Long-term surveillance of air quality in medical center operating rooms

被引:95
|
作者
Wan, Gwo-Hwa [2 ]
Chung, Feng-Fang [3 ]
Tang, Chin-Sheng [1 ]
机构
[1] Fu Jen Catholic Univ, Dept Publ Hlth, Coll Med, Sinjhuang City 242, Taipei County, Taiwan
[2] Chang Gung Univ, Dept Resp Care, Coll Med, Tao Yuan, Taiwan
[3] Chang Gung Inst Technol, Dept Nursing, Tao Yuan, Taiwan
关键词
Nosocomial infection; hospital indoor air; particulate matter; carbon dioxide; bioaerosol; CONTAMINATION; INFECTION; THEATERS; REPLACEMENT; POLLUTION; SURGERY; JOINT; HIP;
D O I
10.1016/j.ajic.2010.07.006
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Maintenance of adequate indoor air quality (IAQ) in operating rooms (ORs) is critical to the prevention of nosocomial infection in hospitalized patients. This study evaluated the characteristics of IAQ in various ORs in a medical center. Methods: Air temperature, relative humidity, carbon dioxide (CO2), particulate matter (PM), and bacterial concentrations were monitored in the ORs, and monthly variations were noted. Results: The mean CO2 concentrations in the ORs were lower than the suggested level (600 ppm average over 8 hours) set by Taiwan's Environmental Protection Agency. Positive relationships were found among the number of persons, temperature (Spearman's rho coefficient [r(s)] = 0.19; P<.01), and CO2 concentration (r(s) = 0.34; P<.01) in the OR. Bacterial concentration was significantly associated with PM level when adjusted for OR category and the number of persons in the room. Gram-positive bacteria (eg, Bacillus spp, Micrococcus spp, Staphylococcus spp) were frequently found in the monitored ORs. Conclusion: The IAQ in the ORs varied significantly from month to month. The number of persons in the OR affected IAQ, and a decreased PM level might indicate reduced microbial contamination in the OR.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [1] Aerosol Distribution During Open Suctioning and Long-Term Surveillance of Air Quality in a Respiratory Care Center Within a Medical Center
    Chung, Fen-Fang
    Lin, Hui-Ling
    Liu, Hsueh-Erh
    Lien, Angela Shin-Yu
    Hsiao, Hsiu-Feng
    Chou, Lan-Ti
    Wan, Gwo-Hwa
    RESPIRATORY CARE, 2015, 60 (01) : 30 - 37
  • [2] Forced-Air Warming Does Not Worsen Air Quality in Laminar Flow Operating Rooms
    Sessler, Daniel I.
    Olmsted, Russell N.
    Kuelpmann, Ruediger
    ANESTHESIA AND ANALGESIA, 2011, 113 (06) : 1416 - 1421
  • [3] Effect of ventilation rate on the optimal air quality of trauma and colorectal operating rooms
    Liang, Ching-Chieh
    Wu, Feng-Jen
    Chien, Tsung-Yi
    Lee, Shih-Tseng
    Chen, Chi-Tsung
    Wang, Chi
    Wan, Gwo-Hwa
    BUILDING AND ENVIRONMENT, 2020, 169
  • [4] Long-term changes in air quality. The case of Pristina (Kosovo)
    Shala, Shkumbin
    Aleksander-Kwaterczak, Urszula
    Rexhepi, Fatos
    GEOLOGY GEOPHYSICS AND ENVIRONMENT, 2022, 48 (01): : 5 - 18
  • [5] An ensemble multi-scale framework for long-term forecasting of air quality
    Jiang, Shan
    Yu, Zu-Guo
    Anh, Vo V.
    Lee, Taesam
    Zhou, Yu
    CHAOS, 2024, 34 (01)
  • [6] Long-term air quality study by DOAS within Beijing
    Schaefer, Klaus
    Wang, Yuesi
    Xin, Jinyuan
    Ling, Hong
    Suppan, Peter
    REMOTE SENSING OF CLOUDS AND THE ATMOSPHERE XV, 2010, 7827
  • [7] Air Quality Monitoring of the Post-Operative Recovery Room and Locations Surrounding Operating Theaters in a Medical Center in Taiwan
    Tang, Chin-Sheng
    Wan, Gwo-Hwa
    PLOS ONE, 2013, 8 (04):
  • [8] Larger operating rooms have better air quality than smaller rooms in primary total knee arthroplasty
    Shen, Michelle
    Sicat, Chelsea Sue
    Schwarzkopf, Ran
    Slover, James D.
    Bosco III, Joseph A.
    Rozell, Joshua C.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (10) : 6335 - 6338
  • [9] Larger operating rooms have better air quality than smaller rooms in primary total knee arthroplasty
    Michelle Shen
    Chelsea Sue Sicat
    Ran Schwarzkopf
    James D. Slover
    Joseph A. Bosco
    Joshua C. Rozell
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 6335 - 6338
  • [10] Diagnosis of indoor air contaminants in a daycare center using a long-term monitoring
    Kim, Chul
    Choi, Doowon
    Lee, Yun Gyu
    Kim, Kichul
    BUILDING AND ENVIRONMENT, 2021, 204