Quantitative targeted biomarker assay for glycated haemoglobin by multidimensional LC using mass spectrometric detection

被引:23
作者
del Castillo, Estela [1 ]
Montes-Bayon, Maria [1 ]
Anon, Elena [2 ]
Sanz-Medel, Alfredo [1 ]
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[2] Hosp Univ Cent Asturias, Biochem Lab, Oviedo 33006, Spain
关键词
Glycohaemoglobin; Multidimensional LC; Isotope dilution analysis; ICP-MS; BORONATE AFFINITY-CHROMATOGRAPHY; ISOTOPE-DILUTION ANALYSIS; HUMAN SERUM; ICP-MS; SPECIATION; GLYCOHEMOGLOBIN; STANDARDIZATION; PROTEINS;
D O I
10.1016/j.jprot.2010.07.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development of quantitative strategies for targeted biomarker analysis represents an urgent task especially in the field of clinical diagnosis. In this regard, the measurement of glycohaemoglobin (HbA(1c)) in blood has become the most specific way of monitoring long-term glycaemia in diabetic patients. Thus, there is an urgent need for methods that provide accurate and precise HbA(1c), results. A new method for the determination of HbA(1c) in blood samples based on the complementary use of multidimensional liquid chromatography (LC) and elemental (inductively coupled plasma mass spectrometry, ICP-MS) and molecular (electrospray-mass spectrometry, ESI-MS) MS techniques has been developed and validated. Different multidimensional separation possibilities by combining affinity and cation exchange chromatography have been explored for the adequate isolation of HbA(1c), which purity is addressed by ESI-MS. The workflow includes a final quantitative determination of HbA(1c), by elemental (Fe) isotope dilution analysis (IDA) with ICP-MS. For this purpose, the post-column addition of the isotopically labeled iron (Fe-57) has been used to quantify the eluting Fe-species from the column. The IDA methodology has been validated by analyzing a certified reference material and several samples from patients whose HbA(1c), levels were determined by a standard reference method. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 26 条
[1]   Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma [J].
Addona, Terri A. ;
Abbatiello, Susan E. ;
Schilling, Birgit ;
Skates, Steven J. ;
Mani, D. R. ;
Bunk, David M. ;
Spiegelman, Clifford H. ;
Zimmerman, Lisa J. ;
Ham, Amy-Joan L. ;
Keshishian, Hasmik ;
Hall, Steven C. ;
Allen, Simon ;
Blackman, Ronald K. ;
Borchers, Christoph H. ;
Buck, Charles ;
Cardasis, Helene L. ;
Cusack, Michael P. ;
Dodder, Nathan G. ;
Gibson, Bradford W. ;
Held, Jason M. ;
Hiltke, Tara ;
Jackson, Angela ;
Johansen, Eric B. ;
Kinsinger, Christopher R. ;
Li, Jing ;
Mesri, Mehdi ;
Neubert, Thomas A. ;
Niles, Richard K. ;
Pulsipher, Trenton C. ;
Ransohoff, David ;
Rodriguez, Henry ;
Rudnick, Paul A. ;
Smith, Derek ;
Tabb, David L. ;
Tegeler, Tony J. ;
Variyath, Asokan M. ;
Vega-Montoto, Lorenzo J. ;
Wahlander, Asa ;
Waldemarson, Sofia ;
Wang, Mu ;
Whiteaker, Jeffrey R. ;
Zhao, Lei ;
Anderson, N. Leigh ;
Fisher, Susan J. ;
Liebler, Daniel C. ;
Paulovich, Amanda G. ;
Regnier, Fred E. ;
Tempst, Paul ;
Carr, Steven A. .
NATURE BIOTECHNOLOGY, 2009, 27 (07) :633-U85
[2]   The emerging role of ICP-MS in proteomic analysis [J].
Bettmer, Joerg ;
Montes Bayon, Maria ;
Ruiz Encinar, Jorge ;
Fernandez Sanchez, Maria Luisa ;
del Rosario Fernandez de la Campa, Maria ;
Sanz Medel, Alfredo .
JOURNAL OF PROTEOMICS, 2009, 72 (06) :989-1005
[3]  
Bry L, 2001, CLIN CHEM, V47, P153
[4]   NON-ENZYMATIC GLYCOSYLATION OF PROTEIN - RELEVANCE TO DIABETES [J].
BUNN, HF .
AMERICAN JOURNAL OF MEDICINE, 1981, 70 (02) :325-330
[5]  
Cabezuelo ABS, 1998, ANALYST, V123, P865
[6]   Simultaneous determination of glycated haemoglobin, a long term biomarker of diabetes mellitus, and total haemoglobin by isotope dilution and HPLC-ICP-MS [J].
del Castillo Busto, M. Estela ;
Montes-Bayon, Maria ;
Anon, Elena ;
Sanz-Medel, Alfredo .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (05) :758-764
[7]   Preparation of a candidate primary reference material for the international standardisation of HbA1c determinations [J].
Finke, A ;
Kobold, U ;
Hoelzel, W ;
Weykamp, C ;
Miedema, K ;
Jeppsson, JO .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (05) :299-308
[8]   Consensus statement on the worldwide standardization of the hemoglobin A1C measurement - The American Diabetes Association, European Association for the Study of Diabetes, International Federation of Clinical Chemistry and Laboratory Medicine, and the International Diabetes Federation [J].
Hicks, Jocelyn ;
Muller, Mathias ;
Panteghini, Mauro ;
John, Garry ;
Deeb, Larry ;
Buse, John ;
Nathan, David M. ;
Kahn, Richard ;
Ferrannini, Ele ;
Heine, Robert ;
Silink, Martin ;
Mbanya, Jean-Claude .
DIABETES CARE, 2007, 30 (09) :2399-2400
[9]   IFCC reference system for measurement of hemoglobin Alc in human blood and the National Standardization Schemes in the United States, Japan, and Sweden:: A method-comparison study [J].
Hoelzel, W ;
Weykamp, C ;
Jeppsson, JO ;
Miedema, K ;
Barr, JR ;
Goodall, I ;
Hoshino, T ;
John, WG ;
Kobold, U ;
Little, R ;
Mosca, A ;
Mauri, P ;
Paroni, R ;
Susanto, F ;
Takei, I ;
Thienpont, L ;
Umemoto, M ;
Wiedmeyer, HM .
CLINICAL CHEMISTRY, 2004, 50 (01) :166-174
[10]  
ICSH, 1978, ICSH STANDARD CLIN P, V31, P139