Quasi-telecentric optical design of a microscope-compatible OCT scanner

被引:29
作者
Hu, ZL [1 ]
Rollins, AM [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn & Med, Cleveland, OH 44106 USA
来源
OPTICS EXPRESS | 2005年 / 13卷 / 17期
关键词
D O I
10.1364/OPEX.13.006407
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report an optical coherence tomography (OCT) scanner design with optimized quasi-telecentric optics. This scanner achieves a uniform, Gaussian spot size of 15 mu M (1/e(2) diameter) over a range of 4.4mm in two orthogonal transverse scan dimensions. Model simulation using optical design software agrees with measurements by beam analyzer. We provide a reasonable design criterion of 0.05 ( the ratio of the half separation of two orthogonal scanning mirrors to the front focal length of the optics that follow) for the quasi-telecentric scanner which corresponds to a spot-size and spot ellipticity variation of only 4% over the transverse scan range. Furthermore, this OCT scanner accommodates a microscope to precisely guide and document OCT imaging of small samples. OCT images of in-vivo human skin, human nail fold, and embryonic hearts (avian stage 22 and stage 28) demonstrate the image quality achieved with the scanner. The results indicate that optimizing the sample scanner optical design is important for optimizing OCT image quality. (c) 2005 Optical Society of America.
引用
收藏
页码:6407 / 6415
页数:9
相关论文
共 28 条
  • [1] High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography
    Bouma, BE
    Tearney, GJ
    Compton, CC
    Nishioka, NS
    [J]. GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) : 467 - 474
  • [2] Construction of a confocal microscope for real-time x-y and x-z imaging
    Callamaras, N
    Parker, I
    [J]. CELL CALCIUM, 1999, 26 (06) : 271 - 279
  • [3] Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    Choma, MA
    Sarunic, MV
    Yang, CH
    Izatt, JA
    [J]. OPTICS EXPRESS, 2003, 11 (18): : 2183 - 2189
  • [4] FELDCHTEIN FI, 2002, HDB OPTICAL COHERENC
  • [5] MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY
    FERCHER, AF
    HITZENBERGER, CK
    KAMP, G
    ELZAIAT, SY
    [J]. OPTICS COMMUNICATIONS, 1995, 117 (1-2) : 43 - 48
  • [6] Study of the beam path distortion profiles generated by a two-axis tilt single-mirror baser scanner
    Hafez, M
    Sidler, T
    Salathé, RP
    [J]. OPTICAL ENGINEERING, 2003, 42 (04) : 1048 - 1057
  • [7] Three-dimensional imaging of the human retina by high-speed optical coherence tomography
    Hitzenberger, CK
    Trost, P
    Lo, PW
    Zhou, QY
    [J]. OPTICS EXPRESS, 2003, 11 (21): : 2753 - 2761
  • [8] An optical coherence microscope for 3-dimensional imaging in developmental biology
    Hoeling, BM
    Fernandez, AD
    Haskell, RC
    Huang, E
    Myers, WR
    Petersen, DC
    Ungersma, SE
    Wang, RY
    Williams, ME
    Fraser, SE
    [J]. OPTICS EXPRESS, 2000, 6 (07): : 136 - 146
  • [9] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [10] Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound
    Jang, IK
    Bouma, BE
    Kang, DH
    Park, SJ
    Park, SW
    Seung, KB
    Choi, KB
    Shishkov, M
    Schlendorf, K
    Pomerantsev, E
    Houser, SL
    Aretz, HT
    Tearney, GJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (04) : 604 - 609