Metabolic and kinematic responses while walking and running on a motorised and a curved non-motorised treadmill

被引:8
作者
Bruseghini, Paolo [1 ,2 ]
Tam, Enrico [2 ]
Monte, Andrea [2 ]
Capelli, Carlo [2 ,3 ]
Zamparo, Paola [2 ]
机构
[1] Univ Brescia, Dept Mol & Translat Med, Viale Europa 11, I-25123 Brescia, Italy
[2] Univ Verona, Dept Neurol & Movement Sci, Sch Sport & Exercise Sci, Verona, Italy
[3] Norwegian Sch Sport Sci, Dept Phys Performances, Oslo, Norway
关键词
Curved non-motorised treadmill; energy cost of running; energy cost of walking; kinematics; belt friction; ENERGY-COST; PERFORMANCE; RELIABILITY; VALIDITY; TIME;
D O I
10.1080/02640414.2018.1504605
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of this study was to assess metabolic and kinematic parameters (contact and flight time, step length and frequency) while walking at the preferred speed (1.44 +/- 0.22 m center dot s(-1)) and while performing an incremental running test (up to exhaustion) on a motorised treadmill (MT) and on a curved non-motorised treadmill (CNMT). Twenty-five volunteers (24.1 +/- 3.4 years; 64.7 +/- 11.2 kg) participated in the study. Maximal running speed on MT was significantly larger (P < 0.001) than on CNMT (4.31 +/- 0.50 vs. 3.75 +/- 0.39 m center dot s(-1)) but no differences in heart rate or oxygen uptake were observed at this speed. The energy cost of walking (C-w) and running (C-r) were significantly greater (P < 0.001) on CNMT than on MT (37 and 17%, respectively). No major differences in kinematic parameters were observed at paired, submaximal, running speeds (2.22-3.89 m center dot s(-1)) but was systematically larger in CNMT (of about 340 ml center dot min(-1) center dot kg(-1)). This systematic difference can be expressed in terms of a larger "equivalent speed" on CNMT (of about 0.42 m center dot s(-1)) and should be attributed to factors other than the kinematic ones, such as the belt characteristics (e.g. friction, type of surface and curvature).
引用
收藏
页码:396 / 403
页数:8
相关论文
共 24 条
[1]  
American College of Sports Medicine, 2014, GUID EX TEST PRESCR, P19
[2]  
[Anonymous], 2016, ACTA KINESIOLOGIAE U, DOI [DOI 10.12697/AKUT.2016.22.02, 10.12697/akut.2016.22.02]
[3]   A NEW METHOD FOR DETECTING ANAEROBIC THRESHOLD BY GAS-EXCHANGE [J].
BEAVER, WL ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (06) :2020-2027
[4]   DETERMINANTS OF TIME TO FATIGUE DURING NONMOTORIZED TREADMILL EXERCISE [J].
De Witt, John K. ;
Lee, Stuart M. C. ;
Wilson, Cassie A. ;
Hagan, R. Donald .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2009, 23 (03) :883-890
[5]   A simple method for assessing the energy cost of running during incremental tests [J].
di Prampero, Pietro Enrico ;
Salvadego, Desy ;
Fusi, Simonetta ;
Grassi, Bruno .
JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (04) :1068-1075
[6]   Non-motorized Treadmill Running Is Associated with Higher Cardiometabolic Demands Compared with Overground and Motorized Treadmill Running [J].
Edwards, Robert B. ;
Tofari, Paul J. ;
Cormack, Stuart J. ;
Whyte, Douglas G. .
FRONTIERS IN PHYSIOLOGY, 2017, 8
[7]  
Franks KA, 2012, J SPORT SCI MED, V11, P71
[8]  
Fullenkamp A. M., 2017, J SPORT REHABIL, V12, P1
[9]   THE RELATIONSHIP BETWEEN THE RESPIRATORY QUOTIENT AND THE ENERGY EQUIVALENT OF OXYGEN DURING SIMULTANEOUS GLUCOSE AND LIPID OXIDATION AND LIPOGENESIS [J].
GARBY, L ;
ASTRUP, A .
ACTA PHYSIOLOGICA SCANDINAVICA, 1987, 129 (03) :443-444
[10]  
Gonzalez AM, 2013, J SPORT SCI MED, V12, P104