Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate: a numerical study

被引:106
作者
Hameury, S [1 ]
机构
[1] Royal Inst Technol, Div Bldg Mat, Dept Civil & Architectural Engn, KTH, SE-10044 Stockholm, Sweden
关键词
massive wood wall; moisture transport; heat transport; indoor climate; moisture buffering capacity;
D O I
10.1016/j.buildenv.2004.10.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper introduces a hygrothermal model accounting for the moisture and heat transport in a massive wood envelope directly exposed to an indoor climate. A better knowledge of the passive interaction between an indoor climate and a heavy timber structure could lead to presenting an alternative to high air exchange rate, and to increasing the thermal comfort of the inhabitants. So far, the model is developed as a stand-alone application with a finite difference method, and is written in a Neutral Model Format, enabling a later implementation in a modular environment for indoor climate energy calculations, called IDA ICE. A numerical simulation is provided to depict the buffering capacity of a massive timber structure as a function of the air exchange rate and the effective wood wall area. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1400 / 1412
页数:13
相关论文
共 35 条
[1]  
AKANDER J, 2002, EFFECTIVE HEAT CAPAC
[2]  
[Anonymous], WISSENSCHAFTLICHEN G
[3]  
[Anonymous], 1999, FPLGTR113 US DEP AGR
[4]  
Hailwood A.J., 1946, T FARADAY SOC, V42, P84, DOI DOI 10.1039/TF946420B084
[5]  
HAKANSSON H, 1993, TABK981012 LUND U
[6]   Contribution of indoor exposed massive wood to a good indoor climate:: in situ measurement campaign [J].
Hameury, S ;
Lundström, T .
ENERGY AND BUILDINGS, 2004, 36 (03) :281-292
[7]  
HAMEURY S, 2004, P 8 WORLD C TIMB E N
[8]  
KALAMEES T, 2003, HYGROTHERMAL CALCULA, V38
[9]  
KOLMANN FFP, 1968, PRINCIPLES WOOD SCI, V1
[10]  
Luikov A.V, 1966, HEAT MASS TRANSFER C