Localization of Partial Discharge source in High Voltage apparatus using multiple UHF sensors

被引:0
|
作者
Mishra, D. K. [1 ]
Sarkar, B. [1 ]
Koley, C. [1 ]
Roy, N. K. [1 ]
机构
[1] Natl Inst Technol Durgapur, Dept Elect Engn, Durgapur, W Bengal, India
来源
2015 INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS SUSTAINABLE GROWTH (ICEPE) | 2015年
关键词
High voltage power apparatus; Partial Discharge; UHF sensor; Partial discharge localization; time difference of arrival;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Measurement of Partial Discharge (PD) in High Voltage (HV) power apparatus has become an emerging issue. It helps to provide prior warning before sudden failure of the apparatus. The measurement of PD in HV power apparatus and in any electrical systems helps to reduce the down time including saving of money. For large and complex apparatus apart from PD measurement, it is also mandatory to find out the actual PD location which finally helps to identify the particular point of disorder. As a result of which corrective action can be taken with higher accuracy at lower cost. In this paper multiple UHF sensors has been used to identify and localize the PD source. Calculation has been made with the help of Time Difference of Arrival (TDO) method for on-line PD measurement and localization of the source in the apparatus at the laboratory environment. Experimental results prove the authenticity of the proposed method.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Partial Discharge Source Localization using UHF Sensors
    Gohil, Nidhi J.
    Kundu, Prasanta
    Chowdhury, Anandita
    2017 3RD INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2017, : 208 - 211
  • [2] Partial Discharge Localization in Transformers Using UHF Sensors
    Sinaga, H. H.
    Phung, B. T.
    Ao, P. L.
    Blackburn, T. R.
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 64 - 68
  • [3] Optimal Placement of UHF Sensors for Accurate Localization of Partial Discharge Source in GIS
    Liang, Rui
    Wu, Shenglei
    Chi, Peng
    Peng, Nan
    Li, Yi
    ENERGIES, 2019, 12 (06):
  • [4] Localisation of Partial Discharge source through Delay calculation using UHF sensors
    Anitha, Bhukya
    Mishra, Dipak Kumar
    Koley, Chiranjib
    2017 IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (IEEE WIECON-ECE 2017), 2017, : 172 - 175
  • [5] The Location of Partial Discharge Source in the Power Transformer with UHF Sensors
    Xue, Naifan
    Yang, Junjie
    2018 5TH INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2018, : 261 - 265
  • [6] Partial Discharge Localization in Transformers Using Monopole and Log-Spiral UHF Sensors
    Sinaga, H. H.
    Phung, B. T.
    Blackburn, T. R.
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [7] Partial Discharge Detection and Localization of Defected Power Cable Using HFCT and UHF Sensors
    Singsathien, J.
    Suwanasri, T.
    Suwanasri, C.
    Ruankon, S.
    Fuangpian, P.
    Namvong, W.
    Saengsaikaew, P.
    Khotsang, W.
    2017 14TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2017, : 505 - 508
  • [8] Detection of partial discharge in the high voltage apparatus
    Zheng, DC
    Zhang, CX
    Chen, CT
    Yu, CS
    Yang, JX
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 323 - 326
  • [9] MULTIPLE PARTIAL DISCHARGE SOURCE DISCRIMINATION IN A HIGH VOLTAGE TRANSFORMER WINDING
    Ali, N. H. Nik
    Rapisarda, P.
    Lewin, P. L.
    2017 INSUCON - 13TH INTERNATIONAL ELECTRICAL INSULATION CONFERENCE (INSUCON), 2017,
  • [10] Study on localization of transformer partial discharge source with planar arrangement UHF sensors based on singular value elimination
    Zhang, Guozhi
    Zhang, Xiaoxing
    Tang, Ju
    Cheng, Hongtu
    AIP ADVANCES, 2018, 8 (10)