Accuracy of portable devices in measuring peak cough flow

被引:25
作者
Kulnik, Stefan Tino [1 ]
MacBean, Victoria [2 ]
Birring, Surinder Singh [2 ]
Moxham, John [2 ]
Rafferty, Gerrard Francis [2 ]
Kalra, Lalit [1 ]
机构
[1] Kings Coll London, Inst Psychiat Psychol & Neurosci, Dept Clin Neurosci, Stroke Res Team, London SE5 8AF, England
[2] Kings Coll Hosp London, Kings Coll London, Div Asthma Allergy & Lung Biol, Sch Med,Dept Resp Med & Allergy,Chest Unit, London SE5 9RS, England
基金
美国国家卫生研究院;
关键词
peak cough flow; accuracy; peak flow meter; spirometer; pneumotachograph; EXPIRATORY FLOW; MUSCLE STRENGTH; VOLUME; PREDICTORS; EFFICIENCY; MANEUVERS; CAPACITY;
D O I
10.1088/0967-3334/36/2/243
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Peak cough flow (PCF) measurements can be used as indicators of cough effectiveness. Portable peak flow meters and spirometers have been used to measure PCF, but little is known about their accuracy compared to pneumotachograph systems. The aim of this study was to compare the accuracy of four portable devices (Mini-Wright and Assess peak flow meters, SpiroUSB and Microlab spirometers) in measuring PCF with a calibrated laboratory based pneumotachograph system. Twenty healthy volunteers (mean (SD) age 45 (16) years) coughed through a pneumotachograph connected in series with each portable device in turn, and the differences in PCF readings were analysed. In addition, mechanically generated flow waves of constant peak flow were delivered through each device both independently and when connected in series with the pneumotachograph. Agreement between PCF readings obtained with the pneumotachograph and the portable devices was poor. Peak flow readings were on average lower by approximately 50 L min(-1) when measured using the portable devices; 95% limits of agreement spanned approximately 150 L min(-1). The findings highlight the potential for inaccuracy when using portable devices for the measurement of PCF. Depending on the measurement instrument used, absolute values of PCF reported in the literature may not be directly comparable.
引用
收藏
页码:243 / 257
页数:15
相关论文
共 36 条
[1]   Prevention of pulmonary morbidity for patients with Duchenne muscular dystrophy [J].
Bach, JR ;
Ishikawa, Y ;
Kim, H .
CHEST, 1997, 112 (04) :1024-1028
[2]   Expiratory flow maneuvers in patients with neuromuscular diseases [J].
Bach, JR ;
Gonçalves, MR ;
Páez, S ;
Winck, JC ;
Leitao, S ;
Abreu, P .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2006, 85 (02) :105-111
[3]   AMYOTROPHIC-LATERAL-SCLEROSIS - PREDICTORS FOR PROLONGATION OF LIFE BY NONINVASIVE RESPIRATORY AIDS [J].
BACH, JR .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1995, 76 (09) :828-832
[4]   Criteria for extubation and tracheostomy tube removal for patients with ventilatory failure - A different approach to weaning [J].
Bach, JR ;
Saporito, LR .
CHEST, 1996, 110 (06) :1566-1571
[5]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[6]   Guidelines for the physiotherapy management of the adult, medical, spontaneously breathing patient [J].
Bott, J. ;
Blumenthal, S. ;
Buxton, M. ;
Ellum, S. ;
Falconer, C. ;
Garrod, R. ;
Harvey, A. ;
Hughes, T. ;
Lincoln, M. ;
Mikelsons, C. ;
Potter, C. ;
Pryor, J. ;
Rimington, L. ;
Sinfield, F. ;
Thompson, C. ;
Vaughn, P. ;
White, J. .
THORAX, 2009, 64 :1-51
[7]   Air stacking and chest compression increase peak cough flow in patients with Duchenne muscular dystrophy [J].
Brito, Magneide Fernandes ;
Moreira, Gustavo Antonio ;
Pradella-Hallinan, Marcia ;
Tufik, Sergio .
JORNAL BRASILEIRO DE PNEUMOLOGIA, 2009, 35 (10) :973-979
[8]  
Cardoso Fernanda Ef, 2012, Int Arch Med, V5, P25, DOI 10.1186/1755-7682-5-25
[9]   The effects of lung volume recruitment on coughing and pulmonary function in patients with ALS [J].
Cleary, Stuart ;
Misiaszek, John E. ;
Kalra, Sanjay ;
Wheeler, Sonya ;
Johnston, Wendy .
AMYOTROPHIC LATERAL SCLEROSIS AND FRONTOTEMPORAL DEGENERATION, 2013, 14 (02) :111-115
[10]   Effect of long-term steroids on cough efficiency and respiratory muscle strength in patients with Duchenne muscular dystrophy [J].
Daftary, Ameet S. ;
Crisanti, Mark ;
Kalra, Maninder ;
Wong, Brenda ;
Amin, Raouf .
PEDIATRICS, 2007, 119 (02) :E320-E324