Spherical aberration and depth of focus in eyes implanted with aspheric and spherical intraocular lenses -: A prospective randomized study

被引:105
作者
Rocha, Karolinne Maia [1 ]
Soriano, Eduardo S. [1 ]
Chamon, Wallace [1 ]
Chalita, Maria Regina [1 ]
Nose, Walton [1 ]
机构
[1] Univ Fed Sao Paulo, Paulista Sch Med, Dept Ophthalmol, Sao Paulo, Brazil
关键词
D O I
10.1016/j.ophtha.2007.01.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Y Purpose: To compare distance-corrected, near, and intermediate visual acuities as a measurement of depth of focus and spherical aberration of eyes implanted with aspheric and spherical intraocular lenses (IOLs). Design: Randomized prospective study. Participants: One hundred twenty eyes of 60 patients with bilateral cataract implanted with 3 IOL models (AcrySof IQ, AcrySof SN60AT [Alcon Laboratories, Fort Worth, TX], and Sensar AR40 [Allergan Surgical, Irvine, CA]). Methods: Pupil diameter was analyzed by using a Colvard pupillometer (OASIS Medical, Inc., Glendora, CA) under photopic, mesopic, and scotopic conditions. Distance (6 m), intermediate (1 m), and near (0.33 m) visual acuities were measured with distance correction in place 90 days after surgery. Wavefront analysis (LadarWave; Alcon Laboratories) was performed using 5-mm and measured photopic pupil diameter at 30 and 90 days after surgery. Main Outcome Measures: To evaluate spherical aberration and depth of focus (by means of distance-corrected near and intermediate visual acuity) in patients implanted with aspheric and spherical IOLs. Results: Photopic pupil sizes in each group were similar at 30 days after surgery. At 90 days after surgery, mean logarithm of the minimum angle of resolution distance-corrected near visual acuity (-standard deviation [SDI) was 0.50 +/- 0.20 in the AcrySof IQ group, 0.38 +/- 0.1 7 in the AcrySof SN60AT group, and 0.45 +/- 0.16 in Sensar AR40 group. Mean spherical aberration values (+/- SD) were 0.03 +/- 0.05 mu m in the AcrySof IQ group, 0.24 +/- 0.04 mu m in the AcrySof SN60AT group, and 0.14 +/- 0.07 mu m in the Sensar AR40 group. The AcrySof IQ group showed a statistically significant lower induction of spherical aberration and worse distance-corrected near visual acuity. The AcrySof SN60AT group showed statistically significant higher mean spherical aberration values and better distance-corrected near and intermediate visual acuity. Conclusions: The reduction of total spherical aberration after aspheric IOL implantation may degrade distance-corrected near and intermediate visual acuity.
引用
收藏
页码:2050 / 2054
页数:5
相关论文
共 22 条
  • [1] Altmann Griffith E, 2004, Curr Opin Ophthalmol, V15, P358, DOI 10.1097/00055735-200408000-00013
  • [2] Evidence for delayed presbyopia after photorefractive keratectomy for myopia
    Artola, A
    Patel, S
    Schimchak, P
    Ayala, MJ
    Ruiz-Moreno, JM
    Alió, JL
    [J]. OPHTHALMOLOGY, 2006, 113 (05) : 735 - 741
  • [3] OPTICAL DESIGN OF INTRAOCULAR LENSES .1. ON-AXIS PERFORMANCE
    ATCHISON, DA
    [J]. OPTOMETRY AND VISION SCIENCE, 1989, 66 (08) : 492 - 506
  • [4] Bellucci R, 2004, J REFRACT SURG, V20, P297
  • [5] Cantú R, 2005, J REFRACT SURG, V21, pS603
  • [6] A population study on changes in wave aberrations with accommodation
    Cheng, H
    Barnett, JK
    Vilupuru, AS
    Marsack, JD
    Kasthurirangan, S
    Applegate, RA
    Roorda, A
    [J]. JOURNAL OF VISION, 2004, 4 (04): : 272 - 280
  • [7] DATILES MB, 1990, OPHTHALMOLOGY, V97, P922
  • [8] Apparent accommodation and depth of field in pseudophakia
    Elder, MJ
    Murphy, C
    Sanderson, GF
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (05) : 615 - 619
  • [9] Relationship between apparent accommodation and corneal multifocality in pseudophakic eyes
    Fukuyama, M
    Oshika, T
    Amano, S
    Yoshitomi, F
    [J]. OPHTHALMOLOGY, 1999, 106 (06) : 1178 - 1181