Transjugular intrahepatic portosystemic shunt placement: portal vein puncture guided by 3D/2D image registration of contrast-enhanced multi-detector computed tomography and fluoroscopy

被引:19
作者
Meine, Timo C. [1 ]
Dewald, Cornelia L. A. [1 ]
Becker, L. S. [1 ]
Maehringer-Kunz, Aline [2 ]
Massoumy, Benjamin [3 ]
Maschke, Sabine K. [1 ]
Kirstein, Martha M. [3 ]
Werncke, Thomas [1 ]
Wacker, Frank K. [1 ]
Meyer, Bernhard C. [1 ]
Hinrichs, Jan B. [1 ,4 ]
机构
[1] German Ctr Lung Res DZL, Dept Diagnost & Intervent Radiol, Hannover Med Sch, Hannover, Germany
[2] Johannes Gutenberg Univ Mainz, Dept Diagnost & Intervent Radiol, Med Ctr, Mainz, Germany
[3] Hannover Med Sch, Dept Gastroenterol Hepatol & Endocrinol, Hannover, Germany
[4] Hannover Med Sch, Inst Diagnost & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
Transjugular intrahepatic portosystemic shunt; Image-guided therapy; Venous intervention; Image registration; Operator experience; CONE-BEAM CT; TIPS; COMPLICATIONS; PREVENTION; GUIDANCE; SUCCESS; SOCIETY; TRIAL;
D O I
10.1007/s00261-020-02589-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background To assess the technical feasibility, success rate, puncture complications and procedural characteristics of transjugular intrahepatic portosystemic shunt (TIPS) placement using a three-dimensional vascular map (3D-VM) overlay based on image registration of pre-procedural contrast-enhanced (CE) multi-detector computed tomography (MDCT) for portal vein puncture guidance. Materials and methods Overall, 27 consecutive patients (59 +/- 9 years, 18male) with portal hypertension undergoing elective TIPS procedure were included. TIPS was guided by CE-MDCT overlay after image registration based on fluoroscopic images. A 3D-VM of the hepatic veins and the portal vein was created based on the pre-procedural CE-MDCT and superimposed on fluoroscopy in real-time. Procedural characteristics as well as hepatic vein catheterization time (HVCT), puncture time (PT), overall procedural time (OPT), fluoroscopy time (FT) and the dose area product (DAP) were evaluated. Thereafter, HVCT, PT, OPT and FT using 3D-VM (61 +/- 9 years, 14male) were compared to a previous using classical fluoroscopic guidance (53 +/- 9 years, 21male) for two interventional radiologist with less than 3 years of experience in TIPS placement. Results All TIPS procedure using of 3D/2D image registered 3D-VM were successful with a significant reduction of the PSG (p < 0.0001). No clinical significant complication occurred. HVCT was 14 +/- 11 min, PT was 14 +/- 6 min, OPT was 64 +/- 29 min, FT was 21 +/- 12 min and DAP was 107.48 +/- 93.84 Gy cm(2). HVCT, OPT and FT of the interventionalist with less TIPS experience using 3D/2D image registered 3D-VM were statistically different to an interventionalist with similar experience using fluoroscopic guidance (p(HVCT) = 0.0022; p(OPT) = 0.0097; p(FT) = 0.0009). PT between these interventionalists was not significantly different (p(PT) = 0.2905). Conclusion TIPS placement applying registration-based CE-MDCT vessel information for puncture guidance is feasible and safe. It has the potential to improve hepatic vein catherization, portal vein puncture and radiation exposure.
引用
收藏
页码:3934 / 3943
页数:10
相关论文
共 34 条
[31]   Pros and cons of TIPS for refractory ascites [J].
Sanyal, AJ .
JOURNAL OF HEPATOLOGY, 2005, 43 (06) :924-925
[32]   Radiation Dose in Prostatic Artery Embolization Using Cone-Beam CT and 3D Roadmap Software [J].
Schott, Peter ;
Katoh, Marcus ;
Fischer, Nicolas ;
Freyhardt, Patrick .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 30 (09) :1452-1458
[33]   Three-dimensional Image Fusion Guidance for Transjugular Intrahepatic Portosystemic Shunt Placement [J].
Tacher, Vania ;
Petit, Arthur ;
Derbel, Haytham ;
Novelli, Luigi ;
Vitellius, Manuel ;
Ridouani, Fourat ;
Luciani, Alain ;
Rahmouni, Alain ;
Duvoux, Christophe ;
Salloum, Chady ;
Chiaradia, Mlanie ;
Kobeiter, Hicham .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 40 (11) :1732-1739
[34]   Three-Dimensional Path Planning Software-Assisted Transjugular Intrahepatic Portosystemic Shunt: A Technical Modification [J].
Tsauo, Jiaywei ;
Luo, Xuefeng ;
Ye, Linchao ;
Li, Xiao .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (03) :742-746