Lightning Overvoltage Investigation due to a Backflashover Event in Transmission Lines: a realist modeling proposal

被引:0
|
作者
Rodrigues, Andre Roger [1 ]
Boaventura, Wallace do Couto [2 ]
Guimaraes, Geraldo Caixeta [3 ]
Caixeta, Daniel Araujo [3 ]
Ribeiro Chaves, Marcelo Lynce [3 ]
Tamashiro, Marcio Augusto [4 ]
机构
[1] IFMG Fed Inst Minas Gerais, Formiga, Brazil
[2] UFMG Fed Univ Minas Gerais, Belo Horizonte, MG, Brazil
[3] UFU Fed Univ Uberlandia, Uberlandia, MG, Brazil
[4] IFTO Fed Inst Tocantins, Palmas, Brazil
来源
2015 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIII SIPDA) | 2015年
关键词
backflashover; insulation coordination; leader progression model; lightning performance; transmission lines;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a study about the lightning performance of transmission lines using advanced electromagnetic models to perform a realistic representation of the first stroke current. Based on the measurement data obtained at the Morro do Cachimbo/MG Station, it was possible to synthesize first stroke current waveforms with single-an double-peak in a realistic way. In addition, the investigation involves an analysis with a model implemented in ATP-Models to reproduce the first stroke current recommended by CIGRE methodology. The breakdown process was represented through a Leader Progression Model able to represent accurately the physical process established along the perimeter of the insulator strings, during a backflashover event. The results allowed an investigation of the waveforms and amplitudes of the resulting overvoltages across the insulators. The computational modeling developed permits to identify the amplitude of the overvoltage that produces the backflashover and the instant of time that the breakdown occurs.
引用
收藏
页码:231 / 238
页数:8
相关论文
共 50 条
  • [31] Investigation on Lightning Attractive Width of Transmission Lines: Experimental Studies
    Disyadej, T.
    Grzybowski, S.
    2010 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: SMART SOLUTIONS FOR A CHANGING WORLD, 2010,
  • [32] Thailand experiences in overvoltage analysis and events in electric power transmission system due to switching and lightning surges
    Dumronggittigule, S.
    Ngamsanroaj, K.
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 3066 - +
  • [33] Investigation of the Lightning Behavior of Transmission Lines with the Aim of Evaluating Their Reliability.
    Cecchi, Givlano
    Dellera, Luigi
    Garbagnati, Emilio
    Energia Elettrica, 1988, 65 (02): : 67 - 75
  • [34] Modeling electromagnetic field radiated by lightning coupling to overhead transmission lines
    M'ziou, Nassima
    Mokhnache, Leila
    Boubakeur, Ahmed
    CONFERENCE RECORD OF THE 2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 2008, : 59 - +
  • [35] A cascade of tapered transmission lines for the lightning return-stroke modeling
    Amoruso, V
    Lattarulo, F
    ELECTROMAGNETIC COMPATIBILITY 1999, 1999, : 587 - 592
  • [36] Recommendations related to the Peak-current distributions in studies of lightning performance of transmission lines based on the range of critical currents associated with Backflashover
    Silveira, Fernando H.
    Almeida, Frederico S.
    Visacro, Silverio
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 236
  • [37] Modelling Transient Response of Nonuniform Transmission Lines Due to Nearby Lightning Strikes
    Gunawardana, Manuja
    Kordi, Behzad
    2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA), 2021,
  • [38] The Analysis of Transient Phenomena on Power Transmission Lines Due to Lightning Electromagnetic Pulses
    Cakil, Turan
    Carlak, H. Feza
    Ozen, Sukru
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 3000 - 3005
  • [39] Calculation of overvoltage on nearby underground metal pipeline due to the lightning strike on UHV AC transmission line tower
    Qi, Lei
    Yuan, Hui
    Wu, Yan
    Cui, Xiang
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 94 : 54 - 63
  • [40] Effect of Concentrated Tower Grounding System Modeling on the Minimum Backflashover Current and BFR of 150 and 400 kV Overhead Transmission Lines
    Datsios, Z. G.
    Mikropoulos, P. N.
    Tsovilis, T. E.
    Angelakidou, S. I.
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,