A DNA sequence-specific electrochemical biosensor based on alginic acid-coated cobalt magnetic beads for the detection of E. coli

被引:52
作者
Geng, Ping [2 ]
Zhang, Xinai [2 ]
Teng, Yingqiao [2 ]
Fu, Ying [2 ]
Xu, Lili [2 ]
Xu, Min [1 ]
Jin, Litong [2 ]
Zhang, Wen [2 ]
机构
[1] E China Normal Univ, Dept Phys, Shanghai Key Lab Magnet Resonance, Shanghai 200062, Peoples R China
[2] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
关键词
DNA electrochemical biosensor; Magnetic beads; Hybridization detection; E; coli; ESCHERICHIA-COLI; DRINKING-WATER; COLIFORMS; NANOPARTICLES; BACTERIA; TYROSINASE;
D O I
10.1016/j.bios.2011.01.007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new type of DNA sequence-specific electrochemical biosensor based on magnetic beads for the detection of Escherichia coli is reported in the present work. Alginic acid-coated cobalt magnetic beads, capped with 5'-(NH2) oligonucleotide and employed not only for magnetic separation but also as the solid adsorbent, were used as DNA probes to hybridize with the target E. coli DNA sequence. This assay was specific for E. coli detection depending on the uid A gene, which encodes for the enzyme beta-D-glucuronidase produced by E. coli strains. When daunomycin (DNR) was used as DNA hybridization indicator, the target sequences of E. coli hybridized with the probes resulted in the decrease of DNR reduction peak current, which was proportional to the E. coli concentration. The optimization of the hybridization detection was carried out and the specificity of the probes was also demonstrated. This DNA biosensor can be employed to detect a complementary target sequence for 3.0 x 10(-10) mol/L and denatured PCR products for 0.5 ng/mu L. The linear range of the developed biosensor for the detection of E. coli cells was from 1.0 x 10(2) to 2.0 x 10(3) cells/mL with a detection limit of 50 cells/mL After a brief enrichment process, a concentration of 10 cells/mL E. coli in real water samples was detected by the electrochemical biosensor. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3325 / 3330
页数:6
相关论文
共 28 条
[1]   Escherichia coli genosensor based on polyaniline [J].
Arora, Kavita ;
Prabhakar, Nirmal ;
Chand, Subhash ;
Malhotra, B. D. .
ANALYTICAL CHEMISTRY, 2007, 79 (16) :6152-6158
[2]   DETECTION OF ESCHERICHIA-COLI AND SHIGELLA SPP IN WATER BY USING THE POLYMERASE CHAIN-REACTION AND GENE PROBES FOR UID [J].
BEJ, AK ;
DICESARE, JL ;
HAFF, L ;
ATLAS, RM .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (04) :1013-1017
[3]   Enhanced detection of live bacteria using a dendrimer thin film in an optical biosensor [J].
Chang, AC ;
Gillespie, JB ;
Tabacco, MB .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :467-470
[4]   Functional Nanoparticle-Based Proteomic Strategies for Characterization of Pathogenic Bacteria [J].
Chen, Wei-Jen ;
Tsai, Pei-Jane ;
Chen, Yu-Chie .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9612-9621
[5]   A sensitive DNA electrochemical biosensor based on magnetite with a glassy carbon electrode modified by muti-walled carbon nanotubes in polypyrrole [J].
Cheng, GF ;
Zhao, J ;
Tu, YH ;
He, PA ;
Fang, YH .
ANALYTICA CHIMICA ACTA, 2005, 533 (01) :11-16
[6]  
Clesceri L, 1998, STANDARD METHODS EXA
[7]   Using PCR amplification to increase the confidence level of Salmonella typhimurium DNA microarray chip hybridization [J].
Courtney, Shannon ;
Mossoba, Miriam E. ;
Hammack, Thomas S. ;
Keys, Christine ;
Al-Khaldi, Sutian F. .
MOLECULAR AND CELLULAR PROBES, 2006, 20 (3-4) :163-171
[8]   Micromechanical oscillators as rapid biosensor for the detection of active growth of Escherichia coli [J].
Gfeller, KY ;
Nugaeva, N ;
Hegner, M .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (03) :528-533
[9]   Medical application of functionalized magnetic nanoparticles [J].
Ito, A ;
Shinkai, M ;
Honda, H ;
Kobayashi, T .
JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2005, 100 (01) :1-11
[10]   Antimicrobial peptides for detection of bacteria in biosensor assays [J].
Kulagina, NV ;
Lassman, ME ;
Ligler, FS ;
Taitt, CR .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6504-6508