2D modeling and preliminary in vitro investigation of a prototype high gradient magnetic separator for biomedical applications

被引:21
作者
Chen, Haitao [1 ,4 ]
Kaminski, Michael D. [3 ]
Rosengart, Axel J. [1 ,2 ]
机构
[1] Univ Chicago, Pritzker Sch Med, Dept Neurol, Chicago, IL 60637 USA
[2] Univ Chicago, Pritzker Sch Med, Dept Surg, Chicago, IL 60637 USA
[3] Argonne Natl Lab, Div Chem Engn, Argonne, IL 60439 USA
[4] IIT, Dept Biomed Engn, Chicago, IL 60616 USA
关键词
magnetic separator; magnetic spheres; high gradient magnetic separation; blood detoxification; simulation;
D O I
10.1016/j.medengphy.2007.02.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High gradient magnetic separation (HGMS) of magnetic materials from fluids or waste products has many established industrial applications. However, there is currently no technology employing HGMS for ex-vivo biomedical applications, such as for the removal of magnetic drug-or toxin-loaded spheres from the human blood stream. Importantly, human HGMS applications require special design modifications as, in contrast to conventional use where magnetic,elements are permanently imbedded within the separation chambers, medical separators need to avoid direct contact between the magnetic materials and blood to reduce the risk of blood clotting and to facilitate convenient and safe treatment access for many individuals. We describe and investigate the performance of a magnetic separator prototype designed for biomedical applications. First, the capture efficiency of a prototype HGMS separator unit consisting of a short tubing segment and two opposing magnetizable fine wires along the outside of the tubing was investigated using 2D mathematical modeling. Second, the first-pass effectiveness to remove commercially available, magnetic polystyrene spheres from human blood using a single separator unit was experimentally verified. The theoretical and experimental data correlated well at low flow velocities (<5.0 cm/s) and high external magnetic fields (>0.05 T). This prototype separator unit removed >90% in a single pass of the magnetic spheres from water at mean flow velocity <= 8.0 cm/s and from blood mimic fluids (ethylene glycol-water solutions) at mean flow velocity <= 2.0 cm/s. In summary, we describe and prove the feasibility of a HGMS separator for biomedical applications. (c) 2007 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 33 条
[1]   Magnetic shielding: application to a new magnetic separator and classifier [J].
Augusto, PA ;
Augusto, P ;
Castelo-Grande, T .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 272 :2296-2298
[2]   Flow through, immunomagnetic cell separation [J].
Chalmers, JJ ;
Zborowski, M ;
Sun, LP ;
Moore, L .
BIOTECHNOLOGY PROGRESS, 1998, 14 (01) :141-148
[3]   A novel human detoxification system based on nanoscale bioengineering and magnetic separation techniques [J].
Chen, Haitao ;
Kaminski, Michael D. ;
Liu, Xianqiao ;
Mertz, Carol J. ;
Xie, Yumei ;
Torno, Michael D. ;
Rosengart, Axel J. .
MEDICAL HYPOTHESES, 2007, 68 (05) :1071-1079
[4]   Magnetizable intravascular stents for sequestration of systemically circulating magnetic nano- and microspheres [J].
Chen, HT ;
Kaminski, MD ;
Ebner, AD ;
Ritter, JA ;
Rosengart, AJ .
2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology, 2005, :286-289
[5]   Analysis of magnetic drug carrier particle capture by a magnetizable intravascular stent-2: Parametric study with multi-wire two-dimensional model [J].
Chen, HT ;
Ebner, AD ;
Kaminski, MD ;
Rosengart, AJ ;
Ritter, JA .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (01) :616-632
[6]   A new magnetic bead-based, filterless bio-separator with planar electromagnet surfaces for integrated bio-detection systems [J].
Choi, JW ;
Ahn, CH ;
Bhansali, S ;
Henderson, HT .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) :34-39
[7]   High-gradient magnetic separation of magnetic nanoclusters [J].
Ditsch, A ;
Lindenmann, S ;
Laibinis, PE ;
Wang, DIC ;
Hatton, TA .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (17) :6824-6836
[8]   Immunomagnetic T cell capture from blood for PCR analysis using microfluidic systems [J].
Furdui, VI ;
Harrison, DJ .
LAB ON A CHIP, 2004, 4 (06) :614-618
[9]   Analysis of particle transport in a magnetophoretic microsystem [J].
Furlani, EP .
JOURNAL OF APPLIED PHYSICS, 2006, 99 (02) :1-11
[10]  
GERBER R, 1994, NATO ASI SERIES E, V253