The present work proposes the use of Bacillus subtilis immobilized on Amberlite XAD-4 as new biosorbent in trace metal determination. The procedure is based on the biosorption of Cu and Cd ions on a column of Amberlite XAD-4 resin loaded with dried, dead bacterial components prior to their determination by flame AAS. Various parameters such as pH, amount of adsorbent, eluent type and volume, flow rate of solution and matrix interference effect on the retention of the metal ions have been studied. The optimum pH values of quantitative sorption for Cu and Cd were found to be 7.0 and 7.5, respectively. These metal ions can be desorbed with 1 M HCl (recovery, 96-100%). The,sorption capacity of the resin was 0.0297 and 0.035 mmol g(-1) for Cu(2+) and Cd(2+), respectively. The tolerance limit of some electrolytes were also studied. This procedure was applied to Cu(2+) and Cd(2+) determination in aqueous solutions, including river and well water systems. In order to evaluate the accuracy of the proposed procedure, the certified reference materials, NRCC-SLRS-4 Riverine water and LGC7162 Strawberry leaves were analyzed. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:166 / 173
页数:8
相关论文
共 29 条
[1]   Determination of Cu, Zn, Fe, Ni and Cd by flame atomic absorption spectrophotometry after preconcentration by Escherichia coli immobilized on sepiolite [J].
Bag, H ;
Türker, AR ;
Lale, M .
TALANTA, 2000, 51 (05) :1035-1043
[2]   Determination of iron and nickel by flame atomic absorption spectrophotometry after preconcentration on Saccharomyces cerevisiae immobilized sepiolite [J].
Bag, H ;
Lale, M ;
Turker, AR .
TALANTA, 1998, 47 (03) :689-696
[3]   The use of Agrobacterium tumefacients immobilized on Amberlite XAD-4 as a new biosorbent for the column preconcentration of iron(III), cobalt(II), manganese(II) and chromium(III) [J].
Baytak, S ;
Türker, AR .
TALANTA, 2005, 65 (04) :938-945
[4]   Use of Amberlite XAD-2 loaded with 1-(2-pyridylazo)-2-naphthol as a preconcentration system for river water prior to determination of Cu2+, Cd2+ and Pb2+ by flame atomic absorption spectroscopy [J].
Bermejo-Barrera, P ;
Nancy, MA ;
Cristina, DL ;
Adela, BB .
MICROCHIMICA ACTA, 2003, 142 (1-2) :101-108
[5]   Adsorption of cadmium to Bacillus subtilis bacterial cell walls:: A pH-dependent X-ray absorption fine structure spectroscopy study [J].
Boyanov, MI ;
Kelly, SD ;
Kemner, KM ;
Bunker, BA ;
Fein, JB ;
Fowle, DA .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2003, 67 (18) :3299-3311
[6]   Bioaccumulation of copper, zinc, cadmium and lead by Bacillus sp., Bacillus cereus, Bacillus sphaericus and Bacillus subtilis [J].
da Costa, ACA ;
Duta, FP .
BRAZILIAN JOURNAL OF MICROBIOLOGY, 2001, 32 (01) :1-5
[7]   Hydrogels for immobilization of bacteria used in the treatment of metal-contaminated wastes [J].
Degiorgi, CF ;
Pizarro, RA ;
Smolko, EE ;
Lora, S ;
Carenza, M .
RADIATION PHYSICS AND CHEMISTRY, 2002, 63 (01) :109-113
[8]   Determination of Cd in biological samples by flame AAS following on-line preconcentration by complexation with 0,0-diethyldithiophosphate and solid phase extraction with Amberlite XAD-4 [J].
dos Santos, EJ ;
Herrmann, AB ;
Ribeiro, AS ;
Curtius, AJ .
TALANTA, 2005, 65 (02) :593-597
[9]   Polymer supported humic acid for separation and preconcentration of thorium(IV) [J].
Erdogan, S ;
Merdivan, M ;
Hamamci, C ;
Akba, O ;
Baysal, A .
ANALYTICAL LETTERS, 2004, 37 (12) :2565-2575
[10]   Microorganisms in inorganic chemical analysis [J].
Godlewska-Zylkiewicz, B .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (01) :114-123