Exploring the role of vacancy defects in the optical properties of LiMgPO4

被引:40
作者
Modak, Pampa [1 ,2 ]
Modak, Brindaban [2 ,3 ]
机构
[1] Atom Energy Regulatory Board, RSD, Mumbai 400094, Maharashtra, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, Maharashtra, India
[3] Bhabha Atom Res Ctr, Theoret Chem Sect, Mumbai 400085, Maharashtra, India
关键词
LITHIUM MAGNESIUM PHOSPHATE; GENERALIZED GRADIENT APPROXIMATION; STIMULATED LUMINESCENCE; OSL KINETICS; THERMOLUMINESCENCE; PHOTOLUMINESCENCE; TEMPERATURE; EXCHANGE; PHASE; TL;
D O I
10.1039/d0cp02425b
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Linearity in dose response up to very high radiation doses and sufficient sensitivity to even low radiation doses are extremely important for the measurement of radiation dose in the field of radiation technology, ranging from medical to industrial applications. Olivine type LiMgPO(4)has been shown immense interest as a phosphor material in the fields of thermoluminescence and optically stimulated luminescence dosimetry. In the present study, we have explored the role of different vacancy defects in the optical properties of LiMgPO(4)aiming at enhancing its sensitivity for the measurement of radiation dose. For this purpose, we have systematically investigated the electronic structure of LiMgPO(4)in the absence and presence of various vacancy defects using density functional theory as a tool. The present study considers all possible vacancy defects including neutral, charged and mixed lattice vacancy defects in LiMgPO4. To find the most energetically favourable vacancy defect, we have compared the defect formation energy of all the vacancy defects. We have also calculated vacancy formation energy in different chemical environments to investigate how the formation of different types of vacancy defect can be controlled by tuning the chemical environment. Finally, the origin of the different optical properties of LiMgPO(4)has been explained by using a possible mechanism based on our detailed electronic structure calculations. Thus, the present study is believed to provide valuable insight for the development of materials with improved features for the measurement of radiation dose.
引用
收藏
页码:16244 / 16257
页数:14
相关论文
共 69 条
  • [1] Toward reliable density functional methods without adjustable parameters: The PBE0 model
    Adamo, C
    Barone, V
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1999, 110 (13) : 6158 - 6170
  • [2] Spin-orbit coupling in quasiparticle studies of topological insulators
    Aguilera, Irene
    Friedrich, Christoph
    Bluegel, Stefan
    [J]. PHYSICAL REVIEW B, 2013, 88 (16)
  • [3] Alar E., 2017, RADIAT MEAS, V103, P13
  • [4] Luminescence properties of different Eu sites in LiMgPO4:Eu2+, Eu3+
    Baran, A.
    Mahlik, S.
    Grinberg, M.
    Cai, P.
    Kim, S. I.
    Seo, H. J.
    [J]. JOURNAL OF PHYSICS-CONDENSED MATTER, 2014, 26 (38)
  • [5] PROJECTOR AUGMENTED-WAVE METHOD
    BLOCHL, PE
    [J]. PHYSICAL REVIEW B, 1994, 50 (24): : 17953 - 17979
  • [6] High sensitivity thermoluminescence dosimetry
    Bos, AJJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 184 (1-2) : 3 - 28
  • [7] Consistent treatment of charged systems within periodic boundary conditions: The projector augmented-wave and pseudopotential methods revisited
    Bruneval, Fabien
    Crocombette, Jean-Paul
    Gonze, Xavier
    Dorado, Boris
    Torrent, Marc
    Jollet, Francois
    [J]. PHYSICAL REVIEW B, 2014, 89 (04)
  • [8] The use of different types of thermoluminescent dosimeters to measure extremity doses in nuclear medicine
    Carnicer, A.
    Ginjaume, M.
    Duch, M. A.
    Vanhavere, F.
    Merce, M. Sans
    Baechler, S.
    Barth, I.
    Donadille, L.
    Ferrari, P.
    Fulop, M.
    Gualdrini, G.
    Krim, S.
    Mariotti, M.
    Ortega, X.
    Rimpler, A.
    Ruiz, N.
    Olko, P.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1835 - 1838
  • [9] Chandra B., 1982, Radiation Protection Dosimetry, V3, P161
  • [10] e-Abbas S. M. A., 2017, SCI REP, V7, P8439