Deriving blood-oxygen-level-dependent contrast in MRI with T2*-weighted, T2-prepared and phase-cycled SSFP methods:: Theory and experiment

被引:15
作者
Arumana, Jain Mangalathu [1 ]
Li, Debiao [1 ,2 ]
Dharmakumar, Rohan [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
SSFP; ischemia; blood; oxygen; BOLD; fMRI;
D O I
10.1002/mrm.21511
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objectives of this work were: 1) to perform a comparative evaluation of the oxygen-sensitive contrast ((OC) over bar) derived from the phase-cycled steady-state free precession (SSFPPC) method against T-2*-weighted gradient recalled echo (GRE) and T-2-prepared (T-2-prep) methods with theoretical simulations and imaging studies using an ischemic leg cuff model at 1.5T and 3.0T; and 2) to investigate the dependence of SSFPPC-based (OC) over bar on imaging parameters. Results showed that the SSFPPC method (repetition time (TR) = 6.3 ms; flip angle (alpha) = 90 degrees) provides significantly higher (OC) over bar compared to T-2-prep (at both field strengths) and GRE (3.0T) (P < 0.05). The <(OC)over bar> of low TR SSFP (TR = 3.5 ms at 1.5T; TR = 4.5 ms at 3.0T; alpha = 90 degrees) was significantly lower compared to GRE [P < 0.05) at 1.5T and 3.0T and to T-2-prep methods at 1.5T [P < 0.05). In summary, the findings from this study are the following: 1) SSFP-based M is directly dependent on TR and a at 1.5T and 3.0T; and 2) (OC) over bar derived with SSFPPC can be increased above GRE and T2-prep methods with an appropriate choice of imaging parameters.
引用
收藏
页码:561 / 570
页数:10
相关论文
共 43 条
[1]   Analysis of multiple-acquisition SSFP [J].
Bangerter, NK ;
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Gold, GE ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) :1038-1047
[2]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[3]   Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency [J].
Deshpande, VS ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :803-809
[4]   Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation [J].
Deshpande, VS ;
Chung, YC ;
Zhang, Q ;
Shea, SM ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :151-157
[5]   Oxygen-sensitive contrast in blood for steady-state free precession imaging [J].
Dharmakumar, R ;
Hong, JM ;
Brittain, JH ;
Plewes, DB ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :574-583
[6]   Cardiac phase-resolved blood oxygen-sensitive steady-state free precession MRI for evaluating the functional significance of coronary artery stenosis [J].
Dharmakumar, Rohan ;
Arumana, Jain Mangalathu ;
Larson, Andrew C. ;
Chung, Yiucho ;
Wright, Graham A. ;
Li, Debiao .
INVESTIGATIVE RADIOLOGY, 2007, 42 (03) :180-188
[7]   Detecting microcirculatory changes in blood oxygen state with steady-state free precession imaging [J].
Dharmakumar, Rohan ;
Qi, Xiuling ;
Hong, Juimiin ;
Wright, Graham A. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1372-1380
[8]   Influence of vascular filling and perfusion on BOLD contrast during reactive hyperemia in human skeletal muscle [J].
Duteil, S ;
Wary, C ;
Raynaud, JS ;
Lebon, V ;
Lesage, D ;
Leroy-Willig, A ;
Carlier, PG .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) :450-454
[9]   Myocardial perfusion Imaging based on the blood oxygen level-dependent effect using T2-prepared steady-state free-precession magnetic resonance Imaging [J].
Fieno, DS ;
Shea, SM ;
Li, YZ ;
Harris, KR ;
Finn, JP ;
Li, DB .
CIRCULATION, 2004, 110 (10) :1284-1290
[10]   Optimized spiral imaging for measurement of myocardial T2 relaxation [J].
Foltz, WD ;
Al-Kwifi, O ;
Sussman, MS ;
Stainsby, JA ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) :1089-1097