Rapid Verification of Candidate Serological Biomarkers Using Gel-based, Label-free Multiple Reaction Monitoring

被引:28
作者
Tang, Hsin-Yao [1 ,2 ]
Beer, Lynn A. [1 ,2 ]
Barnhart, Kurt T. [3 ,4 ]
Speicher, David W. [1 ,2 ]
机构
[1] Wistar Inst Anat & Biol, Ctr Syst & Computat Biol, Philadelphia, PA 19104 USA
[2] Wistar Inst Anat & Biol, Mol & Cellular Oncogenesis Program, Philadelphia, PA 19104 USA
[3] Univ Penn, Sch Med, Dept Obstet & Gynecol, Philadelphia, PA 19104 USA
[4] Univ Penn, Sch Med, Ctr Clin Epidemiol & Biostat, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
serum proteomes; serum biomarkers; biomarker verification; biomarker validation; label-free quantitation; multiple reaction monitoring (MRM); MASS-SPECTROMETRIC QUANTIFICATION; ABSOLUTE QUANTIFICATION; CATHEPSIN-D; ISOTOPE-DILUTION; QUANTITATIVE PROTEOMICS; PLASMA-PROTEINS; SERUM MARKER; CANCER; DISCOVERY; PEPTIDES;
D O I
10.1021/pr2002098
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Stable isotope dilution-multiple reaction monitoring-mass spectrometry (SID-MRM-MS) has emerged as a promising platform for verification of serological candidate biomarkers. However, cost and time needed to synthesize and evaluate stable isotope peptides, optimize spike-in assays, and generate standard curves quickly becomes unattractive when testing many candidate biomarkers. In this study, we demonstrate that label-free multiplexed MRM-MS coupled with major protein depletion and 1D gel separation is a time-efficient, cost-effective initial biomarker verification strategy requiring less than 100 mu L of serum. Furthermore, SDS gel fractionation can resolve different molecular weight forms of targeted proteins with potential diagnostic value. Because fractionation is at the protein level, consistency of peptide quantitation profiles across fractions permits rapid detection of quantitation problems for specific peptides from a given protein. Despite the lack of internal standards, the entire workflow can be highly reproducible, and long-term reproducibility of relative protein abundance can be obtained using different mass spectrometers and LC methods with external reference standards. Quantitation down to similar to 200 pg/mL could be achieved using this workflow. Hence, the label-free GeLC-MRM workflow enables rapid, sensitive, and economical initial screening of large numbers of candidate biomarkers prior to setting up SID-MRM assays or immunoassays for the most promising candidate biomarkers.
引用
收藏
页码:4005 / 4017
页数:13
相关论文
共 50 条
[1]   Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma [J].
Addona, Terri A. ;
Abbatiello, Susan E. ;
Schilling, Birgit ;
Skates, Steven J. ;
Mani, D. R. ;
Bunk, David M. ;
Spiegelman, Clifford H. ;
Zimmerman, Lisa J. ;
Ham, Amy-Joan L. ;
Keshishian, Hasmik ;
Hall, Steven C. ;
Allen, Simon ;
Blackman, Ronald K. ;
Borchers, Christoph H. ;
Buck, Charles ;
Cardasis, Helene L. ;
Cusack, Michael P. ;
Dodder, Nathan G. ;
Gibson, Bradford W. ;
Held, Jason M. ;
Hiltke, Tara ;
Jackson, Angela ;
Johansen, Eric B. ;
Kinsinger, Christopher R. ;
Li, Jing ;
Mesri, Mehdi ;
Neubert, Thomas A. ;
Niles, Richard K. ;
Pulsipher, Trenton C. ;
Ransohoff, David ;
Rodriguez, Henry ;
Rudnick, Paul A. ;
Smith, Derek ;
Tabb, David L. ;
Tegeler, Tony J. ;
Variyath, Asokan M. ;
Vega-Montoto, Lorenzo J. ;
Wahlander, Asa ;
Waldemarson, Sofia ;
Wang, Mu ;
Whiteaker, Jeffrey R. ;
Zhao, Lei ;
Anderson, N. Leigh ;
Fisher, Susan J. ;
Liebler, Daniel C. ;
Paulovich, Amanda G. ;
Regnier, Fred E. ;
Tempst, Paul ;
Carr, Steven A. .
NATURE BIOTECHNOLOGY, 2009, 27 (07) :633-U85
[2]   Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins [J].
Anderson, L ;
Hunter, CL .
MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (04) :573-588
[3]   Candidate-based proteomics in the search for biomarkers of cardiovascular disease [J].
Anderson, L .
JOURNAL OF PHYSIOLOGY-LONDON, 2005, 563 (01) :23-60
[4]   The Clinical Plasma Proteome: A Survey of Clinical Assays for Proteins in Plasma and Serum [J].
Anderson, N. Leigh .
CLINICAL CHEMISTRY, 2010, 56 (02) :177-185
[5]   The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[6]   Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-MS/MS using protein cleavage and isotope dilution mass spectrometry [J].
Barnidge, DR ;
Goodmanson, MK ;
Klee, GG ;
Muddiman, DC .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (03) :644-652
[7]   Absolute quantification of the G protein-coupled receptor rhodopsin by LC/MS/MS using proteolysis product peptides and synthetic peptide standards [J].
Barnidge, DR ;
Dratz, EA ;
Martin, T ;
Bonilla, LE ;
Moran, LB ;
Lindall, A .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :445-451
[8]  
Barr JR, 1996, CLIN CHEM, V42, P1676
[9]   Systematic Discovery of Ectopic Pregnancy Serum Biomarkers Using 3-D Protein Profiling Coupled with Label-free Quantitation [J].
Beer, Lynn A. ;
Tang, Hsin-Yao ;
Sriswasdi, Sira ;
Barnhart, Kurt T. ;
Speicher, David W. .
JOURNAL OF PROTEOME RESEARCH, 2011, 10 (03) :1126-1138
[10]   Cathepsin D-Many functions of one aspartic protease [J].
Benes, Petr ;
Vetvicka, Vaclav ;
Fusek, Martin .
CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2008, 68 (01) :12-28