Deep artifact suppression for spiral real-time phase contrast cardiac magnetic resonance imaging in congenital heart disease

被引:8
|
作者
Jaubert, Olivier [1 ,2 ]
Steeden, Jennifer [2 ]
Montalt-Tordera, Javier [2 ]
Arridge, Simon [1 ]
Kowalik, Grzegorz Tomasz [2 ]
Muthurangu, Vivek [2 ]
机构
[1] UCL, Dept Comp Sci, London WC1E 6BT, England
[2] UCL, Ctr Cardiovasc Imaging, Inst Cardiovasc Sci, London WC1N 1EH, England
基金
英国工程与自然科学研究理事会;
关键词
Cardiac MRI; Congenital heart disease; Real time; Flow imaging; Image reconstruction; Machine learning; MRI;
D O I
10.1016/j.mri.2021.08.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Real-time spiral phase contrast MR (PCMR) enables rapid free-breathing assessment of flow. Target spatial and temporal resolutions require high acceleration rates often leading to long reconstruction times. Here we propose a deep artifact suppression framework for fast and accurate flow quantification. Methods: U-Nets were trained for deep artifact suppression using 520 breath-hold gated spiral PCMR aortic datasets collected in congenital heart disease patients. Two spiral trajectories (uniform and perturbed) and two losses (Mean Absolute Error -MAE- and average structural similarity index measurement -SSIM-) were compared in synthetic data in terms of MAE, peak SNR (PSNR) and SSIM. Perturbed spiral PCMR was prospectively acquired in 20 patients. Stroke Volume (SV), peak mean velocity and edge sharpness measurements were compared to Compressed Sensing (CS) and Cartesian reference. Results: In synthetic data, perturbed spiral consistently outperformed uniform spiral for the different image metrics. U-Net MAE showed better MAE and PSNR while U-Net SSIM showed higher SSIM based metrics. In-vivo, there were no significant differences in SV between any of the real-time reconstructions and the reference standard Cartesian data. However, U-Net SSIM had better image sharpness and lower biases for peak velocity when compared to U-Net MAE. Reconstruction of 96 frames took similar to 59 s for CS and 3.9 s for U-Nets. Conclusion: Deep artifact suppression of complex valued images using an SSIM based loss was successfully demonstrated in a cohort of congenital heart disease patients for fast and accurate flow quantification.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
  • [31] Yield of Cardiac Magnetic Resonance Imaging as an Adjunct to Echocardiography in Young Infants With Congenital Heart Disease
    Joyce T. Johnson
    Kimberly M. Molina
    Molly McFadden
    L. LuAnn Minich
    Shaji C. Menon
    Pediatric Cardiology, 2014, 35 : 1067 - 1071
  • [32] Contrast-enhanced magnetic resonance angiography in congenital heart disease
    Marin Rodriguez, C.
    Maroto Alvaro, E.
    Sanchez Alegre, M. L.
    Ruiz Martin, Y.
    Delgado Carrasco, J.
    RADIOLOGIA, 2009, 51 (03): : 261 - 272
  • [33] Yield of Cardiac Magnetic Resonance Imaging as an Adjunct to Echocardiography in Young Infants With Congenital Heart Disease
    Johnson, Joyce T.
    Molina, Kimberly M.
    McFadden, Molly
    Minich, L. LuAnn
    Menon, Shaji C.
    PEDIATRIC CARDIOLOGY, 2014, 35 (06) : 1067 - 1071
  • [34] 3 tesla magnetic resonance imaging in children and adults with congenital heart disease
    Voges, I.
    Jerosch-Herold, M.
    Helle, M.
    Hart, C.
    Kramer, H. -H.
    Rickers, C.
    RADIOLOGE, 2010, 50 (09): : 799 - +
  • [35] MAGNETIC-RESONANCE-IMAGING OF CONGENITAL HEART-DISEASE
    GUTIERREZ, FR
    TOPICS IN MAGNETIC RESONANCE IMAGING, 1995, 7 (04) : 246 - 257
  • [36] Multicenter retrospective evaluation of magnetic resonance imaging in pediatric and congenital heart disease patients with cardiac implantable electronic devices
    Gakenheimer-Smith, Lindsey
    Ou, Zhining
    Kuang, Jinqiu
    Moore, Jeremy P.
    Burrows, Austin
    Kovach, Joshua
    Dechert, Brynn
    Beach, Cheyenne M.
    Ayers, Mark
    Tan, Reina Bianca
    Mostafavifar, Mina
    Mah, Douglas Y.
    Conner, Tracy Marrs
    Turpin, Susan
    Avasarala, Kishor
    Shah, Maully J.
    Webster, Gregory
    Posey, Jessica
    Etheridge, Susan P.
    Binka, Edem
    Niu, Mary
    Asaki, S. Yukiko
    Lambert, Linda M.
    Pilcher, Thomas A.
    HEART RHYTHM, 2023, 20 (12) : 1752 - 1758
  • [37] First experience with real-time magnetic resonance imaging-based investigation of respiratory influence on cardiac function in pediatric congenital heart disease patients with chronic right ventricular volume overload
    Roewer, Lena Maria
    Radke, Karl Ludger
    Hussmann, Janina
    Malik, Halima
    Eichinger, Monika
    Voit, Dirk
    Wielpuetz, Mark Oliver
    Frahm, Jens
    Klee, Dirk
    Pillekamp, Frank
    PEDIATRIC RADIOLOGY, 2023, 53 (13) : 2608 - 2621
  • [38] Anatomical and functional imaging of congenital heart disease with phase contrast VIPR
    Christopher J Francois
    Elizabeth Nett
    Kevin M Johnson
    Darren Lum
    Scott B Reeder
    Oliver Wieben
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [39] Real-time color-flow CMR in adults with congenital heart disease
    de la Pena, Erasmo
    Nguyen, Patricia K.
    Nayak, Krishna S.
    Yang, Phillip C.
    Rosenthal, David N.
    Hu, Bob S.
    Pauly, John M.
    McConnell, Michael V.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (06) : 809 - 815
  • [40] Assessment of Cardiac Time Intervals Using High Temporal Resolution Real-Time Spiral Phase Contrast with UNFOLDed-SENSE
    Kowalik, Grzegorz T.
    Knight, Daniel S.
    Steeden, Jennifer A.
    Tann, Oliver
    Odille, Freddy
    Atkinson, David
    Taylor, Andrew
    Muthurangu, Vivek
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) : 749 - 756