Comparison of the Functional Optical Zone in Eyes With High Myopia With High Astigmatism After SMILE and FS-LASIK

被引:7
|
作者
Liu, Shengtao [1 ,2 ,3 ]
Zhang, Xiaoxue
Niu, Lingling [1 ,2 ,3 ]
Yu, Zhiqiang [1 ,2 ,3 ]
Zhou, Xingtao [1 ,2 ,3 ,4 ]
Zhao, Jing [1 ,2 ,3 ,5 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol & Optometry, Shanghai, Peoples R China
[2] Fudan Univ, Chinese Acad Med Sci, NHC Key Lab Myopia, Key Lab Myopia, Shanghai, Peoples R China
[3] Shanghai Res Ctr Ophthalmol & Optometry, Shanghai, Peoples R China
[4] Nanchang Univ, Affiliated Hosp 2, Nanchang, Peoples R China
[5] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol & Optometry, 19 Baoqing Rd, Shanghai 200031, Peoples R China
关键词
INCISION LENTICULE EXTRACTION; LASER-ASSISTED LASIK; HIGHER-ORDER ABERRATIONS; IN-SITU KERATOMILEUSIS; DECENTRATION;
D O I
10.3928/1081597X-20220725-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the functional optical zone (FOZ) in eyes with high myopia with high astigmatism after small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK).METHODS: In total, 45 eyes of 45 patients with high myopia with astigmatism greater than 2.00 diopters (D) who under-went SMILE or FS-LASIK were enrolled. The FOZ, optical zone decentration, and corneal aberrations were analyzed using Scheimpflug imaging. These values were then compared be-tween the two groups 6 months postoperatively.RESULTS: No postoperative complications were observed during follow-up. The mean FOZ diameter was 5.03 +/- 0.31 mm for the FS-LASIK group and 5.24 +/- 0.27 mm for the SMILE group (P = .007), corresponding to reductions of 1.18 +/- 0.23 and 1.01 +/- 0.21 mm, respectively, compared with the programmed optical zone (POZ) (P = .013). A significant dif-ference was noted in the FOZ on the short axis between the two groups (P = .002), whereas no significant difference was observed on the long axis (P = .088). The FOZ area in the FS-LASIK and SMILE groups was 65.39 +/- 6.14% and 70.09 +/- 5.46% of the POZ area, respectively (P = .010). There was no significant difference in decentration between the two groups (0.29 +/- 0.13 mm for the FS-LASIK group vs 0.30 +/- 0.13 mm for the SMILE group, P = .798). A significant increase in spherical aberration was observed in the FS-LASIK group (P < .001). However, the induction of vertical coma was higher in the SMILE group than in the FS-LASIK group (P = .002).CONCLUSIONS: Eyes with high myopia with high astigmatism following SMILE achieved a larger FOZ and less spherical ab-erration but a larger vertical coma introduction than follow-ing FS-LASIK.
引用
收藏
页码:595 / +
页数:8
相关论文
共 50 条
  • [31] Comparison of Refractive Outcomes and Optical Zone Decentration After SMILE Between Patients With Symmetrical and Asymmetrical High Astigmatism
    Yu, Na
    Hou, Xiangtao
    Luo, Yiqi
    Chen, Xi
    Zhuang, Jing
    Yu, Keming
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (04) : 273 - +
  • [32] Comparison of myopic astigmatic correction after cross-assisted SMILE, FS-LASIK, and transPRK
    Yang, Yi-Zeng
    Li, Fen-Fen
    Wu, Shuang-Qing
    Dai, Qi
    Bao, Fang-Jun
    Cheng, Dan
    Zhu, Jun
    Ye, Yu-Feng
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (12) : 1242 - 1248
  • [33] Evaluating the Effectiveness and Corneal Aberrations After FS-LASIK and SMART (SPT-Guided TransPRK) Surgery for Myopia and Astigmatism: Retrospective Study
    Xue, Yanzhen
    Guo, Yonghong
    Zhang, Jun
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (02) : e164 - e172
  • [34] Five-year results of small incision lenticule extraction (SMILE) and femtosecond laser LASIK (FS-LASIK) for myopia
    Li, Meiyan
    Li, Meng
    Chen, Yingjun
    Miao, Huamao
    Yang, Dong
    Ni, Katherine
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2019, 97 (03) : E373 - E380
  • [35] Comparison of visual quality after Q value-guided FS-LASIK and SMILE for correction of myopia with age-related accommodation deficiency
    Zhang, Ruiyu
    Yuan, Yifei
    Zhang, Yu
    Chen, Yueguo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025, 263 (02) : 571 - 580
  • [36] Intraocular Pressure Changes and Relationship With Corneal Biomechanics After SMILE and FS-LASIK
    Li, Hua
    Wang, Yan
    Dou, Rui
    Wei, Pinghui
    Zhang, Jiamei
    Zhao, Wei
    Li, Liuyang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (10) : 4180 - 4186
  • [37] Comparison of choroidal thickness in high myopic eyes after FS-LASIK versus implantable collamer lens implantation with swept-source optical coherence tomography
    Zhang, Jing
    He, Fang-Lin
    Liu, Yan
    Fan, Xian-Qun
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (05) : 773 - 781
  • [38] Changes of Functional Optical Zone After LASIK for Hyperopia and Hyperopic Astigmatism
    Roesler, Christian
    Kohnen, Thomas
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (07) : 476 - 481
  • [39] Changes in asphericity of anterior and posterior corneal surfaces for mild-moderate and high myopia after topography-guided FS-LASIK
    Wu, Yuan
    Sun, Shengshu
    Liu, Zhanglin
    Wang, Shuhan
    Wang, Guiqin
    Zhao, Shaozhen
    Wei, Ruihua
    Huang, Yue
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (11) : 3555 - 3565
  • [40] FS-LASIK for the treatment of moderate-to-high hyperopia
    Alio del Barrio, Jorge L.
    Milan-Castillo, Roberto
    Canto-Cerdan, Mario
    Molina-Lespron, Aleyda
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (06) : 558 - 564