A Re-Adjustable Sling for Female Recurrent Stress Incontinence and Sphincteric Deficiency: Outcomes and Complications in 125 Patients Using the Remeex Sling System

被引:27
作者
Errando, Carlos [1 ]
Rodriguez-Escovar, Fernando [1 ]
Gutierrez, Cristina [1 ]
Baez, Carlos [1 ]
Arano, Pedro [1 ]
Villavicencio, Humberto [1 ]
机构
[1] Fundacio Puigvert, Dept Female & Funct Urol, Barcelona, Spain
关键词
intrinsic sphincteric deficiency; stress incontinence; surgical treatment; VAGINAL TAPE PROCEDURE; URINARY-INCONTINENCE;
D O I
10.1002/nau.20879
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Aims: To evaluate the outcomes, complications, and quality of life of patients after a Remeexre-adjustable sling for recurrent stress urinary incontinence (SUI) and intrinsic sphincteric deficiency (ISD) indications. Methods: One hundred twenty-five patients with SUI were prospectively evaluated following a re-adjustable sling in a single tertiary academic Center. Patients were classified by Q-tip, urodynamic and clinical criteria into ISD (70) and recurrent SUI (55). All patients underwent a re-adjustable sling placement. Outcome measures included pad-test, urodynamics, and the King's Health Questionnaire. Results: After a mean follow-up of 38 months (26-72), 109 patients (87%) are cured of SUI based on pad-test, clinical, and urodynamic criteria. Sixteen patients (13%) remain incontinent. Nine of those (7%) are satisfied to the point that they decline re-adjustment of the sling, and seven (6%) are on the waiting list for re-adjustment. Nineteen patients show urge incontinence (9 with previous urodynamic mixed incontinence, 10 (8%) with de novo detrusor overactivity). Twenty-one patients benefited from a readjustment of the sling during the follow-up. The tension was increased in 17 cases (continent at discharge) due to recurrence of SUI, and reduced in 4 due to obstruction. The Varitensor was removed in 1 case due to infection. No other complications were seen. Conclusions: The Remeex re-adjustable sling system provides a good cure rate for recurrent SUI and ISD with a low complication rate. The ability to increase or decrease sling tension allowed us to achieve cure in patients who were not initially dry, and to relieve obstruction in every case attempted. Neurourol. Urodynam. 29:1429-1432, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1429 / 1432
页数:4
相关论文
共 22 条
[1]   Complications of tension-free vaginal tape surgery: a multi-institutional review [J].
Abouassaly, R ;
Steinberg, JR ;
Lemieux, M ;
Marois, C ;
Gilchrist, LI ;
Bourque, JL ;
Tu, LM ;
Corcos, J .
BJU INTERNATIONAL, 2004, 94 (01) :110-113
[2]  
Abrams P, 2002, NEUROUROL URODYNAM, V21, P167, DOI 10.1002/nau.10052
[3]   Results 1 year after the Reemex system was applied for the treatment of stress urinary incontinence caused by intrinsic sphincter deficiency [J].
Araco, F. ;
Gravante, G. ;
Dati, S. ;
Bulzomi', V. ;
Sesti, F. ;
Piccione, E. .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2008, 19 (06) :783-786
[4]  
*AUA, AUA CLIN PRACT GUID
[5]  
Bujons Tur A, 2007, Actas Urol Esp, V31, P43
[6]  
Campos-Fernandes JL, 2006, PROG UROL, V16, P184
[7]  
Chu C.C., 1997, WOUND CLOSURE BIOMAT, P237
[8]   Five-year outcomes of the tension-free vaginal tape procedure for treatment of female stress urinary incontinence [J].
Doo, Chin Kyung ;
Hong, Bumsik ;
Chung, Byung Joo ;
Kim, Ji Yoon ;
Jung, Hee Chang ;
Lee, Kyu-Sung ;
Choo, Myung-Soo .
EUROPEAN UROLOGY, 2006, 50 (02) :333-338
[9]   Surgical treatment of urinary stress incontinence using a method for postoperative adjustment of sling tension (Remeex System) [J].
Iglesias, X ;
Espuña, M .
INTERNATIONAL UROGYNECOLOGY JOURNAL AND PELVIC FLOOR DYSFUNCTION, 2003, 14 (05) :326-329
[10]   The coexistence of intrinsic sphincter deficiency with type II stress incontinence [J].
Kayigil, Ö ;
Ahmed, SI ;
Metin, A .
JOURNAL OF UROLOGY, 1999, 162 (04) :1365-1366