Reproducibility of quantitative optical coherence tomography subanalysis in neovascular age-related macular degeneration

被引:91
作者
Joeres, Sandra
Tsong, Jerry W.
Updike, Paul G.
Collins, Allyson T.
Dustin, Laurie
Walsh, Alexander C.
Romano, Peggy W.
Sadda, SriniVas R.
机构
[1] Doheny Eye Inst, Los Angeles, CA 90033 USA
[2] Univ So Calif, Keck Sch Med, Doheny Eye Inst, Doheny Image Reading Ctr, Los Angeles, CA USA
[3] Univ So Calif, Keck Sch Med, Doheny Eye Inst, Dept Prevent Med, Los Angeles, CA USA
关键词
D O I
10.1167/iovs.07-0179
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the intergrader reproducibility for computer-assisted grading of optical coherence tomography (OCT) images in eyes with neovascular age-related macular degeneration (AMD), by using a standardized grading procedure. METHODS. Sixty OCT image sets ( of six radial lines each) were independently analyzed by two graders using validated custom software (OCTOR) to draw boundaries manually on OCT B-scans. Spaces delineated by these boundaries included retina, subretinal fluid, subretinal tissue, and pigment epithelial detachments (PEDs). Volume measurements for the nine Early Treatment of Diabetic Retinopathy Study (ETDRS) subfields and the mean foveal center point (FCP) thickness were calculated by the software and compared by using weighted kappa statistics and intraclass correlation coefficients (ICCs). RESULTS. Intergrader comparison of the foveal central subfield (FCS) volume, total volume, and mean FCP thickness showed a high level of agreement and strong correlation between measurements for all spaces (kappa(weighted) = 0.72-0.97; ICC = 0.92-0.99). The best agreement was observed for total volume of the combination of all four graded spaces (kappa(weighted) = 0.97, mean difference = 0.31 mm(3), or 2.51%). The highest ICCs were seen for FCP thickness measurements. The poorest agreement was found for grading of subretinal tissue. Eyes with advanced choroidal neovascularization (CNV) and poor visibility of the retinal pigment epithelium (RPE) band appeared to show the greatest intergrader discrepancies. CONCLUSIONS. Analysis of OCT images by trained graders using computer-assisted grading software allows for highly reproducible quantitative measurements, even in eyes with complex diseases such as neovascular AMD. Quantitative subanalysis may be useful in studying the differential morphologic effect of therapies on various anatomic components.
引用
收藏
页码:4300 / 4307
页数:8
相关论文
共 26 条
  • [21] SCHUMAN JS, 2004, OPTICAL COHERENCE TO
  • [22] A comparison of retinal morphology viewed by optical coherence tomography and by light microscopy
    Toth, CA
    Narayan, DG
    Boppart, SA
    Hee, MR
    Fujimoto, JG
    Birngruber, R
    Cain, CP
    DiCarlo, CD
    Roach, WP
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (11) : 1425 - 1428
  • [23] Voo Irene, 2004, Ophthalmol Clin North Am, V17, P21, DOI 10.1016/j.ohc.2003.12.002
  • [24] Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography
    Wojtkowski, M
    Srinivasan, V
    Fujimoto, JG
    Ko, T
    Schuman, JS
    Kowalczyk, A
    Duker, JS
    [J]. OPHTHALMOLOGY, 2005, 112 (10) : 1734 - 1746
  • [25] Ophthalmic imaging by spectral optical coherence tomography.
    Wojtkowski, M
    Bajraszewski, T
    Gorczynska, I
    Targowski, P
    Kowalczyk, A
    Wasilewski, W
    Radzewicz, C
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (03) : 412 - 419
  • [26] Adaptive-optics optical coherence tomography for high-resolution and high-speed 3D retinal in vivo imaging
    Zawadzki, RJ
    Jones, SM
    Olivier, SS
    Zhao, MT
    Bower, BA
    Izatt, JA
    Choi, S
    Laut, S
    Werner, JS
    [J]. OPTICS EXPRESS, 2005, 13 (21): : 8532 - 8546