Axial or coronal CT scan; which is more accurate in detection of open globe injury?

被引:3
作者
Arabi, Amir [1 ]
Shahraki, Toktam [1 ]
Nezam-slami, Rezvan [1 ]
Esfandiari, Hamed [2 ]
Tavakoli, Mehdi [3 ]
Nikkhah, Homayoun [1 ]
机构
[1] Shahid Beheshti Univ Med Sci, Ophthalm Res Ctr, 23 Paidarfdard St Boostan 9 St,Pasadaran Ave, Tehran 16666, Iran
[2] Olmsted Med Ctr, Dept Ophthalmol, Rochester, MN USA
[3] Univ Alabama Birmingham, Dept Ophthalmol & Visual Sci, Birmingham, AL USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2021年 / 52卷 / 09期
关键词
Open globe injury; Orbital trauma; CT scan; Axial CT; Coronal CT; Computerized tomography; Accuracy; COMPUTED-TOMOGRAPHY; DIAGNOSIS;
D O I
10.1016/j.injury.2021.04.034
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: To evaluate and compare the accuracy of axial versus coronal computerized tomography (CT) scan in detection of open globe injury. Method: In this retrospective study, records of 61 patients with open and 72 patients with closed globe injury were reviewed. One experienced ophthalmologist and one neuroradiologist read the orbital CT scans and accuracy of the axial and coronal planes in detecting open globe injuries were compared. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated and compared for axial and coronal planes. Result: The most common CT finding reported by the readers through the interpretation chart was scleral irregularity (70%), followed by dislocation of the crystalline lens (54%) and vitreous hemorrhage (51%). The sensitivity of axial, coronal and combined CT planes were 74%, 65%, and 79%, respectively. There was no significant difference between axial and coronal CT scans for detecting open globe injuries (P value = 0.075), independent of the type and the location of the globe injury. For posterior injuries and sharp trauma, the sensitivity of coronal plane in detecting open globe injury was significantly lower, compared to axial and combined readings (P value = 0.012 and 0.015, respectively). There was a near perfect agreement between readers for all CT scan readings with a Kappa value of 0.9. Conclusion: Axial CT reading may be as adequate as a multiplanar reading in detection of open globe injury in emergency setting, where timely diagnosis matters. Without clinical and surgical findings, CT cannot provide adequate accuracy for detecting open globe injuries. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2611 / 2615
页数:5
相关论文
共 10 条
  • [1] Computed tomography in the diagnosis of occult open-globe injuries
    Arey, Mark L.
    Mootha, V. Vinod
    Whittemore, Anthony R.
    Chason, David P.
    Blomquist, Preston H.
    [J]. OPHTHALMOLOGY, 2007, 114 (08) : 1448 - 1452
  • [2] CT DIAGNOSIS OF SCLERAL RUPTURE
    BENJAMIN, L
    WORMALD, R
    [J]. EYE-TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1987, 1 : 757 - 761
  • [3] Accuracy of Computed Tomography Imaging Criteria in the Diagnosis of Adult Open Globe Injuries by Neuroradiology and Ophthalmology
    Crowell, Eric L.
    Koduri, Vivek A.
    Supsupin, Emilio P.
    Klinglesmith, Robert E.
    Chuang, Alice Z.
    Kim, Gene
    Baker, Laura A.
    Feldman, Robert M.
    Blieden, Lauren S.
    [J]. ACADEMIC EMERGENCY MEDICINE, 2017, 24 (09) : 1072 - 1079
  • [4] Multidetector CT (MD-CT) in the Diagnosis of Uncertain Open Globe Injuries
    Hoffstetter, P.
    Schreyer, A. G.
    Schreyer, C. I.
    Jung, E. M.
    Heiss, P.
    Zorger, N.
    Framme, C.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (02): : 151 - 154
  • [5] Computed tomography in the diagnosis and prognosis of open-globe injuries
    Joseph, DP
    Pieramici, DJ
    Beauchamp, NJ
    [J]. OPHTHALMOLOGY, 2000, 107 (10) : 1899 - 1906
  • [6] Imaging in orbital trauma
    Lin, Ken Y.
    Ngai, Philip
    Echegoyen, Julio C.
    Tao, Jeremiah P.
    [J]. SAUDI JOURNAL OF OPHTHALMOLOGY, 2012, 26 (04) : 427 - 432
  • [7] Interrater reliability: the kappa statistic
    McHugh, Mary L.
    [J]. BIOCHEMIA MEDICA, 2012, 22 (03) : 276 - 282
  • [8] A system for classifying mechanical injuries of the eye (globe)
    Pieramici, DJ
    Sternberg, P
    Aaberg, TM
    Bridges, WZ
    Capone, A
    Cardillo, JA
    deJuan, E
    Kuhn, F
    Meredith, TA
    Mieler, WF
    Olsen, TW
    Rubsamen, P
    Stout, T
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (06) : 820 - 831
  • [9] VALUE OF COMPUTED-TOMOGRAPHY FOR THE DIAGNOSIS OF A RUPTURED EYE
    SEVEL, D
    KRAUSZ, H
    PONDER, T
    CENTENO, R
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (05) : 870 - 875
  • [10] CT of Globe Rupture: Analysis and Frequency of Findings
    Yuan, Wei-Hsin
    Hsu, Hui-Chen
    Cheng, Hui-Cheng
    Guo, Wan-Yuo
    Teng, Michael Mu-Huo
    Chen, Shih-Jen
    Lin, Tai-Chi
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (05) : 1100 - 1107