Microbial Fuel Cell as a Bioelectrochemical Sensor of Nitrite Ions

被引:10
作者
Klevinskas, Arnas [1 ]
Kantminiene, Kristina [1 ]
Zmuidzinaviciene, Nerita [1 ]
Jonuskiene, Ilona [2 ]
Griskonis, Egidijus [1 ]
机构
[1] Kaunas Univ Technol, Dept Phys & Inorgan Chem, Fac Chem Technol, Radvilenu Pl 19, LT-50254 Kaunas, Lithuania
[2] Kaunas Univ Technol, Dept Organ Chem, Fac Chem Technol, Radvilenu Pl 19, LT-50254 Kaunas, Lithuania
关键词
microbial fuel cell; biosensor; nitrite; Shewanella putrefaciens; graphite felt; ELECTROCHEMICAL SENSOR; WASTE-WATER; GRAPHENE; TECHNOLOGY; BIOSENSOR;
D O I
10.3390/pr9081330
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The deteriorating environmental quality requires a rapid in situ real-time monitoring of toxic compounds in environment including water and wastewater. One of the most toxic nitrogen-containing ions is nitrite ion, therefore, it is particularly important to ensure that nitrite ions are completely absent in surface and ground waters as well as in wastewater or, at least, their concentration does not exceed permissible levels. However, no selective ion electrode, which would enable continuous measurement of nitrite ion concentration in wastewater by bioelectrochemical sensor, is available. Microbial fuel cell (MFC)-based biosensor offers a sustainable low-cost alternative to the monitoring by periodic sampling for laboratory testing. It has been determined, that at low (0.01-0.1 mg center dot L-1) and moderate (1.0-10 mg center dot L-1) concentration of nitrite ions in anolyte-model wastewater, the voltage drop in MFC linearly depends on the logarithm of nitrite ion concentration of proving the potential of the application of MFC-based biosensor for the quantitative monitoring of nitrite ion concentration in wastewater and other surface water. Higher concentrations (100-1000 mg center dot L-1) of nitrite ions in anolyte-model wastewater could not be accurately quantified due to a significant drop in MFC voltage. In this case MFC can potentially serve as a bioelectrochemical early warning device for extremely high nitrite pollution.
引用
收藏
页数:14
相关论文
共 50 条
[21]   Sensitivity and reusability of a simple microbial fuel cell-based sensor for detecting bisphenol A in wastewater [J].
Zhu, Ting -Jun ;
Lin, Chi-Wen ;
Liu, Shu-Hui .
CHEMOSPHERE, 2023, 320
[22]   A novel bioelectrochemical BOD sensor operating with voltage input [J].
Modin, Oskar ;
Wilen, Britt-Marie .
WATER RESEARCH, 2012, 46 (18) :6113-6120
[23]   Performance of a microbial fuel cell-based biosensor for online monitoring in an integrated system combining microbial fuel cell and upflow anaerobic sludge bed reactor [J].
Jia, Hui ;
Yang, Guang ;
Wang, Jie ;
Ngo, Huu Hao ;
Guo, Wenshan ;
Zhang, Hongwei ;
Zhang, Xinbo .
BIORESOURCE TECHNOLOGY, 2016, 218 :286-293
[24]   Microbial Fuel Cell [J].
Jha, S. ;
Sharma, P. ;
Prakash, A. .
RESEARCH JOURNAL OF BIOTECHNOLOGY, 2023, 18 (05) :122-133
[25]   Microbial Fuel Cell-Based Toxicity Sensor [J].
Rozene, Juste ;
Zinovicius, Antanas ;
Kacinskaite, Barbora ;
Bucinskas, Vytautas ;
Ramanavicius, Arunas ;
Morkvenaite-Vilkonciene, Inga .
AUTOMATION 2020: TOWARDS INDUSTRY OF THE FUTURE, 2020, 1140 :379-388
[26]   Novel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell [J].
Kim, BH ;
Chang, IS ;
Gil, GC ;
Park, HS ;
Kim, HJ .
BIOTECHNOLOGY LETTERS, 2003, 25 (07) :541-545
[27]   Novel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell [J].
Byung Hong Kim ;
In Seop Chang ;
Geun Cheol Gil ;
Hyung Soo Park ;
Hyung Joo Kim .
Biotechnology Letters, 2003, 25 :541-545
[28]   Applicability of a submersible microbial fuel cell for Cr(VI) detection in water [J].
Chung, Hyeonyong ;
Ju, Won Jung ;
Jho, Eun Hea ;
Nam, Kyoungphile .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2016, 188 (11)
[29]   Essential Data and Techniques for Conducting Microbial Fuel Cell and other Types of Bioelectrochemical System Experiments [J].
Logan, Bruce E. .
CHEMSUSCHEM, 2012, 5 (06) :988-994
[30]   Bioelectrochemical analysis of a hyperthermophilic microbial fuel cell generating electricity at temperatures above 80°C [J].
Fu, Qian ;
Fukushima, Naoya ;
Maeda, Haruo ;
Sato, Kozo ;
Kobayashi, Hajime .
BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2015, 79 (07) :1200-1206