Development of wavelength calibration techniques for high-resolution x-ray imaging crystal spectrometers on the EAST tokamak

被引:12
|
作者
Lyu, B. [1 ]
Chen, J. [1 ,2 ]
Hu, R. J. [1 ,2 ]
Delgado-Aparicio, L. F. [3 ]
Wang, F. D. [1 ]
Bitter, M. [3 ]
Hill, K. W. [3 ]
Pablant, N. [3 ]
Lee, S. G. [4 ]
Ye, M. Y. [2 ]
Shi, Y. J. [5 ]
Wan, B. N. [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Engn & Appl Phys, Hefei 230026, Anhui, Peoples R China
[3] Princeton Plasma Phys Lab, POB 451, Princeton, NJ 08543 USA
[4] Natl Fus Res Inst, Daejeon 305333, South Korea
[5] Seoul Natl Univ, Dept Nucl Engn, Seoul 151742, South Korea
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 10期
关键词
D O I
10.1063/1.5039314
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Newly developed large-area pixelated two-dimensional detector and two-crystal assemblies were deployed for the first time on tokamaks to enable time-resolved Bragg-diffracted x-ray imaging with good framing rate and water-cooling capabilities for in-vacuum long-pulse operations. High-quality helium-like (He-like) and hydrogen-like (H-like) argon spectra have been observed simultaneously for the first time on a single detector for a wide range of plasma parameters to infer both ion temperature and rotation profiles and support studies on spontaneous rotation, impurity transport, and RF physics. Since tokamak plasmas rotate in both the poloidal (theta) and toroidal (phi) directions, a reliable wavelength calibration is needed to account for the correct Doppler shift as well as to compute the spectrometer's instrumental function. Ly(alpha) lines emitted from Cd x-ray tubes are proposed to be used as "markers" to provide an in situ calibration of the EAST's X-ray imaging crystal spectrometer systems measuring He-and H-like argon spectra. The first lab test indicated that the X-ray tube can excite strong Ly(alpha) lines at 15 kV voltage and 1 mA current when the crystal is shined for 10 min. Other indirect calibration methods using locked-mode discharge scenarios were also studied as complementary methods. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] High-resolution imaging X-ray spectrometers
    Strüder, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 454 (01): : 73 - 113
  • [2] X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers
    Shah, K.
    Delgado-Aparicio, L.
    Kraus, B. F.
    Ono, M.
    Gao, L.
    Umbach, B.
    Perkins, L.
    Pablant, N.
    Hill, K. W.
    Bitter, M.
    Teall, S.
    Drake, R.
    Schmidt, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (09):
  • [3] Upgrades of imaging x-ray crystal spectrometers for high-resolution and high-temperature plasma diagnostics on EAST
    Lyu, B.
    Wang, F. D.
    Pan, X. Y.
    Chen, J.
    Fu, J.
    Li, Y. Y.
    Bitter, M.
    Hill, K. W.
    Delgado-Aparicio, L. F.
    Pablant, N.
    Lee, S. G.
    Shi, Y. J.
    Ye, M. Y.
    Wan, B. N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [4] High-resolution imaging silicon X-ray spectrometers
    Strüder, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (1-2): : 146 - 146
  • [5] Upgrades of the high resolution imaging x-ray crystal spectrometers on experimental advanced superconducting tokamak
    Lu, B.
    Wang, F.
    Shi, Y.
    Bitter, M.
    Hill, K. W.
    Lee, S. G.
    Fu, J.
    Li, Y.
    Wan, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [6] Broadband High-Resolution Imaging Spectrometers for the Soft X-Ray Range
    Kolesnikov, A. O.
    Kuzin, A. A.
    Negrov, D. V.
    Ragozin, E. N.
    Sasorov, P. V.
    Shatokhin, A. N.
    Vishnyakov, E. A.
    X-RAY LASERS 2016, 2018, 202 : 389 - 393
  • [7] Wavelength calibration of x-ray imaging crystal spectrometer on Joint Texas Experimental Tokamak
    Yan, W.
    Chen, Z. Y.
    Jin, W.
    Huang, D. W.
    Ding, Y. H.
    Li, J. C.
    Zhang, X. Q.
    Lee, S. G.
    Shi, Y. J.
    Zhuang, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [8] HIGH-RESOLUTION X-RAY TECHNIQUES
    LAL, K
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1981, 19 (09) : 854 - 862
  • [9] Preliminary results of absolute wavelength calibration of imaging X-ray crystal spectrometer on EAST
    Pan, Xiayun
    Wang, Fudi
    Chen, Jun
    Lyu, Bo
    Li, Yingying
    Fu, Jia
    Xu, Liqing
    Shi, Yuejiang
    Ye, Minyou
    Wan, Baonian
    FUSION ENGINEERING AND DESIGN, 2015, 96-97 : 844 - 847
  • [10] HIGH-RESOLUTION HGL2 X-RAY SPECTROMETERS
    SWIERKOWSKI, SP
    ARMANTROUT, GA
    WICHNER, R
    APPLIED PHYSICS LETTERS, 1973, 23 (05) : 281 - 282