Identification of FRCM Mechanical Parameters for the Retrofitting Design of Existing Structures

被引:0
|
作者
Rampini, Marco C. [1 ]
Zani, Giulio [1 ]
Colombo, Matteo [1 ]
di Prisco, Marco [1 ]
机构
[1] Politecn Milan, Dept Civil & Environm Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
来源
HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET | 2018年
关键词
Fabric Reinforced Cementitious Matrix; Externally Bonded; Reinforcements; Alkali-resistant glass; Mortar; Retrofitting design;
D O I
10.1007/978-3-319-59471-2_50
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fabric-Reinforced Cementitious Matrix (FRCM) composites are an effective mean to retrofit damaged structures. Their action depends not only on the behavior in tension of the introduced materials, but also on the bond of the composite with the original substrate. A new Italian standard will be soon introduced, thought to allow the designer to compute the effectiveness of cement-based Externally Bonded Reinforcements (EBR) by combining simple uniaxial tensile tests with shear bond tests. An experimental investigation of FRCMs made of an Alkali-Resistant (AR) glass fabric combined with different matrices and dispersed Polyvinyl Alcohol (PVA) or high-carbon steel microfibers is presented. In this regard, relevant design parameters are matrix toughness and mortar thixotropy. Following the characterization at the material and at the interface scales, the design procedures introduced by the standard are discussed and critically evaluated with reference to an alternative basic test based on Double Edge Wedge Splitting (DEWS) principles. Preliminary conclusions concerning the reliability of the proposed approach are finally drawn.
引用
收藏
页码:413 / 421
页数:9
相关论文
共 50 条
  • [1] Design of Additional Dissipative Structures for Seismic Retrofitting of Existing Buildings
    Bergami, Alessandro Vittorio
    APPLIED SCIENCES-BASEL, 2024, 14 (06):
  • [2] Base isolation for seismic retrofitting of existing structures
    Olariu, I
    Olariu, F
    Sarbu, D
    SEISMIC DESIGN PRACTICE INTO THE NEXT CENTURY: RESEARCH AND APPLICATION, 1998, : 417 - 424
  • [3] Identification of mechanical parameters in underground structures
    Procházka, P
    Trcková, J
    COMPUTATIONAL METHODS IN MATERIALS CHARACTERISATION, 2004, 6 : 101 - 110
  • [4] RETROFITTING DESIGN INTO EXISTING ELECTRICAL-ENGINEERING CURRICULA
    MIDDLETON, NT
    COOLEY, WL
    MCCONNELL, RL
    ENGINEERING EXCELLENCE : PEOPLE MAKE THE DIFFERENCE, VOLS 1-3, 1989, : 276 - 278
  • [5] Seismic retrofitting of existing earthen structures using steel plates
    Reyes, Juan C.
    Rincon, Raul
    Yamin, Luis E.
    Correal, Juan F.
    Martinez, Jose G.
    Sandoval, Juan D.
    Gonzalez, Cristian D.
    Angel, Christiam C.
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 230
  • [6] Topology optimization of the fiber-reinforcement retrofitting existing structures
    Bruggi, Matteo
    Taliercio, Alberto
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2013, 50 (01) : 121 - 136
  • [7] HYSTERESIS IDENTIFICATION OF EXISTING STRUCTURES
    TOUSSI, S
    YAO, JTP
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1983, 109 (05): : 1189 - 1202
  • [8] Retrofitting Existing Masonry Structures by Using Seismic Base Isolation System
    Rawa Asaad
    Ammar Kaadan
    Arabian Journal for Science and Engineering, 2024, 49 : 5243 - 5254
  • [9] Retrofitting Existing Masonry Structures by Using Seismic Base Isolation System
    Asaad, Rawa
    Kaadan, Ammar
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (04) : 5243 - 5254
  • [10] A seismic retrofitting method for existing reinforced concrete structures using CFRP
    Kobatake, Y
    ADVANCED COMPOSITE MATERIALS, 1998, 7 (01) : 1 - 22