Outbreak of Burkholderia cepacia complex infections associated with contaminated octenidine mouthwash solution, Germany, August to September 2018

被引:30
作者
Becker, Soeren L. [1 ]
Berger, Fabian K. [1 ]
Feldner, Susanne K. [2 ]
Karliova, Irem [2 ]
Haber, Manfred [3 ]
Mellmann, Alexander [4 ]
Schaefers, Hans-Joachim [2 ]
Gaertner, Barbara [1 ]
机构
[1] Saarland Univ, Inst Med Microbiol & Hyg, Homburg, Germany
[2] Saarland Univ, Dept Thorac & Cardiovasc Surg, Homburg, Germany
[3] Saarland Univ, Hosp Pharm, Homburg, Germany
[4] Univ Hosp Munster, Inst Hyg, Munster, Germany
关键词
LIQUID DOCUSATE;
D O I
10.2807/1560-7917.ES.2018.23.42.1800540
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Three German patients developed nosocomial pneumonia after cardiac surgery and had Burkholderia cepacia complex detected in respiratory specimens. Two patients died of septic multi-organ failure. Wholegenome sequencing detected genetically identical B. cepacia complex strains in patient samples, from a batch of octenidine mouthwash solution, which had been used for nursing care, as well as in samples obtained from the manufacturer during production. Contamination of medical products during manufacturing may lead to international outbreaks.
引用
收藏
页码:5 / 8
页数:4
相关论文
共 16 条
[11]   Burkholderia cepacia complex infections: More complex than the bacterium name suggest [J].
Sfeir, Maroun M. .
JOURNAL OF INFECTION, 2018, 77 (03) :166-170
[12]   An unusual source of Burkholderia cepacia outbreak in a neonatal intensive care unit [J].
Shrivastava, B. ;
Sriram, A. ;
Shetty, S. ;
Doshi, R. ;
Varior, R. .
JOURNAL OF HOSPITAL INFECTION, 2016, 94 (04) :358-360
[13]   Outbreak of Burkholderia cepacia complex bacteremia in a chemotherapy day care unit due to intrinsic contamination of an antiemetic drug [J].
Singhal, T. ;
Shah, S. ;
Naik, R. .
INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 33 (01) :117-119
[14]  
Sommerstein Rami, 2017, Euro Surveill, V22, DOI 10.2807/1560-7917.ES.2017.22.49.17-00213
[15]   Outbreak of Burkholderia cepacia pseudobacteraemia caused by intrinsically contaminated commercial 0.5% chlorhexidine solution in neonatal intensive care units [J].
Song, J. E. ;
Kwak, Y. G. ;
Um, T. H. ;
Cho, C. R. ;
Kim, S. ;
Park, I. S. ;
Hwang, J. H. ;
Kim, N. ;
Oh, G-B. .
JOURNAL OF HOSPITAL INFECTION, 2018, 98 (03) :295-299
[16]   Multi-institutional outbreak of Burkholderia cepacia complex associated with contaminated mannitol solution prepared in compounding pharmacy [J].
Souza Dias, Maria Beatriz ;
Cavassin, Larissa G. T. ;
Stempliuk, Valeska ;
Xavier, Luciene S. ;
Lobo, Renata D. ;
Sampaio, Jorge L. M. ;
Pignatari, Antonio Carlos ;
Borrasca, Vera L. ;
Bierrenbach, Ana Luiza ;
Toscano, Cristiana M. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (11) :1038-1042