Potentiometric determination of antihistaminic diphenhydramine hydrochloride in pharmaceutical preparations and biological fluids using screen-printed electrode

被引:41
作者
Frag, Eman Y. Z. [1 ]
Mohamed, Gehad G. [1 ]
El-Sayed, Wael G. [1 ]
机构
[1] Cairo Univ, Fac Sci, Dept Chem, Giza 12613, Egypt
关键词
Screen-printed electrode; Potentiometric titration; Pharmaceutical preparations; Diphenhydramine hydrochloride; Biological fluids; ION-SELECTIVE ELECTRODES; MEMBRANE SENSOR; QUANTITATIVE HPTLC; CHLORIDE; URINE; DRUGS; SPECTROPHOTOMETRY; FORMULATIONS; SILDENAFIL; INJECTION;
D O I
10.1016/j.bioelechem.2011.05.006
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The performance characteristic of sensitive screen-printed (SPE) and carbon paste (CPE) electrodes was investigated for the determination of diphenhydramine hydrochloride (DPH) drug in pure, pharmaceutical preparations and biological fluids. Different experimental conditions namely types of materials used to prepare the working electrode (plasticizer), titrant, pH, temperature and life time were studied. Under these conditions, the SPE shows the best performance than CPE with respect to total potential change and potential break at the end point. The SPE and CPE exhibit suitable response to DPH in a concentration range of 1.0.10(-2) to 1.0.10(-6) mol/L with a limit of detection 9.70.10(-7) and 9.80.10(-7) mol/L, respectively. The slope of the system was 55.2 +/- 1.0 and 54.7 +/- 1.0 mV/decade over pH range 3.0-8.0 and 3-7 for SPE and CPE, respectively. Selectivity coefficients for DPH relative to a numbers of potential interfering substances were investigated. The SPE and CPE show a fast response time of 10 and 16s and were used over a period of 2 months with a good reproducibility. The sensors were applied successfully to determine DPH in pharmaceutical preparations and biological fluids. The results are compared with the official method. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 44 条
[1]  
[Anonymous], 1970, PHARM US
[2]  
[Anonymous], 1985, US PHARM, P340
[3]  
[Anonymous], 2000, US PHARM, P583
[4]  
Antropov L, 1977, THEORETICAL ELECTROC
[5]   Determination of isoniazid in human urine using screen-printed carbon electrode modified with poly-L-histidine [J].
Bergamini, Marcio F. ;
Santos, Daniela P. ;
Zanoni, Maria Valnice B. .
BIOELECTROCHEMISTRY, 2010, 77 (02) :133-138
[6]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[7]  
Cosofret V.V., 1992, PHARM APP MEMBRANE S
[8]   ASSAY OF BENZENOID DRUGS IN TABLET AND CAPSULE FORMULATIONS BY 2ND-DERIVATIVE ULTRAVIOLET SPECTROPHOTOMETRY [J].
DAVIDSON, AG ;
HASSAN, SM .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (03) :413-416
[9]   Determination of the sleep aid ingredients diphenhydramine hydro chloride and doxylamine succinate in pharmaceutical products by quantitative HPTLC [J].
DiGregorio, D ;
Sherma, J .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (10) :1599-1606
[10]   Ion-selective electrodes for determination of organic ammonium ions: Ways for selectivity control [J].
Egorov, Vladimir V. ;
Bolotin, Alexander A. .
TALANTA, 2006, 70 (05) :1107-1116