;
Tong, Raymond K. Y. ;
Ockenfeld, Corinna ;
Ho, Newmen S. K. .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2015, 12
[39]   Model-based online learning and adaptive control for a "human-wearable soft robot" integrated system [J].
Tang, Zhi Qiang ;
Heung, Ho Lam ;
Tong, Kai Yu ;
Li, Zheng .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2021, 40 (01) :256-276
[40]   Spasticity after stroke: Physiology, assessment and treatment [J].
Thibaut, Aurore ;
Chatelle, Camille ;
Ziegler, Erik ;
Bruno, Marie-Aurelie ;
Laureys, Steven ;
Gosseries, Olivia .
BRAIN INJURY, 2013, 27 (10) :1093-1105