Deep artifact suppression for spiral real-time phase contrast cardiac magnetic resonance imaging in congenital heart disease

被引:8
|
作者
Jaubert, Olivier [1 ,2 ]
Steeden, Jennifer [2 ]
Montalt-Tordera, Javier [2 ]
Arridge, Simon [1 ]
Kowalik, Grzegorz Tomasz [2 ]
Muthurangu, Vivek [2 ]
机构
[1] UCL, Dept Comp Sci, London WC1E 6BT, England
[2] UCL, Ctr Cardiovasc Imaging, Inst Cardiovasc Sci, London WC1N 1EH, England
基金
英国工程与自然科学研究理事会;
关键词
Cardiac MRI; Congenital heart disease; Real time; Flow imaging; Image reconstruction; Machine learning; MRI;
D O I
10.1016/j.mri.2021.08.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Real-time spiral phase contrast MR (PCMR) enables rapid free-breathing assessment of flow. Target spatial and temporal resolutions require high acceleration rates often leading to long reconstruction times. Here we propose a deep artifact suppression framework for fast and accurate flow quantification. Methods: U-Nets were trained for deep artifact suppression using 520 breath-hold gated spiral PCMR aortic datasets collected in congenital heart disease patients. Two spiral trajectories (uniform and perturbed) and two losses (Mean Absolute Error -MAE- and average structural similarity index measurement -SSIM-) were compared in synthetic data in terms of MAE, peak SNR (PSNR) and SSIM. Perturbed spiral PCMR was prospectively acquired in 20 patients. Stroke Volume (SV), peak mean velocity and edge sharpness measurements were compared to Compressed Sensing (CS) and Cartesian reference. Results: In synthetic data, perturbed spiral consistently outperformed uniform spiral for the different image metrics. U-Net MAE showed better MAE and PSNR while U-Net SSIM showed higher SSIM based metrics. In-vivo, there were no significant differences in SV between any of the real-time reconstructions and the reference standard Cartesian data. However, U-Net SSIM had better image sharpness and lower biases for peak velocity when compared to U-Net MAE. Reconstruction of 96 frames took similar to 59 s for CS and 3.9 s for U-Nets. Conclusion: Deep artifact suppression of complex valued images using an SSIM based loss was successfully demonstrated in a cohort of congenital heart disease patients for fast and accurate flow quantification.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
  • [41] Accelerated Phase Contrast Magnetic Resonance Imaging via Deep Learning
    Nath, Ruponti
    Callahan, Sean
    Singam, Narayana
    Stoddard, Marcus
    Amini, Amir A.
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 834 - 838
  • [42] First experience with real-time magnetic resonance imaging-based investigation of respiratory influence on cardiac function in pediatric congenital heart disease patients with chronic right ventricular volume overload
    Lena Maria Röwer
    Karl Ludger Radke
    Janina Hußmann
    Halima Malik
    Monika Eichinger
    Dirk Voit
    Mark Oliver Wielpütz
    Jens Frahm
    Dirk Klee
    Frank Pillekamp
    Pediatric Radiology, 2023, 53 : 2608 - 2621
  • [43] In vitro real-time magnetic resonance imaging for quantification of thrombosis
    Yang, Ling
    Neuberger, Thomas
    Manning, Keefe B.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (02) : 285 - 295
  • [44] Magnetic resonance imaging, ultrasound and real-time ultrasound elastography of the thigh muscles in congenital muscle dystrophy
    Drakonaki, Eleni E.
    Allen, Gina M.
    SKELETAL RADIOLOGY, 2010, 39 (04) : 391 - 396
  • [45] AUTOMATIC EXTRACTION AND SIGN DETERMINATION OF RESPIRATORY SIGNAL IN REAL-TIME CARDIAC MAGNETIC RESONANCE IMAGING
    Chen, Chong
    Liu, Yingmin
    Simonetti, Orlando P.
    Ahmad, Rizwan
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 830 - 833
  • [46] Real-Time Magnetic Resonance Imaging Guidance for Cardiovascular Procedures
    Horvath, Keith A.
    Li, Ming
    Mazilu, Dumitru
    Guttman, Michael A.
    McVeigh, Elliot R.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2007, 19 (04) : 330 - 335
  • [47] Magnetic resonance imaging, ultrasound and real-time ultrasound elastography of the thigh muscles in congenital muscle dystrophy
    Eleni E. Drakonaki
    Gina M. Allen
    Skeletal Radiology, 2010, 39 : 391 - 396
  • [48] Contribution of fetal magnetic resonance imaging in fetuses with congenital heart disease
    Luis F. Goncalves
    Christopher L. Lindblade
    Patricia Cornejo
    Mittun C. Patel
    Ericka Scheller McLaughlin
    Dianna M. E. Bardo
    Pediatric Radiology, 2022, 52 : 513 - 526
  • [49] Blood flow measurement by magnetic resonance imaging in congenital heart disease
    Powell, AJ
    Geva, T
    PEDIATRIC CARDIOLOGY, 2000, 21 (01) : 47 - 58
  • [50] Morphologic and functional evaluation of congenital heart disease by magnetic resonance imaging
    Didier, D
    Ratib, O
    Beghetti, M
    Oberhaensli, I
    Friedli, B
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (05) : 639 - 655