A prestress testing method for the steel strands inside in-service structures based on the electrical resistance

被引:14
|
作者
Zhang, Senhua [1 ,2 ]
Zhou, Jianting [1 ,2 ]
Tan, Kui [1 ,2 ]
Zhang, Hong [1 ,2 ]
Qian, Ji [1 ,2 ]
Liu, Huiling [1 ,2 ]
Liao, Leng [1 ,3 ]
机构
[1] Chongqing Jiaotong Univ, State Key Lab Mt Bridge & Tunnel Engn, Chongqing 400074, Peoples R China
[2] Chongqing Jiaotong Univ, Sch Civil Engn, Chongqing 400074, Peoples R China
[3] Chongqing Jiaotong Univ, Sch Mat Sci & Engn, Chongqing 400074, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrical resistance; In-service structure; Internal steel strand; Prestress; Non-destructive testing;
D O I
10.1016/j.measurement.2021.109930
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To test the prestress of internal prestress steel strands, the relationship between the resistance and the prestress was analyzed. The equivalent electrical models of the testing systems were established. The results of the prestress testing experiments showed that there was a nearly linear relationship between the resistance and the prestress. Steel strands with similar physical properties had similar resistance-stress relationships that were not influenced by the prestress variation. Connecting both ends of the steel strand to the testing circuit, the prestress of the inside steel strands could be measured outside the structures. Both in the structural construction phase and the operation phase, the prestress testing errors were about 10%. When testing long steel strands, the proposed method may have higher sensitivity and smaller errors.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] SMALL PUNCH TESTING FOR DETERMINING THE MATERIAL TOUGHNESS OF LOW-ALLOY STEEL-COMPONENTS IN-SERVICE
    FOULDS, J
    VISWANATHAN, R
    JOURNAL OF ENGINEERING MATERIALS AND TECHNOLOGY-TRANSACTIONS OF THE ASME, 1994, 116 (04): : 457 - 464
  • [42] Offshore In-Service Resistance of Double Joints Under Strain-Based Conditions
    Melis, Giorgio
    Fonzo, Andrea
    Ferino, Jan
    Quintanilla, Hector
    Marines-Garcia, Israel
    Darcis, Philippe
    Marchesani, Furio
    Vitali, Luigino
    INTERNATIONAL JOURNAL OF OFFSHORE AND POLAR ENGINEERING, 2015, 25 (04) : 255 - 262
  • [43] Reliability-Based Load and Resistance Factor Rating Using In-Service Data
    Bhattacharya, Baidurya
    Li, Degang
    Chajes, Michael
    Hastings, Jason
    JOURNAL OF BRIDGE ENGINEERING, 2005, 10 (05) : 530 - 543
  • [44] A deflection-based practicable method for health monitoring of in-service bridges
    Prakash, G.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (07)
  • [45] Study on Multi-Crack Damage Evolution and Fatigue Life of Corroded Steel Wires Inside In-Service Bridge Suspenders
    Deng, Luming
    Deng, Yulin
    APPLIED SCIENCES-BASEL, 2024, 14 (20):
  • [46] Study on Multi-Crack Damage Evolution and Fatigue Life of Corroded Steel Wires Inside In-Service Bridge Suspenders
    Deng, Luming
    Deng, Yulin
    SSRN,
  • [47] Electrical Resistance Method for Fatigue Crack Detection of Steel Deck
    Yuan Zhouzhiyuan
    Ji Bohai
    Fu Zhongqiu
    Liu Rong
    Cheng Miao
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 1397 - 1401
  • [48] TESTING METHOD FOR IN-SERVICE LINE OF OPTICAL SUBSCRIBER LOOPS WITH OPTICAL-TIME DOMAIN REFLECTOMETER
    TAKASUGI, H
    SUZUKI, H
    TOMITA, N
    CHIDA, R
    OGUCHI, T
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART I-COMMUNICATIONS, 1994, 77 (03): : 41 - 54
  • [50] TENSOMETRIC METHOD FOR TESTING CORROSION CRACKING RESISTANCE OF REINFORCING STEEL
    KHAIT, IG
    RENSKII, AB
    INDUSTRIAL LABORATORY, 1970, 36 (12): : 1915 - &