Evaluation of the genotoxic effects of fixed appliances on oral mucosal cells and the relationship to nickel and chromium concentrations: An in-vivo study

被引:58
作者
Natarajan, Madhumitha [1 ]
Padmanabhan, Sridevi [1 ]
Chitharanjan, Arun [1 ]
Narasimhan, Malathi [2 ]
机构
[1] Sir Ramachandra Med Coll, Fac Dent Sci, Dept Orthodont, Chennai 600116, Tamil Nadu, India
[2] Sir Ramachandra Med Coll, Fac Dent Sci, Dept Oral Pathol, Chennai 600116, Tamil Nadu, India
关键词
ORTHODONTIC APPLIANCES; METAL RELEASE; BUCCAL CELLS; DNA-DAMAGE; MICRONUCLEUS;
D O I
10.1016/j.ajodo.2010.07.027
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The release of metal ions from fixed orthodontic appliances is a source of concern. The aim of this study was to evaluate genotoxic damage in the oral mucosal cells of patients wearing fixed appliance, and the nickel and chromium ion contents in these cells. Methods: Twenty patients undergoing orthodontic treatment formed the experimental group, and 20 untreated subjects comprised the control group. Oral mucosal smears were collected at 2 times: at debonding and 30 days after debonding. The smears were stained with Papanicolaou stain and studied under a light microscope to evaluate the presence of micronuclei. Inductively coupled plasma-mass spectrometry was used to quantify the presence of metal ions. The data were subjected to the Mann-Whitney U test and the Spearman rank correlation test. Results: The mean micronuclei frequency was significantly higher in the treated group than in the control group at debonding; the difference was smaller and not statistically significant 30 days after debonding. The nickel and chromium ion contents in the experimental group were not significantly higher than in the control group. No correlation could be established between micronuclei frequency and metal ion content. Conclusions: Nickel and chromium alloys of orthodontic appliances emit metal ions in sufficient quantities to induce localized genotoxic effects, but these changes revert on removal of the appliances. (Am J Orthod Dentofacial Orthop 2011; 140: 383-8)
引用
收藏
页码:383 / 388
页数:6
相关论文
共 24 条
[1]  
Agaoglu G, 2001, ANGLE ORTHOD, V71, P375
[2]   Evaluation of Papanicolaou stain for studying micronuclei in buccal cells under field conditions [J].
Ayyad, Sohair B. A. ;
Israel, Ebenezer ;
El-Setouhy, Maged ;
Nasr, Ghada Radwan ;
Mohamed, Mostafa K. ;
Loffredo, Christopher A. .
ACTA CYTOLOGICA, 2006, 50 (04) :398-402
[3]   BIODEGRADATION OF ORTHODONTIC APPLIANCES .1. BIODEGRADATION OF NICKEL AND CHROMIUM INVITRO [J].
BARRETT, RD ;
BISHARA, SE ;
QUINN, JK .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1993, 103 (01) :8-14
[4]   Exfoliated buccal mucosa cells as a source of DNA to study oxidative stress [J].
Borthakur, Gayatri ;
Butryee, Chaniphun ;
Stacewicz-Sapuntzakis, Maria ;
Bowen, Phyllis E. .
CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2008, 17 (01) :212-219
[5]  
Burrows D, 1986, Int Dent J, V36, P30
[6]   Cytogenetic biomonitoring of Brazilian workers exposed to pesticides: Micronucleus analysis in buccal epithelial cells of soybean growers [J].
de Bortoli, Giorgia Moura ;
de Azevedo, Mariana Barbieri ;
da Silva, Luciano Basso .
MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2009, 675 (1-2) :1-4
[7]   In vivo study on metal release from fixed orthodontic appliances and DNA damage in oral mucosa cells [J].
Faccioni, F ;
Franceschetti, P ;
Cerpelloni, M ;
Fracasso, ME .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2003, 124 (06) :687-693
[8]   The micronucleus assay in human buccal cells as a tool for biomonitoring DNA damage: The HUMN project perspective on current status and knowledge gaps [J].
Holland, Nina ;
Bolognesi, Claudia ;
Kirsch-Volders, Micheline ;
Bonassi, Stefano ;
Zeiger, Errol ;
Knasmueller, Siegfried ;
Fenech, Michael .
MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH, 2008, 659 (1-2) :93-108
[9]   Corrosion of orthodontic appliances - should we care? [J].
House, Kate ;
Sernetz, Friedrich ;
Dymock, David ;
Sandy, Jonathan R. ;
Ireland, Anthony J. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (04) :584-592
[10]   Metal release from simulated fixed orthodontic appliances [J].
Hwang, CJ ;
Shin, JS ;
Cha, JY .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 120 (04) :383-391