Integrated Compression Screw Stabilization of the Dorsal Lunate Facet in Intra-Articular Distal Radius Fractures

被引:8
|
作者
Ruch, David S. [1 ]
Tocci, Francesca L. [1 ]
Grier, A. Jordan [1 ]
Miles, Jeremy J. [1 ]
Patel, Preet S. [3 ]
Mithani, Suhail K. [2 ]
Richard, Marc J. [1 ]
机构
[1] Duke Univ, Dept Orthopaed Surg, Div Hand Surg, Med Ctr, 2301 Erwin Rd, Durham, NC 27710 USA
[2] Duke Univ, Sch Med, Dept Orthopaed & Plast Surg, Med Ctr, Durham, NC 27710 USA
[3] Duke Univ, Sch Med, Durham, NC 27710 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2020年 / 45卷 / 04期
关键词
Distal radius; lunate facet; distal radius fixation; VOLAR PLATE FIXATION; LOCKING PLATES; OPEN REDUCTION; INTERNAL-FIXATION; COMPLICATIONS; FRAGMENT; MANAGEMENT; SYSTEM;
D O I
10.1016/j.jhsa.2019.09.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To evaluate outcomes of intra-articular distal radius fractures with displaced dorsal lunate facet fragments treated with a combination of volar plating and the use of a dorsal screw that integrates into the plate. Methods We reviewed a retrospective cohort of 22 patients who underwent open reduction and internal fixation of an intra-articular distal radius fracture with a volar plate in conjunction with the Frag-Loc Compression screw. Patient charts and radiographs were reviewed for clinical and radiographic outcomes. Results A total of 12 patients with a minimum 6-month follow-up who met all eligibility criteria were included in this study. There were 8 women and 4 men. The mean age was 55.2 years. Mean follow-up was 11.5 months (range, 6-21 months). The most common mechanism of injury was a fall from standing (75.0%). At final follow-up, all patients were able to return to their previous level of function. Bony union was achieved in all patients at the time of final follow-up. Average radiographic parameters at final follow-up were radial inclination 24.2 degrees +/- 5.3 degrees, volar tilt 1.3 degrees +/- 5.2 degrees, and ulnar variance 0.9 +/- 1.7 mm During the follow-up period, transient median nerve paresthesias were observed in 4 patients, with spontaneous resolution in 3 of 4 patients. Loss of articular reduction was not observed in any case. Conclusions This study demonstrates satisfactory clinical and radiographic results and minimal complications with utilization of a new fixation device for distal radius fractures with displaced dorsal lunate facet fragments. Copyright (C) 2020 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:361.e1 / 361.e7
页数:7
相关论文
共 50 条
  • [1] Dorsal wrist plating for the management of intra-articular distal radius fractures
    Brauns, J.
    Vandesande, W.
    ACTA ORTHOPAEDICA BELGICA, 2024, 90 (01): : 110 - 114
  • [2] Treatment of Intra-articular Distal Radius Fractures
    Omokawa, Shohei
    Abe, Yukio
    Imatani, Junya
    Moritomo, Hisao
    Suzuki, Daisuke
    Onishi, Tadanobu
    HAND CLINICS, 2017, 33 (03) : 529 - +
  • [3] Arthroscopically Assisted Osteosynthesis of Distal Radius Intra-articular Fractures
    Ozden, Erdem
    Gurbuz, Hakan
    Ozturk, Kahraman
    Pehlivan, Ali Tufan
    Dedeoglu, Suleyman Semih
    JOURNAL OF ACADEMIC RESEARCH IN MEDICINE-JAREM, 2019, 9 (02): : 71 - 79
  • [4] Origins of the threshold for surgical intervention in intra-articular distal radius fractures
    Esworthy, G. P.
    Johnson, N. A.
    Divall, P.
    Dias, J. J.
    BONE & JOINT JOURNAL, 2021, 103B (09): : 1457 - 1461
  • [5] Arthroscopic Management of Intra-articular Malunion in Fractures of the Distal Radius
    del Pinal, Francisco
    Clune, James
    HAND CLINICS, 2017, 33 (04) : 669 - +
  • [6] Treatment of Intra-Articular Distal Radius Fractures using Fragment-Specific Fixation
    Khalil, Mohammed Raafat
    Abdelsalam, Abdelsalam Eid
    Elzohairy, Mohamed Mansour
    rGaber, Ahmed Mashhou
    INTERNATIONAL JOURNAL OF EARLY CHILDHOOD SPECIAL EDUCATION, 2022, 14 (03) : 5840 - 5848
  • [7] Dorsal approach and internal fixation of impacted intra-articular distal radius fractures with 2.4 mm locking plates
    De Smet, A.
    Lamouille, J.
    Vostrel, P.
    Loret, M.
    Hoffmeyer, P.
    Beaulieu, J. -Y.
    HAND SURGERY & REHABILITATION, 2016, 35 (03): : 203 - 209
  • [8] Managing the Intra-articular Distal Radius Malunion
    Boe, Chelsea C.
    Kennedy, Stephen A.
    HAND CLINICS, 2024, 40 (01) : 79 - 87
  • [9] Experience with the AO Π-plate for displaced intra-articular fractures of the distal radius
    Krukhaug, Y
    Hove, LM
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2004, 38 (05): : 293 - 296
  • [10] Effect of Screw Length in Volar Plating for Intra-Articular Distal Radius Fractures: A Biomechanical Study
    Hong, Thomas S.
    Lee, Daniel J.
    Jahani, Babak
    Broz, Kaitlyn S.
    Aboytes, Donald A.
    Tang, Simon
    Demartini, Stephen
    Brogan, David M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (12): : 1186 - 1195