Ex vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth

被引:41
作者
Leonardo, M. R. [1 ]
Silva, L. A. B. [1 ]
Nelson-Filho, P. [1 ]
Silva, R. A. B. [1 ]
Raffaini, M. S. G. G. [1 ]
机构
[1] Univ Sao Paulo, Dept Pediat Prevent & Community Dent, Ribeirao Preto Sch Dent, Sao Paulo, Brazil
关键词
electronic apex locators; Mini Apex Locator; primary teeth; root canal length; root canal length measurement; Root Zx II;
D O I
10.1111/j.1365-2591.2007.01366.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers' instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.
引用
收藏
页码:317 / 321
页数:5
相关论文
共 22 条
[1]   COMPARISON OF 6 FILES TO PREPARE SIMULATED ROOT CANALS .2. [J].
ALOMARI, MAO ;
DUMMER, PMH ;
NEWCOMBE, RG ;
DOLLER, R ;
HARTLES, F .
INTERNATIONAL ENDODONTIC JOURNAL, 1992, 25 (02) :67-81
[2]   Influence of embedding media on the assessment of electronic apex locators [J].
Baldi, Jarcio V. ;
Victorino, Fausto R. ;
Bernardes, Ricardo A. ;
de Moraes, Ivaldo G. ;
Bramante, Colvis M. ;
Garcia, Roberto B. ;
Bernardineli, Norberti .
JOURNAL OF ENDODONTICS, 2007, 33 (04) :476-479
[3]   Accuracy of Root Length Determination Using Tri Auto ZX and ProTaper Instruments: An In Vitro Study [J].
Carneiro, Everdan ;
Bramante, Clovis Monteiro ;
Picoli, Fabio ;
Letra, Ariadne ;
da Silva Neto, Ulisses Xavier ;
Menezes, Renato .
JOURNAL OF ENDODONTICS, 2006, 32 (02) :142-144
[4]  
Dandashi Moutaz B., 1993, Pediatric Dentistry, V15, P254
[5]   The ability of Root ZX apex locator to reduce the frequency of overestimated radiographic working length [J].
ElAyouti, A ;
Weiger, R ;
Löst, C .
JOURNAL OF ENDODONTICS, 2002, 28 (02) :116-119
[6]   RADIOGRAPHIC REPRODUCTION OF ENDODONTIC WORKING LENGTH COMPARING THE PARALLELING AND THE BISECTING-ANGLE TECHNIQUES [J].
FORSBERG, J .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1987, 64 (03) :353-360
[7]   Electronic apex locators [J].
Gordon, MPJ ;
Chandler, NP .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (07) :425-437
[8]   Accuracy of electronic apex locators in comparison to actual length - an in vivo study [J].
Haffner, C ;
Folwaczny, M ;
Galler, K ;
Hickel, R .
JOURNAL OF DENTISTRY, 2005, 33 (08) :619-625
[9]   The accuracy of electronic working length determination [J].
Hoer, D ;
Attin, T .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (02) :125-131
[10]  
Katz A, 1996, J DENT CHILD, V63, P414