Development of wavelength calibration techniques for high-resolution x-ray imaging crystal spectrometers on the EAST tokamak

被引:12
|
作者
Lyu, B. [1 ]
Chen, J. [1 ,2 ]
Hu, R. J. [1 ,2 ]
Delgado-Aparicio, L. F. [3 ]
Wang, F. D. [1 ]
Bitter, M. [3 ]
Hill, K. W. [3 ]
Pablant, N. [3 ]
Lee, S. G. [4 ]
Ye, M. Y. [2 ]
Shi, Y. J. [5 ]
Wan, B. N. [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Engn & Appl Phys, Hefei 230026, Anhui, Peoples R China
[3] Princeton Plasma Phys Lab, POB 451, Princeton, NJ 08543 USA
[4] Natl Fus Res Inst, Daejeon 305333, South Korea
[5] Seoul Natl Univ, Dept Nucl Engn, Seoul 151742, South Korea
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 10期
关键词
D O I
10.1063/1.5039314
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Newly developed large-area pixelated two-dimensional detector and two-crystal assemblies were deployed for the first time on tokamaks to enable time-resolved Bragg-diffracted x-ray imaging with good framing rate and water-cooling capabilities for in-vacuum long-pulse operations. High-quality helium-like (He-like) and hydrogen-like (H-like) argon spectra have been observed simultaneously for the first time on a single detector for a wide range of plasma parameters to infer both ion temperature and rotation profiles and support studies on spontaneous rotation, impurity transport, and RF physics. Since tokamak plasmas rotate in both the poloidal (theta) and toroidal (phi) directions, a reliable wavelength calibration is needed to account for the correct Doppler shift as well as to compute the spectrometer's instrumental function. Ly(alpha) lines emitted from Cd x-ray tubes are proposed to be used as "markers" to provide an in situ calibration of the EAST's X-ray imaging crystal spectrometer systems measuring He-and H-like argon spectra. The first lab test indicated that the X-ray tube can excite strong Ly(alpha) lines at 15 kV voltage and 1 mA current when the crystal is shined for 10 min. Other indirect calibration methods using locked-mode discharge scenarios were also studied as complementary methods. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] CURVED CRYSTAL REFLECTION X-RAY SPECTROMETERS FOR TOKAMAK PLASMAS
    FRAENKEL, B
    GOELER, SV
    HORTON, R
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (09): : 1160 - 1160
  • [22] Imaging x-ray crystal spectrometers for KSTAR
    Lee, SG
    Bak, JG
    Bitter, M
    Moon, MK
    Nam, UW
    Jin, KC
    Kong, KN
    Seon, KI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1997 - 2000
  • [23] Temperature gradient analyzers for compact high-resolution X-ray spectrometers
    Ishikawa, D.
    Baron, A. Q. R.
    JOURNAL OF SYNCHROTRON RADIATION, 2010, 17 : 12 - 24
  • [24] Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers
    Hell, N.
    Beiersdorfer, P.
    Brown, G., V
    Lockard, T. E.
    Magee, E. W.
    Shepherd, R.
    Hoarty, D. J.
    Brown, C. R. D.
    Hill, M. P.
    Hobbs, L. M. R.
    James, S. F.
    Lynch, C.
    Caughey, T. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (04):
  • [25] A high-resolution imaging x-ray crystal spectrometer for high energy density plasmas
    Chen, Hui
    Bitter, M.
    Hill, K. W.
    Kerr, S.
    Magee, E.
    Nagel, S. R.
    Park, J.
    Schneider, M. B.
    Stone, G.
    Williams, G. J.
    Beiersdorfer, P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [26] Development of a high-resolution x-ray imaging system with a charge-coupled-device detector coupled with crystal x-ray magnifiers
    Sato, K
    Hasegawa, Y
    Kondo, K
    Miyazaki, K
    Matsushita, T
    Amemiya, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (12): : 4449 - 4456
  • [27] Design of the high-resolution soft X-ray imaging system on the Joint Texas Experimental Tokamak
    Li, Jianchao
    Ding, Yonghua
    Zhang, Xiaoqing
    Xiao, Zhengyu
    Zhuang, Ge
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [28] HIGH-RESOLUTION X-RAY SPECTROSCOPY FOR DIAGNOSTICS OF SINGLE TOKAMAK DISCHARGES
    KALLNE, E
    KALLNE, J
    PHYSICA SCRIPTA, 1983, T3 : 185 - 190
  • [29] Development of a digital X-ray imaging module for portable high-resolution imaging applications
    Cho, H
    Jeong, M
    Kim, S
    Lee, B
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2005, 46 (05) : 1096 - 1101
  • [30] XTOP: high-resolution X-ray diffraction and imaging
    Favre-Nicolin, Vincent
    Baruchel, Jose
    Renevier, Hubert
    Eymery, Joel
    Borbely, Andras
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2015, 48 : 620 - 620