Effects of Cold Stimulation on the Harmonic Structure of the Blood Pressure and Photoplethysmography Waveforms

被引:13
作者
Hsiu, Hsin [1 ]
Huang, Shih-Ming [2 ]
Hsu, Chia-Liang
Hu, Shih-Fan [2 ]
Lin, Hung-Wen [2 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Grad Inst Biomed Engn, Taipei 10607, Taiwan
[2] Yuan Ze Univ, Dept Elect Engn, Tao Yuan, Taiwan
关键词
SYMPATHETIC-NERVE ACTIVITY; VOLUME PULSE; FINGER; VARIABILITY; RESPONSES; EXPOSURE; DISEASE; SYSTEM; FLOW;
D O I
10.1089/pho.2011.3124
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Cold stimulation (CS) accompanied by vasoconstriction can increase the stiffness of the arterial system. The vascular responses during CS have been studied using photoplethysmography (PPG), but most have focused on time-domain waveform indexes. Focusing on the radial arterial blood pressure (BPW) and the finger PPG waveforms, we aimed to determine if harmonic index could help to noninvasively characterize the changes in arterial pulse transmission following mild CS. Methods: Trials were measured on male healthy volunteers (n = 29); mild CS was applied by placing a bag filled with 2000 cc of water at a temperature of 19-21 degrees C around the right lower arm. For each experiment, we recorded a 3-min baseline-data sequence, applied local mild CS and recorded a 3-min effect sequence, and then recorded another 3-min effect sequence immediately after stopping CS. BPW and PPG spectra were used to calculate the amplitude proportion (C-n) and phase angle (P-n) for each harmonic (for n = 1-10) from averages of all the pulses during the measurement period. Results: Several harmonic indexes were prominently increased following CS, including C-4-C-10 and P-3-P-10 for the BPW and C-5-C-10 and P-3 and P-4 for PPG waveforms. Conclusions: It was demonstrated that the application of mild CS significantly changes several harmonic-analysis indexes of the BPW and the PPG waveforms. By providing detailed information about the pulse transmission of each frequency component, harmonic analysis may improve the ability to detect arterial elastic properties induced by CS, other forms of external stimulation, or pathological factors. It may be pertinent to the development of medical devices for application in telemedicine.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 28 条
[11]   Radial augmentation index: A useful and easily obtainable parameter for vascular aging [J].
Kohara, K ;
Tabara, Y ;
Oshiumi, A ;
Miyawaki, Y ;
Kobayashi, T ;
Miki, T .
AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (01) :11S-14S
[12]   Arterial wave reflections and survival in end-stage renal failure [J].
London, GM ;
Blacher, J ;
Pannier, B ;
Guérin, AP ;
Marchais, SJ ;
Safar, ME .
HYPERTENSION, 2001, 38 (03) :434-438
[13]   Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method [J].
López-Beltrán, EA ;
Blackshear, PL ;
Finkelstein, SM ;
Cohn, JN .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (06) :748-753
[14]   Arterial stiffness and risk of coronary heart disease and stroke - The Rotterdam Study [J].
Mattace-Raso, FUS ;
van der Cammen, TJM ;
Hofman, A ;
van Popele, NM ;
Bos, ML ;
Schalekamp, MADH ;
Asmar, R ;
Reneman, RS ;
Hoeks, APG ;
Breteler, MMB ;
Witteman, JCM .
CIRCULATION, 2006, 113 (05) :657-663
[15]  
Milnor W.R., 1989, HEMODYNAMICS, V2nd
[16]   Pulse transit time by r-wave-gated infrared photoplethysmography: Review of the literature and personal experience [J].
Naschitz J.E. ;
Bezobchuk S. ;
Mussafia-Priselac R. ;
Sundick S. ;
Dreyfuss D. ;
Khorshidi I. ;
Karidis A. ;
Manor H. ;
Nagar M. ;
Peck E.R. ;
Peck S. ;
Storch S. ;
Rosner I. ;
Gaitini L. .
Journal of Clinical Monitoring and Computing, 2004, 18 (5-6) :333-342
[17]  
Nichols W.W., 1998, McDonald's Blood Flow in Arteries: Theoretical, experimental and clinical principles, V4th
[18]   Very low frequency variability in arterial blood pressure and blood volume pulse [J].
Nitzan, M ;
Babchenko, A ;
Khanokh, B .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (01) :54-58
[19]   Pulse wave analysis [J].
O'Rourke, MF ;
Pauca, A ;
Jiang, XJ .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2001, 51 (06) :507-522
[20]   INPUT IMPEDANCE OF SYSTEMIC CIRCULATION [J].
OROURKE, MF ;
TAYLOR, MG .
CIRCULATION RESEARCH, 1967, 20 (04) :365-&