An Internet of Things Sensor Array for Spatially and Temporally Resolved Indoor Climate Measurements

被引:1
作者
Rusch, Alexander [1 ]
Roesgen, Thomas [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Fluid Dynam, CH-8092 Zurich, Switzerland
关键词
COVID-19; pandemic; CO2; measurement; airborne transmission; indoor climate sensing; internet of things; wireless sensor array; ultra-wideband ranging; AIR-QUALITY; ENVIRONMENT; NETWORK; SYSTEM; BUILDINGS; CO2;
D O I
10.3390/s22124377
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The COVID-19 pandemic has emphasized the need for infection risk analysis and assessment of ventilation systems in indoor environments based on air quality criteria. In this context, simulations and direct measurements of CO2 concentrations as a proxy for exhaled air can help to shed light on potential aerosol pathways. While the former typically lack accurate boundary conditions as well as spatially and temporally resolved validation data, currently existing measurement systems often probe rooms in non-ideal, single locations. Addressing both of these issues, a large and flexible wireless array of 50 embedded sensor units is presented that provides indoor climate metrics with configurable spatial and temporal resolutions at a sensor response time of 20 s. Augmented by an anchorless self-localization capability, three-dimensional air quality maps are reconstructed up to a mean 3D Euclidean error of 0.21 m. Driven by resolution, ease of use, and fault tolerance requirements, the system has proven itself in day-to-day use at ETH Zurich, where topologically differing auditoria (at-grade, sloped) were investigated under real occupancy conditions. The corresponding results indicate significant spatial and temporal variations in the indoor climate rendering large sensor arrays essential for accurate room assessments. Even in well-ventilated auditoria, cleanout time constants exceeded 30 min.
引用
收藏
页数:23
相关论文
共 44 条
  • [1] A Cost-Effective Wireless Sensor Network System for Indoor Air Quality Monitoring Applications
    Abraham, Sherin
    Li, Xinrong
    [J]. 9TH INTERNATIONAL CONFERENCE ON FUTURE NETWORKS AND COMMUNICATIONS (FNC'14) / THE 11TH INTERNATIONAL CONFERENCE ON MOBILE SYSTEMS AND PERVASIVE COMPUTING (MOBISPC'14) / AFFILIATED WORKSHOPS, 2014, 34 : 165 - 171
  • [2] Wireless Sensor Network Combined with Cloud Computing for Air Quality Monitoring
    Arroyo, Patricia
    Luis Herrero, Jose
    Ignacio Suarez, Jose
    Lozano, Jesus
    [J]. SENSORS, 2019, 19 (03):
  • [3] An indoor environment monitoring system using low-cost sensor network
    Bamodu, Olileke
    Xia, Liang
    Tang, Llewellyn
    [J]. POWER AND ENERGY SYSTEMS ENGINEERING, (CPESE 2017), 2017, 141 : 660 - 666
  • [4] Effects of ventilation on the indoor spread of COVID-19
    Bhagat, Rajesh K.
    Davies Wykes, M. S.
    Dalziel, Stuart B.
    Linden, P. F.
    [J]. JOURNAL OF FLUID MECHANICS, 2020, 903
  • [5] Bhattacharya S, 2012, I CONF SENS TECHNOL, P422, DOI 10.1109/ICSensT.2012.6461713
  • [6] Ventilation and air cleaning to limit aerosol particle concentrations in a gym during the COVID-19 pandemic
    Blocken, B.
    van Druenen, T.
    Ricci, A.
    Kang, L.
    van Hooff, T.
    Qin, P.
    Xia, L.
    Ruiz, C. Alanis
    Arts, J. H.
    Diepens, J. F. L.
    Maas, G. A.
    Gillmeier, S. G.
    Vos, S. B.
    Brombacher, A. C.
    [J]. BUILDING AND ENVIRONMENT, 2021, 193
  • [7] bosch-sensortec, BMP390 DIGITAL PRESS
  • [8] Brunelli D, 2014, 2014 IEEE WORKSHOP ON ENVIRONMENTAL ENERGY AND STRUCTURAL MONITORING SYSTEMS (EESMS), P175
  • [9] EnergyPlus and CHAMPS-Multizone co-simulation for energy and indoor air quality analysis
    Chen, Yixing
    Gu, Lixing
    Zhang, Jianshun
    [J]. BUILDING SIMULATION, 2015, 8 (04) : 371 - 380
  • [10] de Leeuw J, 2009, J STAT SOFTW, V31, P1