Temperature variation at the external root surface during 980-nm diode laser irradiation in the root canal

被引:56
作者
Alfredo, E. [1 ]
Marchesan, M. A. [1 ]
Sousa-Neto, M. D. [2 ]
Brugnera-Junior, A. [1 ]
Silva-Sousa, Y. T. C. [1 ]
机构
[1] Univ Ribeirao Preto, Sch Dent, Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Sch Dent, Dept Restorat Dent, BR-14049 Ribeirao Preto, SP, Brazil
关键词
diode laser; temperature increase; intrapulpar irradiation; endodontics;
D O I
10.1016/j.jdent.2008.03.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To assess the temperature variation in the cervical, middle and apical thirds of root external wall, caused by 980-nm diode laser irradiation with different parameters. Methods: The roots of 90 canines, had their canals instrumented and were randomly distributed into 3 groups (n = 30) according to the laser potency (1.5 W, 3.0 W and 5.0 W). Each group was subdivided into 3 (n = 10) according to the frequency (CM, 100 Hz and 1000 Hz), and each subgroup divided into 2 (n = S): dried canal or filled with distilled water. The maximum temperature values were collected by 3 thermocouples located at each third of the root external wall and recorded by digital thermometers. Results: The groups irradiated in the continuous mode (CM) presented the highest values (11.82 +/- 5.78), regardless of the canals were dry or not, which were statistically different (p < 0.01) from those obtained with 100 Hz (6.22 +/- 3.64) and 1000 Hz (6.00 +/- 3.36), which presented no statistical difference between them (p > 0.01). The groups irradiated with 5.0 W presented the greatest temperature variation (12.15 +/- 5.14), followed by 3.0 W (7.88 +/- 3.92) and 1.5 W (4.02 +/- 2.16), differing between them (p < 0.01). The cervical third of the root presented the highest temperature rises (9.68 +/- 5.80), followed by the middle (7.66 +/- 4.87) and apical (6.70 +/- 4.23), with statistical difference among them (p < 0.01). After 30 s from the end of irradiation, all the specimens presented temperature variation lower than 10 degrees C. Conclusions: Application of 980-nm diode laser in the root, at 1.5 W in all operating modes, and 3.0 W, in the pulsed mode, for 20 s, can safely be used in endodontic treatment, irrespective of the presence of humidity. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:529 / 534
页数:6
相关论文
共 26 条
[1]  
Alves PRV, 2005, PHOTOMED LASER SURG, V23, P410
[2]   Scanning electron microscopic study of dentin lased with argon, CO2, and Nd:YAG laser [J].
Anic, I ;
Segovic, S ;
Katanec, D ;
Prskalo, K ;
Najzar-Fleger, D .
JOURNAL OF ENDODONTICS, 1998, 24 (02) :77-81
[3]  
BAHCALL J, 1992, J ENDODONT, V18, P123
[4]  
Barbizam JVB, 2002, J ENDODONT, V28, P365
[5]   Penetration ability of different irrigants into dentinal tubules [J].
Berutti, E ;
Marini, R ;
Angeretti, A .
JOURNAL OF ENDODONTICS, 1997, 23 (12) :725-727
[6]  
Bornstein Eric, 2004, Dent Today, V23, P102
[7]   Histological evaluation of the use of diode laser as an adjunct to traditional periodontal treatment [J].
Castro, GL ;
Gallas, M ;
Núñez, IR ;
Borrajo, JLL ;
Varela, LG .
PHOTOMEDICINE AND LASER SURGERY, 2006, 24 (01) :64-68
[8]  
COLUZZI DJ, 2004, DENTISTRY TODAY, V1, P120
[9]  
De Moor Roeland, 2005, Rev Belge Med Dent (1984), V60, P115
[10]   THERMAL-INJURY TO BONE - A VITAL-MICROSCOPIC DESCRIPTION OF HEAT-EFFECTS [J].
ERIKSSON, A ;
ALBREKTSSON, T ;
GRANE, B ;
MCQUEEN, D .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1982, 11 (02) :115-121