Imaging of Diabetic Retinopathy and Diabetic Macular Edema

被引:2
作者
Danis, Ronald P. [1 ]
Hubbard, Larry D. [1 ]
机构
[1] Univ Wisconsin, Fundus Photograph Reading Ctr, Madison, WI 53717 USA
关键词
Diabetic retinopathy severity; Diabetic macular edema; Optical coherence tomography; Fundus photography; Fluorescein angiography; Scanning laser ophthalmoscopy; Photoreceptor outer segments; Clinical trials; Digital imaging; Image quality; ETDRS; OPTICAL COHERENCE TOMOGRAPHY; RETINAL THICKNESS MEASUREMENTS; VISUAL-ACUITY; SEVERITY; LASER; ASSOCIATION; ANGIOGRAPHY; EYES;
D O I
10.1007/s11892-011-0203-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Imaging of the retinal complications of diabetes mellitus is rapidly changing from the emergence of new technology such as optical coherence tomography. In particular, the characterization of diabetic macular edema is much easier for the clinician and there are new, more sensitive clinical research end points. However, our understanding of structure-functional relationships remains suboptimal and the classification of macular edema by optical coherence tomography continues to evolve. The classification of diabetic retinopathy severity continues to rely upon fundus photography, although the transition from film to digital photography presents both challenges and advantages.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 38 条
  • [21] HUBBARD LD, 2011, ARCH OPHTHA IN PRESS
  • [22] Kaines Andrew, 2009, Int Ophthalmol Clin, V49, P53, DOI 10.1097/IIO.0b013e31819fd471
  • [23] Central visual field impairment during and following cystoid macular oedema
    Kiss, C. G.
    Barisani-Asenbauer, T.
    Simader, C.
    Maca, S.
    Schmidt-Erfurth, U.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (01) : 84 - 88
  • [24] RETINAL THICKNESS AND VOLUME MEASUREMENTS IN DIABETIC MACULAR EDEMA A Comparison of Four Optical Coherence Tomography Systems
    Lammer, Jan
    Scholda, Christoph
    Pruente, Christian
    Benesch, Thomas
    Schmidt-Erfurth, Ursula
    Bolz, Matthias
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (01): : 48 - 55
  • [25] Comparison of Multiple Stereoscopic and Monoscopic Digital Image Formats to Film for Diabetic Macular Edema Evaluation
    Li, Helen K.
    Hubbard, Larry D.
    Danis, Ronald P.
    Florez-Arango, Jose F.
    Esquivel, Adol
    Krupinski, Elizabeth A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6753 - 6761
  • [26] GRADING DIABETIC RETINOPATHY SEVERITY FROM COMPRESSED DIGITAL RETINAL IMAGES COMPARED WITH UNCOMPRESSED IMAGES AND FILM
    Li, Helen K.
    Florez-Arango, Jose F.
    Hubbard, Larry D.
    Esquivel, Adol
    Danis, Ronald P.
    Krupinski, Elizabeth A.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (10): : 1651 - 1661
  • [27] Monoscopic versus Stereoscopic Retinal Photography for Grading Diabetic Retinopathy Severity
    Li, Helen K.
    Hubbard, Larry D.
    Danis, Ronald P.
    Esquivel, Adol
    Florez-Arango, Jose F.
    Krupinski, Elizabeth A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (06) : 3184 - 3192
  • [28] The Association Between Percent Disruption of the Photoreceptor Inner Segment-Outer Segment Junction and Visual Acuity in Diabetic Macular Edema
    Maheshwary, Anjali S.
    Oster, Stephen F.
    Yuson, Ritchie M. S.
    Cheng, Lingyun
    Mojana, Francesca
    Freeman, William R.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (01) : 63 - 67
  • [29] Optical coherence tomography for evaluating diabetic macular edema before and after Vitrectomy
    Massin, P
    Duguid, G
    Erginay, A
    Haouchine, B
    Gaudric, A
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (02) : 169 - 177
  • [30] Errors in retinal thickness measurements obtained by optical coherence tomography
    Sadda, SR
    Wu, ZQ
    Walsh, AC
    Richine, L
    Dougall, J
    Cortez, R
    LaBree, LD
    [J]. OPHTHALMOLOGY, 2006, 113 (02) : 285 - 293