Cardiac filling volumes versus pressures for predicting fluid responsiveness after cardiovascular surgery: the role of systolic cardiac function

被引:36
作者
Trof, Ronald J. [1 ,2 ]
Danad, Ibrahim [1 ]
Reilingh, Mikel W. L. [1 ]
Breukers, Rose-Marieke B. G. E. [1 ]
Groeneveld, A. B. Johan [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Intens Care, NL-1081 HV Amsterdam, Netherlands
[2] Med Spectrum Twente, Dept Intens Care, NL-7513 ER Enschede, Netherlands
来源
CRITICAL CARE | 2011年 / 15卷 / 01期
关键词
CENTRAL VENOUS-PRESSURE; MECHANICALLY VENTILATED PATIENTS; INTRATHORACIC BLOOD-VOLUME; END-DIASTOLIC VOLUME; STROKE VOLUME; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; WEDGE PRESSURE; PRELOAD; THERMODILUTION; INDICATOR;
D O I
10.1186/cc10062
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Static cardiac filling volumes have been suggested to better predict fluid responsiveness than filling pressures, but this may not apply to hearts with systolic dysfunction and dilatation. We evaluated the relative value of cardiac filling volume and pressures for predicting and monitoring fluid responsiveness, according to systolic cardiac function, estimated by global ejection fraction (GEF, normal 25 to 35%) from transpulmonary thermodilution. Methods: We studied hypovolemic, mechanically ventilated patients after coronary (n = 18) or major vascular (n = 14) surgery in the intensive care unit. We evaluated 96 colloid fluid loading events (200 to 600 mL given in three consecutive 30-minute intervals, guided by increases in filling pressures), divided into groups of responding events (fluid responsiveness) and non-responding events, in patients with low GEF (< 20%) or near-normal GEF (>= 20%). Patients were monitored by transpulmonary dilution and central venous (n = 9)/pulmonary artery (n = 23) catheters to obtain cardiac index (CI), global end-diastolic volume index (GEDVI), central venous (CVP) and pulmonary artery occlusion pressure (PAOP). Results: Fluid responsiveness occurred in 8 (>= 15% increase in CI) and 17 (>= 10% increase in CI) of 36 fluid loading events when GEF was < 20%, and 7 (>= 15% increase in CI) and 17 (>= 10% increase in CI) of 60 fluid loading events when GEF was = 20%. Whereas a low baseline GEDVI predicted fluid responsiveness particularly when GEF was >= 20% (P = 0.002 or lower), a low PAOP was of predictive value particularly when GEF was < 20% (P = 0.004 or lower). The baseline CVP was lower in responding events regardless of GEF. Changes in CVP and PAOP paralleled changes in CI particularly when GEF was < 20%, whereas changes in GEDVI paralleled CI regardless of GEF. Conclusions: Regardless of GEF, CVP may be useful for predicting fluid responsiveness in patients after coronary and major vascular surgery provided that positive end-expiratory pressure is low. When GEF is low (< 20%), PAOP is more useful than GEDVI for predicting fluid responsiveness, but when GEF is near-normal (>= 20%) GEDVI is more useful than PAOP. This favors predicting and monitoring fluid responsiveness by pulmonary artery catheter-derived filling pressures in surgical patients with systolic left ventricular dysfunction and by transpulmonary thermodilution-derived GEDVI when systolic left ventricular function is relatively normal.
引用
收藏
页数:11
相关论文
共 33 条
[1]  
[Anonymous], COCHRANE DATABASE SY
[2]  
Breukers RMBGE, 2009, YEARB INTENSIVE CARE, P265, DOI 10.1007/978-3-540-92276-6_25
[3]   Assessing fluid responses after coronary surgery: role of mathematical coupling of global end-diastolic volume to cardiac output measured by transpulmonary thermodilution [J].
Breukers, Rose-Marieke B. G. E. ;
de Wilde, Rob B. P. ;
van den Berg, Paul C. M. ;
Jansen, Jos R. C. ;
Faes, Theo J. C. ;
Twisk, Jos W. R. ;
Groeneveld, A. B. Johan .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (11) :954-960
[4]   Relative value of pressures and volumes in assessing fluid responsiveness after valvular and coronary artery surgery [J].
Breukers, Rose-Marieke B. G. E. ;
Trof, Ronald J. ;
de Wilde, Rob B. P. ;
van den Berg, Paul C. M. ;
Twisk, Jos W. R. ;
Jansen, Jos R. C. ;
Groeneveld, Johan .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (01) :62-68
[5]  
Brock H, 2002, EUR J ANAESTH, V19, P288
[6]   ECHOCARDIOGRAPHIC AND HEMODYNAMIC INDEXES OF LEFT-VENTRICULAR PRELOAD IN PATIENTS WITH NORMAL AND ABNORMAL VENTRICULAR-FUNCTION [J].
CHEUNG, AT ;
SAVINO, JS ;
WEISS, SJ ;
AUKBURG, SJ ;
BERLIN, JA .
ANESTHESIOLOGY, 1994, 81 (02) :376-387
[7]   Estimation of left ventricular systolic function by single transpulmonary thermodilution [J].
Combes, A ;
Berneau, JB ;
Luyt, CE ;
Trouillet, JL .
INTENSIVE CARE MEDICINE, 2004, 30 (07) :1377-1383
[8]   END-DIASTOLIC VOLUME VERSUS PULMONARY-ARTERY WEDGE PRESSURE IN EVALUATING CARDIAC PRELOAD IN TRAUMA PATIENTS [J].
DIEBEL, L ;
WILSON, RF ;
HEINS, J ;
LARKY, H ;
WARSOW, K ;
WILSON, S .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1994, 37 (06) :950-955
[9]   Assessment of ventricular function in critically ill patients: Limitations of pulmonary artery catheterization [J].
Fontes, ML ;
Bellows, W ;
Ngo, L ;
Mangano, DT .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (05) :521-527
[10]   Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water, and liver function [J].
Godje, O ;
Peyerl, M ;
Seebauer, T ;
Dewald, O ;
Reichart, B .
CHEST, 1998, 113 (04) :1070-1077