Determination of 21 elements in human serum using ICP-MS with collision/reaction cell

被引:15
|
作者
Gong, Zi-Shan [1 ]
Jiang, Xue-Hui [1 ]
Sun, Chuan-Qiang [1 ]
Tian, Ya-Ping [2 ]
Guo, Guang-Hong [2 ]
Zhang, Yang-Zan [1 ]
Zhao, Xue-Hong [1 ]
Wang, Yan [1 ]
机构
[1] Tianjin Univ, Dept Precis Instrument & Optoelect Engn, 92 Weijin Rd, Tianjin 300072, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Dept Clin Biochem, Beijing 100853, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Inductively coupled plasma mass; spectrometry (ICP-MS); Collision/Reaction cell; Human serum; Marco- and ultra-trace elements; Direct dilution; PLASMA-MASS SPECTROMETRY; TRACE-ELEMENTS; WHOLE-BLOOD; MULTIELEMENTAL CHARACTERIZATION; HUMAN HAIR; URINE; SAMPLES; NAILS; ZN; CD;
D O I
10.1016/j.ijms.2017.10.001
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A high-throughput, low sample consumption and sensitive method was developed for the simultaneous determination of 21 elements in human serum using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) with collision/reaction cell technique. Instead of the common acid dilution method, weak alkali dilution was used to prepare the samples. As the human blood pH is in the range of 7.35-7.45, weak alkali dilution has less impact on the sample components. Usage of Reaction mode with NH3 was necessary for Al, Cr and Se. Collision with Helium could reduce polyatomic interference effectively for Mg, V, Mn, Fe, Ni, Co, Ga and As. The reliability of the method was tested using serum reference materials (ClinChek (R) Control, Level I and Level II). Results of the serum reference matched well with the certified values. Finally, 83 serum samples from healthy individuals were analyzed in this work, which provided important reference value for diagnosis of diseases caused by elements disorder. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [1] Simultaneous determination of P and S in human serum, blood plasma and whole blood by ICP-MS with collision/reaction cell technology
    Gong, Zi-Shan
    Yang, Ru
    Sun, Chuan-Qiang
    Han, Wen-Nian
    Jiang, Xue-Hui
    Xu, Shu-Xin
    Wang, Yan
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2019, 445
  • [2] A simple, rapid method for simultaneous determination of multiple elements in serum by using an ICP-MS equipped with collision cell
    Zhang, Guofu
    Zhang, Fengquan
    Liu, Wannian
    Liu, Chili
    You, Jing
    Tian, Meichen
    Cao, Tingting
    Jiang, Jing
    Yang, Zhongzhi
    Wu, Hui
    Wu, Weidong
    BMC CHEMISTRY, 2023, 17 (01)
  • [3] The application of collision/reaction cell for detection of impurity elements in rare earth metals by ICP-MS analysis
    Leikin, A. Yu.
    Karandashev, V. K.
    Lisovskii, S. V.
    Volkov, I. A.
    INORGANIC MATERIALS, 2015, 51 (14) : 1389 - 1393
  • [4] Determination of 20 Trace Elements in the Blood Collection Tubes with ICP-MS
    Xiong Chan
    Jiang, Xue-hui
    Tian Ya-ping
    Ma Qing-wei
    Liu Li-peng
    Guo Guang-hong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (11) : 3676 - 3682
  • [5] Collision/Reaction Cell ICP-MS with Shielded Torch and Sector Field ICP-MS for the Simultaneous Determination of Selenium Isotopes in Biological Matrices
    Al-Saad, Khalid A.
    Amr, Mohammed A.
    Helal, Abdulfattah I.
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2011, 140 (01) : 103 - 113
  • [6] A comparison of double-focusing sector field ICP-MS, ICP-OES and octopole collision cell ICP-MS for the high-accuracy determination of calcium in human serum
    Simpson, LA
    Hearn, R
    Merson, S
    Catterick, T
    TALANTA, 2005, 65 (04) : 900 - 906
  • [7] Determination of 21 Inorganic Elements in Urine Samples by ICP-MS Using KED System
    Liu Liu
    Liu Zhe
    Yang Yi-bing
    Wang Qin
    Xu Dong-qun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (04) : 1262 - 1266
  • [8] Determination of toxic and essential trace elements in serum of healthy and hypothyroid respondents by ICP-MS: A chemometric approach for discrimination of hypothyroidism
    Stojsavljevic, Aleksandar
    Trifkovic, Jelena
    Rasic-Milutinovic, Zorica
    Jovanovic, Dragana
    Bogdanovic, Gradimir
    Mutic, Jelena
    Manojlovic, Dragan
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2018, 48 : 134 - 140
  • [9] Direct Determination of Gold in Rock Samples Using Collision Cell Quadrupole ICP-MS
    Yim, Seong A.
    Choi, Man Sik
    Chae, Jung Sun
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (01) : 171 - 178
  • [10] The application of collision/reaction cell for detection of impurity elements in rare earth metals by ICP-MS analysis
    A. Yu. Leikin
    V. K. Karandashev
    S. V. Lisovskii
    I. A. Volkov
    Inorganic Materials, 2015, 51 : 1389 - 1393