A novel method for electroretinogram assessment in patients with central retinal vein occlusion

被引:7
作者
Sefandarmaz, Neda [1 ]
Behbahani, Soroor [2 ]
Ramezani, Alireza [3 ]
机构
[1] Islamic Azad Univ, Dept Biomed Engn, South Tehran Branch, Tehran, Iran
[2] Islamic Azad Univ, Dept Elect Engn, Garmsar Branch, Garmsar, Iran
[3] Shahid Beheshti Univ Med Sci, Ophthalm Epidemiol Res Ctr, Tehran, Iran
关键词
Central retinal vein occlusion; Electroretinogram; Feature extraction; Parabolic mapping; WAVE IMPLICIT TIME; ISCEV STANDARD; CLASSIFICATION; SEIZURE; SIGNALS; RATIO; ERG; EEG;
D O I
10.1007/s10633-019-09742-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Central retinal vein occlusion (CRVO) is the second most common retinal vascular disorder after diabetic retinopathy that affects the eyes. We propose a method for distinction of normal and central CRVO eyes based on electroretinogram (ERG). Methods Seventeen patients with CRVO in one eye were analyzed. Their ERG signals were collected in six different stimuli, including four records in the darkness (dark-adapted 0.01, dark-adapted 3.0, dark-adapted oscillatory potentials, and dark-adapted 10) and two records in brightness (light-adapted 3.0 and light-adapted 30 Hz flicker). Nonlinear features such as Hurst exponent (HE) and approximate entropy (ApEn) were extracted from healthy and CRVO eyes. Finally, a parabolic mapping and two criteria (theta angle and the density of points) were proposed to distinguish the groups. Results For ApEn, the P values of dark-adapted 3.0 oscillatory (P = 0.0433) and flicker (P = 0.0425) confirmed significant differences between the groups. For HE, the P values of dark-adapted 3.0 oscillatory (P = 0.0421) and flicker 30 Hz (P = 0.0402) confirmed differences between the healthy and CRVO groups. The P values of theta angle for dark-adapted 3.0 (P = 0.0199), dark-adapted oscillatory (P = 0.0265), dark-adapted 10.0 (P = 0.0166), light-adapted 3.0 (P = 0.0411), and flicker (P = 0.0361) showed significant differences. Using the density criterion, the statistical test demonstrated a significant difference between the groups in dark-adapted 3 (P = 0.0038), dark-adapted oscillatory (P = 0.0102), dark-adapted 10.0 (P = 0.0071), light-adapted 3.0 (P = 0.0319), and flicker 30 Hz (P = 0.0076). Conclusion The proposed features have made it possible to distinguish between healthy and CRVO eyes. This method could be helpful in some cases with no definite diagnosis or to estimate the severity of CRVO.
引用
收藏
页码:257 / 271
页数:15
相关论文
共 43 条
[1]   A wavelet-chaos methodology for analysis of EEGs and EEG subbands to detect seizure and epilepsy [J].
Adeli, Hojjat ;
Ghosh-Dastidar, Samanwoy ;
Dadmehr, Nahid .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (02) :205-211
[2]  
[Anonymous], J BIOMEDICAL SCI ENG
[3]  
[Anonymous], INVESTIG OPHTHALMOL
[4]  
[Anonymous], 2015, J Adv Comput Res
[5]  
[Anonymous], SIGNAL IMAGE VIDEO P
[6]  
[Anonymous], ARAB J GEOSCI
[7]   A comparison among different techniques for human ERG signals processing and classification [J].
Barraco, R. ;
Adorno, D. Persano ;
Brai, M. ;
Tranchina, L. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01) :86-95
[8]  
Barraco R, 2007, IFMBE PROC, V16, P919
[9]   Non-linear Poincare analysis of respiratory efforts in sleep apnea [J].
Behbahani, S. ;
Moridani, M. K. .
BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2015, 116 (07) :426-432
[10]   Prediction of epileptic seizures based on heart rate variability [J].
Behbahani, Soroor ;
Dabanloo, Nader Jafarnia ;
Nasrabadi, Ali Motie ;
Dourado, Antonio .
TECHNOLOGY AND HEALTH CARE, 2016, 24 (06) :795-810