Vertically dispersive holographic screens and autostereoscopic displays in 3D medical imaging

被引:0
作者
Magalhaes, Daniel S. F. [1 ]
Serra, Rolando L. [2 ]
Vannucci, Andre L. [2 ,3 ]
Moreno, Alfredo B. [2 ]
Magalhaes, Lucas V. B. [1 ]
Llovera, Juan J. [2 ]
Li, Li M. [1 ]
机构
[1] Univ Estadual Campinas, Hosp Clin, Lab Neuroimagem, Fac Ciencias Med, 2 Andar,Rua Vital Brasil 251, BR-13083888 Campinas, SP, Brazil
[2] iInst Super Politecn Jose Antonio Echeverria Cuja, Havana 19390, PQ, Cuba
[3] Univ Campinas UNICAMP, Inst Fis Gleb Wataghin, Lab Opt, BR-13083970 Campinas, SP, Brazil
来源
INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS | 2011年 / 8001卷
基金
巴西圣保罗研究基金会;
关键词
holographic screen; autostereoscopic display; three-dimensional medical imaging;
D O I
10.1117/12.894554
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work we describe a setup employed for the recording of vertical dispersive holographic screens that can be used for medical applications. We show how to obtain holographic screens with areas up to 1200 cm(2), focal length of 25 +/- 2 cm and diffraction efficiency of 7.2%. We analyze the technique employed and the holographic screens obtained. Using this screen we describe a setup for the projection of Magnetic Resonance or Tomographic Images. We also describe and present the first results of an autostereoscopic system for 3D medical imaging.
引用
收藏
页数:8
相关论文
共 20 条
  • [1] Autostereoscopic 3D displays
    Dodgson, NA
    [J]. COMPUTER, 2005, 38 (08) : 31 - +
  • [2] FALCAO A, GERASTEREO SOFTWARE
  • [3] HALLDORSSON T, 2002, Patent No. 6412949
  • [4] High image quality 3D displays with polarizer glasses based on active retarder technology
    Jung, Sung-min
    Lee, Young-bok
    Park, Hyung-ju
    Park, Jin-woo
    Lee, Dong-hoon
    Jeong, Woo-nam
    Kim, Jeong-hyun
    Chung, In-Jae
    [J]. STEREOSCOPIC DISPLAYS AND APPLICATIONS XXII, 2011, 7863
  • [5] Precision-guided surgical navigation system using laser guidance and 3D autostereoscopic image overlay
    Liao, Hongen
    Ishihara, Hirotaka
    Tran, Huy Hoang
    Masamune, Ken
    Sakuma, Ichiro
    Dohi, Takeyoshi
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2010, 34 (01) : 46 - 54
  • [6] *LUM 3D, DISPL 3D 22 LUM3D22B
  • [7] 3-DIMENSIONAL PHOTOGRAPHY BY HOLOGRAPHY
    LUNAZZI, JJ
    [J]. OPTICAL ENGINEERING, 1990, 29 (01) : 9 - 14
  • [8] Construction of white-light holographic screens
    Lunazzi, Jose J.
    Magalhaes, Daniel S. F.
    Serra, Rolando L.
    [J]. OPTICAL ENGINEERING, 2009, 48 (09)
  • [9] Holo-television system with a single plane
    Lunazzi, Jose J.
    Magalhaes, Daniel S. E.
    Rivera, Noemi I. R.
    Serra, Rolando L.
    [J]. OPTICS LETTERS, 2009, 34 (04) : 533 - 535
  • [10] Construction of restricted field of view holographic screens
    Magalhaes, Daniel S. F.
    Lunazzi, Jose J.
    Serra, Rolando L.
    [J]. OPTICS AND LASER TECHNOLOGY, 2011, 43 (01) : 119 - 123