A miniaturized electrochemical device integrating a biconical microchannel and carbon fiber disk ultramicroelectrode

被引:7
作者
Chang, Fengxia [1 ]
Xie, Xia [1 ]
Li, Meixian [1 ]
Zhu, Zhiwei [1 ]
机构
[1] Peking Univ, Beijing Natl Lab Mol Sci, Coll Chem & Mol Engn, Beijing 100871, Peoples R China
基金
中国国家自然科学基金;
关键词
URIC-ACID; MICROELECTRODES; ELECTRODE; NANOELECTRODES; FABRICATION; BIOSENSORS; SYSTEM; BEAM;
D O I
10.1039/c6an01205a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, cheap and practicable miniaturized electrochemical device based on a biconical microchannel was developed, for which only 1 mu L sample solution was needed to implement a typical electrochemical experiment. The practicability of the designed device was validated by detecting uric acid as a model molecule in human serum.
引用
收藏
页码:4859 / 4862
页数:4
相关论文
共 24 条
[1]   New trends in electrochemical supercapacitors [J].
Arbizzani, C ;
Mastragostino, M ;
Soavi, F .
JOURNAL OF POWER SOURCES, 2001, 100 (1-2) :164-170
[2]   Electrochemistry in nanovials fabricated by combining screen printing and laser micromachining [J].
Ball, JC ;
Scott, DL ;
Lumpp, JK ;
Daunert, S ;
Wang, J ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :497-501
[3]   A bidirection-adjustable ionic current rectification system based on a biconical micro-channel [J].
Chang, Fengxia ;
Chen, Cheng ;
Xie, Xia ;
Chen, Lisha ;
Li, Meixian ;
Zhu, Zhiwei .
CHEMICAL COMMUNICATIONS, 2015, 51 (83) :15316-15319
[4]  
Christian A., 2008, CHEM REV, V108, P2585
[5]  
DUTT V V S E, 1974, Analytical Chemistry, V46, P1777, DOI 10.1021/ac60348a041
[6]   A mini-electrochemical system integrated micropipet tip and pencil graphite electrode for detection of anticancer drug sensitivity in vitro [J].
Guo, Xiaoling ;
Wang, Qian ;
Li, Jinlian ;
Cui, Jiwen ;
Zhou, Shi ;
Hao, Sue ;
Wu, Dongmei .
BIOSENSORS & BIOELECTRONICS, 2015, 64 :594-596
[7]   A miniaturized electrode system for voltammetric determination of electrochemically reducible environmental pollutants [J].
Hajkova, Andrea ;
Vyskocil, Vlastimil ;
Josypcuk, Bohdan ;
Barek, Jiri .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 227 :263-270
[8]   A method for the fabrication of low-noise carbon fiber nanoelectrodes [J].
Huang, WH ;
Pang, DW ;
Tong, H ;
Wang, ZL ;
Cheng, JK .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1048-1052
[9]   Nitrogen-doped zinc oxide thin films biosensor for determination of uric acid [J].
Jindal, Kajal ;
Tomar, Monika ;
Gupta, Vinay .
ANALYST, 2013, 138 (15) :4353-4362
[10]  
Johnson D. C., 1994, ANAL CHEM, V62, p1R