Influence of microneedle shape on the transport of a fluorescent dye into human skin in vivo

被引:71
作者
Bal, Suzanne M. [2 ]
Kruithof, Annelieke C. [2 ]
Zwier, Raphael [3 ]
Dietz, Ekkehart [4 ]
Bouwstra, Joke A. [2 ]
Lademann, Juergen [1 ]
Meinke, Martina C. [1 ]
机构
[1] Charite, Dept Dermatol, Ctr Expt & Appl Cutaneous Physiol, D-10117 Berlin, Germany
[2] Leiden Univ, Div Drug Delivery Technol, Leiden Amsterdam Ctr Drug Res, NL-2300 RA Leiden, Netherlands
[3] Leiden Univ, Fine Mech Dept, NL-2300 RA Leiden, Netherlands
[4] Charite, Inst Med Biometr & Clin Epidemiol, D-10117 Berlin, Germany
关键词
Microneedles; In vivo visualisation; Confocal laser scanning microscopy; Transport; TRANSDERMAL DRUG-DELIVERY; LASER-SCANNING MICROSCOPY; IMMUNIZATION; ARRAYS; NANOPARTICLES; INSERTION; SAFETY;
D O I
10.1016/j.jconrel.2010.07.104
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Microneedles can enhance the penetration of vaccines into the skin for transcutaneous vaccination. In this study for the first time the influence of microneedle geometry on the transport through the formed conduits was visualised in human volunteers by confocal laser scanning microscopy. Three differently shaped 300 mu m long microneedle arrays were selected and fluorescein was applied either before or after piercing. Based on the intensity a distinction was made between regions with high and low intensity fluorescence (HIF and LIF). The areas of both intensities were quantified over time. In most cases HIF areas were only present in the stratum corneum, while LIF areas were also present in the viable epidermis. The areas were larger if fluorescein was applied after piercing compared to before piercing. After 15 min almost no HIF was present anymore at the skin surface. The microneedle geometry, but not the manner of application affected the shape and depth of the conduits. In conclusion we showed that the different microneedle arrays are able to form conduits in the skin, but the geometry of the microneedles influences the penetration of the fluorescent dye. This is the first step towards a more rational design of microneedle arrays for transcutaneous vaccination. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 224
页数:7
相关论文
共 29 条
[1]   Skin penetration enhancement by a microneedle device (Dermaroller®) in vitro: Dependency on needle size and applied formulation [J].
Badran, M. M. ;
Kuntsche, J. ;
Fahr, A. .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 36 (4-5) :511-523
[2]   In vivo visualization of microneedle conduits in human skin using laser scanning microscopy [J].
Bal, S. ;
Kruithof, A. C. ;
Liebl, H. ;
Tomerius, M. ;
Bouwstra, J. ;
Lademann, J. ;
Meinke, M. .
LASER PHYSICS LETTERS, 2010, 7 (03) :242-246
[3]   In vivo assessment of safety of microneedle arrays in human skin [J].
Bal, Suzanne M. ;
Caussin, Julia ;
Pavel, Stan ;
Bouwstra, Joke A. .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 35 (03) :193-202
[4]  
Banga AK, 2009, EXPERT OPIN DRUG DEL, V6, P343, DOI [10.1517/17425240902841935, 10.1517/17425240902841935 ]
[5]   Microneedle mediated delivery of nanoparticles into human skin [J].
Coulman, Sion A. ;
Anstey, Alexander ;
Gateley, Chris ;
Morrissey, Anthony ;
McLoughlin, Peter ;
Allender, Chris ;
Birchall, James C. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2009, 366 (1-2) :190-200
[6]   Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force [J].
Davis, SP ;
Landis, BJ ;
Adams, ZH ;
Allen, MG ;
Prausnitz, MR .
JOURNAL OF BIOMECHANICS, 2004, 37 (08) :1155-1163
[7]   Microneedle arrays for the transcutaneous immunization of diphtheria and influenza in BALB/c mice [J].
Ding, Z. ;
Verbaan, F. J. ;
Bivas-Benita, M. ;
Bungener, L. ;
Huckriede, A. ;
van den Berg, D. J. ;
Kersten, G. ;
Bouwstra, J. A. .
JOURNAL OF CONTROLLED RELEASE, 2009, 136 (01) :71-78
[8]   Immune Modulation by Adjuvants Combined with Diphtheria Toxoid Administered Topically in BALB/c Mice After Microneedle Array Pretreatment [J].
Ding, Z. ;
Van Riet, E. ;
Romeijn, S. ;
Kersten, G. F. A. ;
Jiskoot, W. ;
Bouwstra, J. A. .
PHARMACEUTICAL RESEARCH, 2009, 26 (07) :1635-1643
[9]   Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro [J].
Donnelly, Ryan F. ;
Singh, Thakur Raghu Raj ;
Tunney, Michael M. ;
Morrow, Desmond I. J. ;
McCarron, Paul A. ;
O'Mahony, Conor ;
Woolfson, A. David .
PHARMACEUTICAL RESEARCH, 2009, 26 (11) :2513-2522
[10]   Effect of microneedle design on pain in human volunteers [J].
Gill, Harvinder S. ;
Denson, Donald D. ;
Burris, Brett A. ;
Prausnitz, Mark R. .
CLINICAL JOURNAL OF PAIN, 2008, 24 (07) :585-594