Universal Cooling of Data Centres: A CFD Analysis

被引:17
|
作者
Watson, Bryony [1 ]
Venkiteswaran, Vinod Kumar [1 ]
机构
[1] Heriot Watt Univ, Precinct 5, Putajaya 62200, Malaysia
来源
PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY | 2017年 / 142卷
关键词
Data Centre; Single-Phase Immersion Cooling; Hot Aisle Containment;
D O I
10.1016/j.egypro.2017.12.215
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
At present, cooling of data centres efficiently is proving a challenging feat for many companies. With constantly increasing server size and IT demand, combined with the ever increasing energy consciousness of the world, many cooling systems are no longer up to the task of effectively cooling these Data Centres while maintaining an energy efficient environment. A review ofjournal papers, white papers, and information from companies who manufacture data centre cooling solutions was undertaken. The literature reviewed shows that any solution to this increasing problem needs to be flexible. Investigation was carried out on two different types of cooling system which showed the most promise within the literature review. An air-cooled type (hot aisle containment air cooling) and a liquid-cooled type (single-phase liquid immersion cooling) were the two types of data centre cooling systems selected. 2D simulation of each of these systems, using ANSYS (c) Fluent 17.2 Academic, was carried out to demonstrate the flexibility of each system when rack density is increased from 15kW to 30kW. Conclusions were drawn that air was not a flexible cooling method if changes were to be made to the IT equipment, with a maximum outlet temperature of 324K (51 degrees C) for the 15kW system rising to 342K (69 degrees C) when changed to a 30kW system. It was also found that liquid immersion cooling was flexible and maintained an average outlet temperature of 298K (25 degrees C) even when the IT equipment was uprated to 30kW. (C) 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of the 9th International Conference on Applied Energy.
引用
收藏
页码:2711 / 2720
页数:10
相关论文
共 50 条
  • [41] CFD modelling of the air conditioning system for a Tier 2 Data Centre
    Pico, Paula
    Valdes, Juan Pablo
    Pinilla, Andres
    Echeverri, Adriana
    Gomez, Jessica Maria
    Ratkovich, Nicolas
    Cifuentes, Bernay
    ADVANCES IN BUILDING ENERGY RESEARCH, 2022, 16 (02) : 231 - 261
  • [42] Analyzing the Cooling Efficiency of the Thermal Environment in Data Centers
    Xu, Yongmei
    Zhang, Jingru
    Deng, Yuhui
    Du, Lan
    Jiao, Rong
    INTERNATIONAL JOURNAL OF GRID AND HIGH PERFORMANCE COMPUTING, 2014, 6 (04) : 15 - 27
  • [43] Cooling solutions in an operational data centre: A case study
    Fakhim, B.
    Behnia, M.
    Armfield, S. W.
    Srinarayana, N.
    APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) : 2279 - 2291
  • [44] Study on the operation strategy of the water cooling system in the single-phase immersion cooling data center considering cooling tower performance
    Wang, Chenxu
    Yu, Hang
    Xian, Lei
    Liu, Guoqiu
    Chen, Lei
    Tao, Wen-Quan
    ENERGY AND BUILDINGS, 2024, 324
  • [45] Modelling and developing conflict-aware scheduling on large-scale data centres
    Wang, Bin
    Chen, Chao
    He, Ligang
    Gao, Bo
    Ren, Jiadong
    Fu, Zhangjie
    Fu, Songling
    Hu, Yongjian
    Li, Chang-Tsun
    FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2018, 86 : 995 - 1007
  • [46] A decision support system for waste heat recovery and energy efficiency improvement in data centres
    Luo, Yang
    Andresen, John
    Clarke, Henry
    Rajendra, Matthew
    Maroto-Valer, Mercedes
    APPLIED ENERGY, 2019, 250 : 1217 - 1224
  • [47] Energy efficiency and renewable energy integration in data centres. Strategies and modelling review
    Oro, Eduard
    Depoorter, Victor
    Garcia, Albert
    Salom, Jaume
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 42 : 429 - 445
  • [48] Effective auto-alignment and tracking of transceivers for visible light communication in data centres
    Liu, Fulin
    Chen, Minan
    Jiang, Weibin
    Jin, Xianqing
    Xu, Zhengyuan
    BROADBAND ACCESS COMMUNICATION TECHNOLOGIES XIII, 2019, 10945
  • [49] Technoeconomic Feasibility of Wind and Solar Generation for Off-Grid Hyperscale Data Centres
    Rollinson, William
    Urquhart, Andrew
    Thomson, Murray
    ENERGIES, 2025, 18 (02)
  • [50] Optimized flexibility management enacting Data Centres participation in Smart Demand Response programs
    Cioara, Tudor
    Anghel, Ionut
    Bertoncini, Massimo
    Salomie, Loan
    Arnone, Diego
    Mammina, Marzia
    Velivassaki, Terpsichori-Helen
    Antal, Marcel
    FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2018, 78 : 330 - 342