An electromagnetic calorimeter with a transversal orientation of the scintillating fibers

被引:0
|
作者
Bashmakov, YA
Gorbov, LA
Korbut, MS
Lebedev, AI
Lytkin, LK
Rusakov, SV
机构
[1] Russian Acad Sci, PN Lebedev Phys Inst, Moscow 119991, Russia
[2] Joint Inst Nucl Res, Dubna 141980, Moscow Oblast, Russia
关键词
Physical Chemistry; Calorimeter; Main Parameter; Energy Resolution; Measured Energy;
D O I
10.1023/A:1025117712358
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The space and energy resolutions of the SPACAL electromagnetic calorimeter with a transverse orientation of the scintillating fibers have been measured. The main parameters of the calorimeter are presented. The results of experiments with an electron test beam of the DESY synchrotron at energies E = 1-6 GeV are discussed. The measured energy resolution of the calorimeter is found to be (sigma/E) = 12.7%/ rootE + 2.0% (E is expressed in terms of GeV), and the space resolution is sigma(x,y)(E) = 1 mm at E = 4 GeV.
引用
收藏
页码:462 / 466
页数:5
相关论文
共 50 条
  • [1] An Electromagnetic Calorimeter with a Transversal Orientation of the Scintillating Fibers
    Yu. A. Bashmakov
    L. A. Gorbov
    M. S. Korbut
    A. I. Lebedev
    L. K. Lytkin
    S. V. Rusakov
    Instruments and Experimental Techniques, 2003, 46 : 462 - 466
  • [2] Optimization of the structure of an electromagnetic calorimeter with longitudinal arrangement of absorbing and scintillating layers
    Korablev, AV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2002, 45 (01) : 6 - 8
  • [3] Optimization of the Structure of an Electromagnetic Calorimeter with Longitudinal Arrangement of Absorbing and Scintillating Layers
    A. V. Korablev
    Instruments and Experimental Techniques, 2002, 45 : 6 - 8
  • [4] Study on angular resolution of lead-scintillating fiber electromagnetic calorimeter
    Wang, XB
    Chen, GM
    Li, ZH
    Chen, G
    Yang, M
    Yang, ZY
    Zhang, SH
    Lu, YS
    Chen, HS
    Li, XQ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (11): : 1071 - 1076
  • [5] Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter
    Li Zu-Hao
    Wang Ling-Yu
    Xu Wei-Wei
    Chen Guo-Ming
    Lu Yu-Sheng
    Chen He-Sheng
    CHINESE PHYSICS C, 2013, 37 (02)
  • [6] Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter
    李祖豪
    王玲玉
    许伟伟
    陈国明
    吕雨生
    陈和生
    Chinese Physics C, 2013, 37 (02) : 68 - 71
  • [7] Studies on high energy γ trigger of lead-scintillating fiber electromagnetic calorimeter
    Yang, ZY
    Chen, GM
    Chen, G
    Yang, M
    Wang, XB
    Liu, ZH
    Zhang, SH
    Lü, YS
    Chen, HS
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (10): : 1086 - 1089
  • [8] Performance of the PrimEx electromagnetic calorimeter
    Kubantsev, M.
    Larin, I.
    Gasparian, A.
    CALORIMETRY IN HIGH ENERGY PHYSICS, 2006, 867 : 51 - +
  • [9] The CMS electromagnetic calorimeter
    Paramatti, R
    IFAE 2005: 17th Italian Meeting on High Energy Physics, 2005, 794 : 291 - 294
  • [10] The CMS electromagnetic calorimeter
    Paganoni, Marco
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (03) : 574 - 577