Influence of macroporous gold support and its functionalization on lactate oxidase-based biosensors response

被引:32
作者
Gamero, M. [1 ]
Sosna, M. [3 ]
Pariente, F. [2 ]
Lorenzo, E. [2 ]
Bartlett, P. N. [3 ]
Alonso, C. [1 ]
机构
[1] Univ Autonoma Madrid, Dept Appl Phys Chem, E-28049 Madrid, Spain
[2] Univ Autonoma Madrid, Dept Analyt Chem, E-28049 Madrid, Spain
[3] Univ Southampton, Sch Chem, Southampton SO17 1BJ, Hants, England
关键词
Macroporous gold; Lactate oxidase; Biosensor; Modified electrodes; ELECTROCHEMICAL DEPOSITION; FILM ELECTRODE; ADSORPTION; TEMPLATES; PLATINUM;
D O I
10.1016/j.talanta.2012.03.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A general bioanalytical platform for biosensor applications was developed based on three-dimensional ordered macroporous (3DOM) gold film modified electrodes using lactate oxidase (LOx) as a case study, within the framework of developing approaches of broad applicability. The electrode was electrochemically fabricated with an inverted opal template, making the surface area of the 3DOM gold electrode up to 18 times higher than that of bare flat gold electrodes. These new electrochemical transducers were characterized by using Field Emission Scanning Electron Microscopy (FE-SEM), Atomic Force Microscopy (AFM) and the X-ray diffraction (XRD). The biosensor was developed by immobilization of lactate oxidase (LOx), on a 3DOM gold electrode modified with a self-assembled monolayer of dithiobis-N-succinimidyl propionate (DTSP). The resulting lactate oxidase biosensor was characterized by electrochemical impedance spectroscopy (EIS). The 3DOM gold electrode not only provides a good biocompatible microenvironment but also promotes the increase of conductivity and stability. Thus, the developed lactate oxidase bioanalytical platforms showed higher mediated bioelectrocatalytic activity compared to others previously described based on polycrystalline gold transducers. The response to varying lactate concentrations has been obtained in the presence of hydroxymethylferrocene as redox mediator in solution. Under these conditions, the bioanalytical platform response for DTSP covalently bound enzyme was improved with respect to that obtained in absence of DTSP. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:328 / 334
页数:7
相关论文
共 28 条
[11]   Nanostructured rough gold electrodes for the development of lactate oxidase-based biosensors [J].
Gamero, M. ;
Pariente, F. ;
Lorenzo, E. ;
Alonso, C. .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (09) :2038-2044
[12]   Prussian Blue- and lactate oxidase-based amperometric biosensor for lactic acid [J].
Garjonyte, R ;
Yigzaw, Y ;
Meskys, R ;
Malinauskas, A ;
Gorton, L .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) :33-38
[13]   Impedance spectroscopy of self-assembled monolayers on Au(111): Sodium ferrocyanide charge transfer at modified electrodes [J].
Janek, RP ;
Fawcett, WR ;
Ulman, A .
LANGMUIR, 1998, 14 (11) :3011-3018
[14]   Ionic-Liquid-Doped Polyaniline Inverse Opals: Preparation, Characterization, and Application for the Electrochemical Impedance Immunoassay of Hepatitis B Surface Antigen [J].
Li, Xing-Hua ;
Dai, Lin ;
Liu, Yan ;
Chen, Xiao-Jun ;
Yan, Wei ;
Jiang, Li-Ping ;
Zhu, Jun-Jie .
ADVANCED FUNCTIONAL MATERIALS, 2009, 19 (19) :3120-3128
[15]   Biosensors for clinical diagnostics industry [J].
Malhotra, BD ;
Chaubey, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) :117-127
[16]   Microscopic and voltammetric characterization of bioanalytical platforms based on lactate oxidase [J].
Parra, A. ;
Casero, E. ;
Vazquez, L. ;
Jin, J. ;
Pariente, F. ;
Lorenzo, E. .
LANGMUIR, 2006, 22 (12) :5443-5450
[17]   Design and characterization of a lactate biosensor based on immobilized lactate oxidase onto gold surfaces [J].
Parra, A ;
Casero, E ;
Vázquez, L ;
Pariente, F ;
Lorenzo, E .
ANALYTICA CHIMICA ACTA, 2006, 555 (02) :308-315
[18]   Fabrication and characterization of disposable type lactate oxidase sensors for dairy products and clinical analysis [J].
Patel, NG ;
Erlenkötter, A ;
Cammann, K ;
Chemnitius, GC .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :134-141
[19]   Preparation of three-dimensional ordered macroporous Prussian blue film electrode for glucose biosensor application [J].
Qiu, Jian-Ding ;
Peng, Hong-Zhen ;
Liang, Ru-Ping ;
Xiong, Meng .
ELECTROANALYSIS, 2007, 19 (11) :1201-1206
[20]   Graphite-Teflon composite bienzyme electrodes for the determination of L-lactate:: Application to food samples [J].
Serra, B ;
Reviejo, AJ ;
Parrado, C ;
Pingarrón, JM .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :505-513