Evaluation of pretilt angle and polar anchoring strength of amorphous alignment liquid crystal display from capacitance versus applied voltage measurement
被引:0
作者:
Toko, Y
论文数: 0引用数: 0
h-index: 0
机构:Stanley Elect Co Ltd, R&D Lab, Aoba Ku, Yokohama, Kanagawa 2250014, Japan
Toko, Y
Akahane, T
论文数: 0引用数: 0
h-index: 0
机构:Stanley Elect Co Ltd, R&D Lab, Aoba Ku, Yokohama, Kanagawa 2250014, Japan
Akahane, T
机构:
[1] Stanley Elect Co Ltd, R&D Lab, Aoba Ku, Yokohama, Kanagawa 2250014, Japan
[2] Nagaoka Univ Technol, Fac Engn, Dept Elect Engn, Nagaoka, Niigata 9402188, Japan
来源:
MOLECULAR CRYSTALS AND LIQUID CRYSTALS
|
2001年
/
368卷
关键词:
amorphous LCD;
pretilt angle;
polar anchoring strength;
capacitance versus applied voltage characteristics;
liquid crystal;
D O I:
暂无
中图分类号:
O6 [化学];
学科分类号:
0703 ;
摘要:
The pretilt angle and the anchoring strength are important parameters in liquid crystal displays (LCDs). However, in the case of amorphous LCDs (a-LCDs). it is difficult to evaluate these parameters by means of conventional measurement method due to non-uniformity of the LC directors. In this paper. we report the simultaneous evaluation method of the pretilt angle and the polar angle anchoring strength of a-LCDs by fitting the theoretical values based on the elastic continuum theory to the data obtained by the measurement of capacitance versus applied voltage X-V) characteristics. We evaluate the pretilt angle and the polar anchoring strength of a-LCD using the polyimide alignment films. We confirm the pretilt angle and the polar anchoring strength of a-LCD are strongly dependent on surface energy of the polyimide alignment film.