Numerical analysis of the axially loaded concrete filled steel tube columns with debonding separation at the steel-concrete interface

被引:0
作者
Chen Shiming [1 ]
Zhang Huifeng [1 ,2 ]
机构
[1] Tongji Univ, Sch Civil Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, Architectural Design & Res Inst, Shanghai 200092, Peoples R China
基金
美国国家科学基金会;
关键词
debonding separation; concrete filled steel tube; axial compression; load carrying capacity; STUB COLUMNS; NONLINEAR-ANALYSIS; COMPRESSION; STRENGTH; BEHAVIOR;
D O I
10.12989/scs.2012.13.3.277
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The interaction between steel tube and concrete core is the key design considerations for concrete-filled steel tube columns. In a concrete-filled steel tube (CFST) column, the steel tube provides confinement to the concrete core which permits the composite action among the steel tube and the concrete. Due to construction faults and plastic shrinkage of concrete, the debonding separation at the steel-concrete interface weakens the confinement effect, and hence affects the behaviour and bearing capacity of the composite member. This study investigates the axial loading behavior of the concrete filled circular steel tube columns with debonding separation. A three-dimensional nonlinear finite element model of CFST composite columns with introduced debonding gap was developed. The results from the finite element analysis captured successfully the experimental behaviours. The calibrated finite element models were then utilized to assess the influence of concrete strength, steel yield stress and the steel-concrete ratio on the debonding behaviour. The findings indicate a likely significant drop in the load carrying capacity with the increase of the size of the debonding gap. A design formula is proposed to reduce the load carrying capacity with the presence of debonding separation.
引用
收藏
页码:277 / 293
页数:17
相关论文
共 26 条
[1]  
AIJ, 1997, Recommendations for Design and Construction of Concrete Filled Steel Tubular Structures
[2]  
American Concrete Institute (ACI), 2011, Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary, 318R-11
[3]  
[Anonymous], 2010, SPEC STRUCT STEEL BU
[4]  
Bahrami A, 2011, STRUCT ENG MECH, V39, P383
[5]   Analytical Studies of Concrete-Filled Circular Steel Tubes under Axial Compression [J].
Choi, K. K. ;
Xiao, Y. .
JOURNAL OF STRUCTURAL ENGINEERING, 2010, 136 (05) :565-573
[6]   Behaviour of normal and high strength concrete-filled compact steel tube circular stub columns [J].
Ellobody, Ehab ;
Young, Ben ;
Lam, Dennis .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (07) :706-715
[7]  
Eurocode 4 (EC4), 2004, 1994112004 EC4 EN EU
[8]   Experimental and computational study of concrete filled steel tubular columns under axial loads [J].
Gupta, P. K. ;
Sarda, S. M. ;
Kumar, M. S. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (02) :182-193
[9]  
Hajjar J.F., 2003, PROGR STRUCTURAL ENG, V3, P72
[10]  
Han L.H., 2011, P 2011 WORLD C ADV S